ELE19-04498
| Temporary Service | 11/22/2019 | 11/22/2019 | 11/25/2019 6:20:59 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bonnie Page t/s u/g n ok
|
ELE19-04543
| Rough-In Permanent Service | 11/22/2019 | 11/22/2019 | 11/22/2019 1:39:31 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bonnie Page ROugh in ok p/s u/g n ok
|
ELE19-04397
| Conference | 11/21/2019 | 11/22/2019 | 11/22/2019 1:15:16 PM | P | PASS |
|
|
Was asked to schedule conference with Electrical Inspector before I do any finish work, would like to schedule for after 2:00 pm if possible. Please call before heading to house. Phone #: ###-#### Inspection requested via web by JEFFREY DAVIS Spoke to owner over the phone. Rough in was done by licensed contractor and aproved for cover. Owner will trim devices. Informed him that tamper resistant receps are required. Also will need a secondary conference when exhisting kitchen is demo. Need to go over scope of work, circuitry and wall spacing. Recomended owner get "Homeowner handout" From City Hall prior to conference.
|
ELE19-02917
| Final | 11/21/2019 | 11/22/2019 | 11/22/2019 12:39:31 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Corrections made final ok
|
ELE19-03862
| Final | 11/22/2019 | 11/22/2019 | 11/22/2019 12:28:20 PM | P | FAIL |
|
|
back door is open, can go through fence on the side of home Phone #: ###-#### Inspection requested via web by Andy Duckett 314.20 Extension rings needed where boxes set back 1/4in (Devices in tung and groove) 210.8 GFCI protection shal be readily accessible. (Kitchen GFCI behind refer) 110.26A2 Work space shall be 30in measured from edge of panel. (Spoke to cantractor at rough in. Countertop was not going to be installed) Recep for micro needs installed completely and missing plate.
|
ELE19-03420
| Electrical Rough-In | 11/21/2019 | 11/22/2019 | 11/22/2019 11:27:42 AM | A | PASS |
|
|
Jose Phone #: ###-#### Back office area in phase 3 Ceiling only ok to cover
|
ELE19-04517
| Final | 11/21/2019 | 11/22/2019 | 11/22/2019 11:10:38 AM | P | CANC |
|
|
Please try and call me with as much heads up as possible thank you Phone #: ###-#### Inspection requested via web by TRENT Swaim
|
ELE19-04517
| Electrical Rough-In | 11/22/2019 | 11/22/2019 | 11/22/2019 11:10:23 AM | P | PASS |
|
|
Please try and call me with as much heads up as possible thank you Phone #: ###-#### Inspection requested via web by TRENT Swaim Listing only ok
|
ELE19-02770
| Final | 11/22/2019 | 11/22/2019 | 11/22/2019 10:44:34 AM | A | PASS |
|
|
garage code 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn final ok
|
ELE19-01784
| Final | 11/21/2019 | 11/22/2019 | 11/22/2019 10:01:15 AM | A | PART |
|
|
Mark Phone #: ###-#### Corrections have been made.. Panel schedules need completed and AFCI placard installed for Final. Temp final only ok
|
ELE19-04110
| Rough-In Permanent Service | 11/22/2019 | 11/22/2019 | 11/22/2019 9:55:46 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Bob Glenn Inspection cancelled from web by: Bob Glenn
|
ELE19-02938
| Temporary Service | 11/21/2019 | 11/22/2019 | 11/22/2019 9:41:41 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE19-04414
| Final | 11/21/2019 | 11/22/2019 | 11/22/2019 9:12:32 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Thomas wilson final ok
|
ELE19-04533
| Rough-In Permanent Service | 11/21/2019 | 11/22/2019 | 11/22/2019 8:52:49 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt rough in ok p/s u/g n ok
|