Inspections for the day of: Wednesday, October 24, 2018.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-03614 Final10/24/201810/24/201810/24/2018 2:16:09 PMPPASS
Any Questions please call Louis at ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller hot tub only final ok
ELE18-01206 Permanent Service10/24/201810/24/201810/24/2018 1:33:56 PMPCANC
Please call Chris to discuss permanent power inspection. Thanks. Phone #: ###-#### Inspection requested via web by Rafael Castillo
ELE18-01206 Conference10/24/201810/24/201810/24/2018 1:33:39 PMPDONE
Please call Chris to discuss permanent power inspection. Thanks. Phone #: ###-#### Inspection requested via web by Rafael Castillo Talked about requirments of 230.95C. On site preformance testing. 110.26C3 Personel doors and hardware.( Panic hardware not reequired for perm service but shall be installed as soon as possible. No final without hardware in place.)
ELE18-02072 Final10/24/201810/24/201810/24/2018 12:54:44 PMPPART
Aaron Phone #: ###-#### 400.12 Cords shall not pass through dropped ceiling.( 2 TV's in front lobby)
ELE18-01391 Electrical Rough-In10/23/201810/24/201810/24/2018 11:59:04 AMAPASS
Call Scott for level 3 therapist work room rough in walls inspection. Phone #: ###-#### Inspection requested via web by Tom Betty As marked on print ok to cover
ELE18-03730 Conference10/23/201810/24/201810/24/2018 11:31:50 AMAPASS
Please contact Ron Pontius upon arrival at the B26 lobby Phone #: ###-#### Inspection requested via web by Ron Pontius Discussed running PVC coated MC in Metal wireway. Discussed bonding of raceway and weather tight entrance into transformer.
ELE18-04091 Final10/23/201810/24/201810/24/2018 11:30:20 AMAPASS
Final inspection for Fisher''s Tenant Improvement Phone #: ###-#### Inspection requested via web by Kevin Perez Final ok
ELE18-02000 Final10/23/201810/24/201810/24/2018 11:20:04 AMAPASS
Phone #: ###-#### Inspection requested via web by Jerry Moore corrections made final ok
ELE18-02715 Final10/23/201810/24/201810/24/2018 10:53:21 AMAPASS
Please call Ron when you arrive on site. The B26 lobby is the closest to the B29 job site. Phone #: ###-#### Inspection requested via web by Ron Pontius Final ok
ELE18-02216 Electrical Rough-In10/23/201810/24/201810/24/2018 10:51:25 AMAPASS
Thank you. Phone #: ###-#### Inspection requested via web by CHRIS CARMINE Remaining wall in conference room ok to cover
ELE18-04069 Electrical Rough-In10/23/201810/24/201810/24/2018 9:01:28 AMACANC
still changing out the main breaker and need something from you to reconnect Phone #: ###-#### Inspection requested via web by Andy Derrick Needed perm serv
ELE18-04069 Permanent Service10/24/201810/24/201810/24/2018 9:01:04 AMAPASS
still changing out the main breaker and need something from you to reconnect Phone #: ###-#### Inspection requested via web by Andy Derrick Breaker changed from 200A to 175A. p/s u/g rec ok
ELE18-04069 Final10/22/201810/24/201810/23/2018 10:53:39 AMAFAIL
Idaho Power will pull the meter at 9am so I can change the main breaker. It won''t take me long (20 minutes) and I''ll be leaving. Everything else is done now. Idaho Power might hang out and re-energize without your sticker, depends on the guy. Phone #: ###-#### Inspection requested via web by Andy Derrick No ispections done on solar array. No permit covering electrical from array.