ELE11-01976
| ELE-Aging Inspection | 10/17/2018 | 10/17/2018 | 10/18/2018 8:15:34 AM | | FAIL |
|
|
No activity and no attempt to final
|
ELE18-03828
| Final | 10/17/2018 | 10/17/2018 | 10/17/2018 2:44:13 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Perez Final ok
|
ELE18-01391
| Electrical Rough-In | 10/16/2018 | 10/17/2018 | 10/17/2018 2:11:26 PM | P | PASS |
|
|
Rough in wall inspection level 3 area A. Phone #: ###-#### Inspection requested via web by Tom Betty Area "A" walls only As marked on print ok to cover
|
ELE18-03980
| Temporary Service | 10/17/2018 | 10/17/2018 | 10/17/2018 1:17:33 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
|
ELE18-01206
| Electrical Rough-In | 10/17/2018 | 10/17/2018 | 10/17/2018 12:45:23 PM | P | PASS |
|
|
Please call Bobby for inspection of 1st floor area C walls. Also please call Chris for underground inspection of site lighting on north end of the building. Thanks. Phone #: ###-#### Inspection requested via web by Rafael Castillo Area listed walls and underground only ok to cover
|
ELE18-03855
| Rough-In Permanent Service | 10/16/2018 | 10/17/2018 | 10/17/2018 12:05:45 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn rough in ok p/s u/g n ok
|
ELE18-03512
| Rough-In Permanent Service | 10/16/2018 | 10/17/2018 | 10/17/2018 12:05:05 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn rough in ok p/s u/g n ok
|
ELE18-03545
| Final | 10/16/2018 | 10/17/2018 | 10/17/2018 11:14:36 AM | A | FAIL |
|
|
If front door is locked, there is a lock box on front door with a code of 1975. If you have any issues please give me a call. Thanks Phone #: ###-#### Inspection requested via web by Jason Scott 210.8 Receps within 6ft of a sink shall be GFCI protected.
|
ELE18-02156
| Electrical Rough-In | 10/17/2018 | 10/17/2018 | 10/17/2018 11:00:14 AM | A | PASS |
|
|
ceiling inspection Phone #: ###-#### Inspection requested via web by Ron Zimmerman phase 2 ceilings only ok to cover
|
ELE18-03306
| Electrical Rough-In | 10/16/2018 | 10/17/2018 | 10/17/2018 10:44:42 AM | A | PASS |
|
|
Ceiling inspection - Contact is Andy Chambers Phone #: ###-#### Inspection requested via web by Scott Campbell Ceiling only ok to cover
|
ELE18-03635
| Electrical Rough-In | 10/16/2018 | 10/17/2018 | 10/17/2018 10:14:16 AM | A | PASS |
|
|
It is for the addition. It is open. If you have any questions please feel free to contact Tony ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Job foam sealed prior to inspection. Rough in addition only ok to cover
|
ELE18-03830
| Permanent Service | 10/16/2018 | 10/17/2018 | 10/17/2018 9:59:28 AM | A | PASS |
|
|
Brandon Greeson is contact at ###-#### Phone #: ###-#### Inspection requested via web by Debby Pierce p/s u/g n ok
|
ELE18-02072
| Electrical Rough-In | 10/16/2018 | 10/17/2018 | 10/17/2018 9:38:33 AM | A | PASS |
|
|
Joe-ceiling cover Phone #: ###-#### Ceiling only ok to cover
|
ELE18-03590
| Final | 10/16/2018 | 10/17/2018 | 10/17/2018 9:23:49 AM | A | PART |
|
|
Ceiling/Partial Final for the Servery at the B17C Cafeteria. Contact Pierre Elskamp. Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Patial final servery only ok to cover
|
ELE18-03969
| Electrical Rough-In | 10/16/2018 | 10/17/2018 | 10/16/2018 1:19:49 PM | A | PASS |
|
|
Inspection requested via web by Garrett Collins Sunroom, laundry, powder bath and down bed bath ok to cover
|