Inspections for the day of: Friday, November 22, 2019.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-04498 Temporary Service11/22/201911/22/201911/25/2019 6:20:59 AMPPASS
Phone #: ###-#### Inspection requested via web by Bonnie Page t/s u/g n ok
ELE19-04543 Rough-In Permanent Service11/22/201911/22/201911/22/2019 1:39:31 PMAPASS
Phone #: ###-#### Inspection requested via web by Bonnie Page ROugh in ok p/s u/g n ok
ELE19-04397 Conference11/21/201911/22/201911/22/2019 1:15:16 PMPPASS
Was asked to schedule conference with Electrical Inspector before I do any finish work, would like to schedule for after 2:00 pm if possible. Please call before heading to house. Phone #: ###-#### Inspection requested via web by JEFFREY DAVIS Spoke to owner over the phone. Rough in was done by licensed contractor and aproved for cover. Owner will trim devices. Informed him that tamper resistant receps are required. Also will need a secondary conference when exhisting kitchen is demo. Need to go over scope of work, circuitry and wall spacing. Recomended owner get "Homeowner handout" From City Hall prior to conference.
ELE19-02917 Final11/21/201911/22/201911/22/2019 12:39:31 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk Corrections made final ok
ELE19-03862 Final11/22/201911/22/201911/22/2019 12:28:20 PMPFAIL
back door is open, can go through fence on the side of home Phone #: ###-#### Inspection requested via web by Andy Duckett 314.20 Extension rings needed where boxes set back 1/4in (Devices in tung and groove) 210.8 GFCI protection shal be readily accessible. (Kitchen GFCI behind refer) 110.26A2 Work space shall be 30in measured from edge of panel. (Spoke to cantractor at rough in. Countertop was not going to be installed) Recep for micro needs installed completely and missing plate.
ELE19-03420 Electrical Rough-In11/21/201911/22/201911/22/2019 11:27:42 AMAPASS
Jose Phone #: ###-#### Back office area in phase 3 Ceiling only ok to cover
ELE19-04517 Final11/21/201911/22/201911/22/2019 11:10:38 AMPCANC
Please try and call me with as much heads up as possible thank you Phone #: ###-#### Inspection requested via web by TRENT Swaim
ELE19-04517 Electrical Rough-In11/22/201911/22/201911/22/2019 11:10:23 AMPPASS
Please try and call me with as much heads up as possible thank you Phone #: ###-#### Inspection requested via web by TRENT Swaim Listing only ok
ELE19-02770 Final11/22/201911/22/201911/22/2019 10:44:34 AMAPASS
garage code 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn final ok
ELE19-01784 Final11/21/201911/22/201911/22/2019 10:01:15 AMAPART
Mark Phone #: ###-#### Corrections have been made.. Panel schedules need completed and AFCI placard installed for Final. Temp final only ok
ELE19-04110 Rough-In Permanent Service11/22/201911/22/201911/22/2019 9:55:46 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Bob Glenn Inspection cancelled from web by: Bob Glenn
ELE19-02938 Temporary Service11/21/201911/22/201911/22/2019 9:41:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
ELE19-04414 Final11/21/201911/22/201911/22/2019 9:12:32 AMAPASS
Phone #: ###-#### Inspection requested via web by Thomas wilson final ok
ELE19-04533 Rough-In Permanent Service11/21/201911/22/201911/22/2019 8:52:49 AMAPASS
Phone #: ###-#### Inspection requested via web by Greg Traudt rough in ok p/s u/g n ok