Inspections for the day of: Friday, September 6, 2019.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-02945 Electrical Rough-In9/6/20199/6/20199/6/2019 3:48:44 PMPPASS
Ceiling Cover Phone #: ###-#### Inspection requested via web by David Feller Grid rough in ok cover
ELE19-03349 Permanent Service9/6/20199/6/20199/6/2019 2:38:06 PMPPASS
MITCH- PLEASE CALL 30 MIN PRIOR Phone #: ###-####
Service to be energized on a temporary basis. New meter base and mast at this time, will be correcting issues with too many current carrying conductors in surface conduits ect.
p/s o/h rec ok
ELE19-02312 Final9/6/20199/6/20199/6/2019 2:35:38 PMPPASS
Phone #: ###-#### Inspection requested via web by Tyler Bowen Final ok
ELE19-02841 Final9/6/20199/6/20199/6/2019 1:52:00 PMPFAIL
Final inspection please. Thank you! Phone #: ###-#### Inspection requested via web by Kyle Lott
300.15- All cables shall terminate in a box. Upstairs MC up thru floor with 5' of loose wire and open stripped ends exposed.
314.25- All boxes shall have covers. Open junction box in ceiling against wall. Open switch box
330.30- MC shall be secured with in 12" of a box. Couple locations.
ELE17-03140 Final9/5/20199/6/20199/6/2019 1:10:48 PMAFAIL
Duane Oreilly is contact at ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce
314.25- All boxes shall have covers.
330.30- MN cable shall be secured with in 12" of a box.
Building permit noted some areas of grid being replaced. History of inspections show no grid inspection performed. Just in from front door looked up and noticed 2 open boxes and KO seals needed and unsecured MC cable.
Will need to meet contact on site with ladder to check areas above grid.
ELE19-03212 Permanent Service9/6/20199/6/20199/6/2019 11:40:55 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn
Contractor failed to include permenant service in inspection request. Inspector 345 inspected and stickered meter base on 9-3-19. Confirmed sticker posted.
ELE19-02011 Final9/5/20199/6/20199/6/2019 11:29:23 AMAPASS
garage code 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
ELE19-02994 Permanent Service9/5/20199/6/20199/6/2019 10:44:46 AMAFAIL
this is a service inspection. Padlock #2914. Any questions feel free to call Jason at ###-#### Phone #: ###-#### Inspection requested via web by Sherry Allen
250.24- AC system shall have a grounding electrode conductor connected to the grounded conductor. Unable to verify grounding electrode and main bonding jumper missing to bond grounded conductor.
ELE18-01935 Final9/5/20199/6/20199/6/2019 10:16:43 AMAPART
Final inspection for units 206, 207, and 209
Contact electrician on-site John McElroy (Homey)
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Units noted signed off in office. TCO ok
ELE19-03174 Electrical Rough-In9/5/20199/6/20199/6/2019 9:32:38 AMAPASS
Phone #: ###-#### Inspection requested via web by Jeremy Cloud
Back kitchen wall changing. Walls and soffits and bathrooms as noted on contractor print rough in ok cover.
ELE19-02825 Final9/5/20199/6/20199/6/2019 9:07:08 AMAPASS
jose Phone #: ###-#### Final ok
ELE18-03625 Final9/5/20199/6/20199/6/2019 7:24:50 AMACANC
Please give me half an hour notice before inspection to insure access. Thank you Shaun ###-#### Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Inspection cancelled from web by: Shaun Kirkman