ELE19-03735
| Electrical Rough-In | 12/23/2019 | 12/23/2019 | 12/23/2019 2:25:35 PM | P | NR |
|
|
Gerald Phone #: ###-#### Missing power jumpers to Back door switch and U.C light switch. Missing switch legs to U.C light. Missing jumpers between cans R and L of fireplace.Missing jumper to Dish washer recep(Will be under sink not behind Dish washer) Missing Home run to hood location(Will re-use 8-2 to existing cooktop and re-breaker at 20A) All boxes will need made up before rough in.
|
ELE19-04166
| Final | 12/23/2019 | 12/23/2019 | 12/23/2019 1:50:00 PM | P | PASS |
|
|
call for access Phone #: ###-#### Inspection requested via web by Chris Berthelot final ok
|
ELE19-03981
| Final | 12/23/2019 | 12/23/2019 | 12/23/2019 1:16:48 PM | P | PASS |
|
|
garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk final ok
|
ELE19-04894
| Electrical Rough-In | 12/23/2019 | 12/23/2019 | 12/23/2019 12:42:14 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Perez Hall bath, Master bath. E Living rm wall, E Bonus rm wall ok. Kitchen layout stays the same Rough in ok
|
ELE19-04556
| Final | 12/20/2019 | 12/23/2019 | 12/23/2019 12:30:05 PM | A | PASS |
|
|
No rush can be am or on have a great day. House address is new it will be the small house in the back alley not the main house off of bannock thank you Phone #: ###-#### Inspection requested via web by TRENT Swaim final ok
|
ELE19-03744
| Final | 12/22/2019 | 12/23/2019 | 12/23/2019 10:14:43 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson 334.15B NM cable shall be protected. (Flex furnace)
|
ELE19-03743
| Final | 12/22/2019 | 12/23/2019 | 12/23/2019 10:13:49 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson 334.15B NM cable shall be protected. (Flex furnace)
|
ELE19-03742
| Final | 12/22/2019 | 12/23/2019 | 12/23/2019 10:12:49 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
|
ELE19-03998
| Final | 12/20/2019 | 12/23/2019 | 12/23/2019 10:00:50 AM | A | FAIL |
|
|
Call Darrius 30 minutes before arrival @ ###-#### so they can meet you there. Phone #: ###-#### Inspection requested via web by Winters LLC 210.70A2(1) At least 1 wall switch lighting outlet shall be provided at each outdoor enterance. 210.52E1 At least one outdoor recep shall be installed at grade level
|
ELE19-04863
| Rough-In Permanent Service | 12/20/2019 | 12/23/2019 | 12/23/2019 8:25:58 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt Corrections made rough in ok p/s u/g n ok
|