Inspections for the day of: Wednesday, March 8, 2017.
Number of inspections: 7
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-00559 Electrical Rough-In3/8/20173/8/20173/8/2017 12:56:20 PMPPASS
Tim Phone #: ###-#### North Offices only Rough in ok
ELE17-00533 Final3/7/20173/8/20173/8/2017 12:53:59 PMAPASS
Final for meter pack Final ok
ELE16-02440 Final3/8/20173/8/20173/8/2017 12:53:35 PMPPASS
Tim Phone #: ###-#### Service only Final ok
ELE16-02342 Final3/7/20173/8/20173/8/2017 12:18:28 PMAPASS
Final for service Final ok
ESC15-01579 Tracking Control3/8/20173/8/20173/8/2017 11:52:30 AMAFAIL
No track out control observed
ELE16-03763 Electrical Rough-In3/7/20173/8/20173/8/2017 9:22:39 AMAPASS
Paver grid bonding around tub Phone #: ###-#### Inspection requested via web by Lars Johnson Paver grid bond ok, Will verify pavers between fence and tub and will verify Gas fire pit.
ELE16-02746 Electrical Rough-In3/7/20173/8/20173/8/2017 12:00:00 AMPFAIL
building #2; Phone #: ###-#### 240.24 D overcurrent protection shall not be located in closets. 210.52 B 2 Small appliance circuits shall have no other outlets. Misc Recep additions and NM cable strapping. Next Inspection request needs room numbers listed.