ELE15-03709
| ELE-Aging Inspection | 2/21/2019 | 2/21/2019 | 2/25/2019 10:16:47 AM | | DONE |
|
|
Spoke with receptionist. Job may be complete. Will call for inspection soon.
|
ELE18-01334
| Final | 2/21/2019 | 2/21/2019 | 2/21/2019 2:22:31 PM | P | FAIL |
|
|
please call 1 hour prior to the inspection at ###-#### Phone #: ###-#### Inspection requested via web by Vitaliy Berezin 210.8. All 120v receps ins a comercial kitchen shall be GFCI protected. 210.63. Service recep required for refridgeration equipment.(Outdoor walk in cooler)
|
ELE18-03251
| Final | 2/20/2019 | 2/21/2019 | 2/21/2019 1:36:07 PM | P | PASS |
|
|
Homeowners contact info Jodi ###-#### or John ###-#### Phone #: ###-#### Inspection requested via web by Emmet Bushman Final ok
|
ELE19-00511
| Electrical Rough-In | 2/21/2019 | 2/21/2019 | 2/21/2019 1:10:05 PM | P | PASS |
|
|
Tobias is the site contact. We need a wall rough. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker walls only ok to cover
|
ELE19-00509
| Final | 2/20/2019 | 2/21/2019 | 2/21/2019 12:30:11 PM | P | PASS |
|
|
install ready for inspection; approved plans onsite; all work done according to approved plans with no deviations required; customer is home most often, so give her a call at 208.794.3918 and she''ll open the garage door for you. if you have any questions about the work, call Jed at 801.875.3714 Phone #: ###-#### Inspection requested via web by Ryan King Final ok
|
ELE18-03808
| Final | 2/20/2019 | 2/21/2019 | 2/21/2019 11:51:05 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk exposed romex between upper cab receps needs covered/protected
|
ELE18-03881
| Electrical Rough-In | 2/21/2019 | 2/21/2019 | 2/21/2019 11:18:19 AM | P | PASS |
|
|
Late afternoon // Mark Phone #: ###-#### Remaining ceiling and front entry columns only ok to cover
|
ELE19-00613
| Electrical Rough-In | 2/20/2019 | 2/21/2019 | 2/21/2019 11:17:39 AM | A | PASS |
|
|
Contact: Brian Prussia ###-#### Phone #: ###-#### Inspection requested via web by BRS Permitting Listing and interior panel ok
|
ELE19-00593
| Rough-In Permanent Service | 2/20/2019 | 2/21/2019 | 2/21/2019 10:48:43 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn rough in ok p/s u/g n ok
|
ELE18-03913
| Electrical Rough-In | 2/21/2019 | 2/21/2019 | 2/21/2019 10:12:51 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Eric Landberg Generator wiring and ATS wiring ok
|
ELE18-03914
| Electrical Rough-In | 2/20/2019 | 2/21/2019 | 2/21/2019 10:11:42 AM | A | PASS |
|
|
Need an underground inspection for the building 24D emergency generator before we cover it. Phone #: ###-#### Inspection requested via web by Eric Landberg Underground to building only ok to cover
|
ELE19-00642
| Rough-In Permanent Service | 2/20/2019 | 2/21/2019 | 2/21/2019 9:09:37 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Heideman rough in ok p/s u/g n ok
|
ELE19-00525
| Temporary Service | 2/20/2019 | 2/21/2019 | 2/21/2019 9:05:13 AM | A | PASS |
|
|
Temp pole Phone #: ###-#### Inspection requested via web by Kevin Heideman t/s u/g n ok
|