Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-02520 ELE-Aging Inspection4/1/20194/1/20194/2/2019 11:16:01 AM DONE
Spoke to David. He will call for final soon.
ELE16-03148 ELE-Aging Inspection4/1/20194/1/20194/2/2019 11:10:18 AM FAIL
Spoke with Lars. He was unfamiliar with the job. No corrections have been made at this time.
ELE18-01391 Final4/1/20194/1/20194/1/2019 2:49:16 PMPPART
Contact Scott for Level 1, LL1 and LL3 walk down final inspection for all excluding electrical rooms on each floor and the parking on level 1. Phone #: ###-#### Inspection requested via web by Tom Betty 210.63 Heating and air conditioning equipment outlet. Recep shall be within 25ft of mini split condensor unit. Child care area needs recep trimmed. Kitchen needs GFCI protection and appliances installed. Faculty room checked and waiting for cubicals. All other areas checked and ready for final
ELE19-00166 Electrical Rough-In4/1/20194/1/20194/1/2019 1:16:23 PMPPASS
Kitchen remodel Phone #: ###-#### Inspection requested via web by Shaun Kirkman Kitchen only ok to cover
ELE19-00553 Final4/1/20194/1/20194/1/2019 1:16:00 PMPPASS
Please give me half an hour notice prior to inscpection to inure access. Thank you Shaun ###-#### Phone #: ###-#### Inspection requested via web by Shaun Kirkman Final ok
ELE19-00553 Electrical Rough-In4/1/20194/1/20194/1/2019 1:15:42 PMPPASS
Please give me half an hour notice prior to inscpection to inure access. Thank you Shaun ###-#### Phone #: ###-#### Inspection requested via web by Shaun Kirkman Rough in master bath ok to cover
ELE18-01857 Final3/28/20194/1/20194/1/2019 9:54:47 AMACANC
Partial final
3rd and 2nd floor. Phone #: ###-#### Inspection requested via web by cris flores
ELE18-01857 Electrical Rough-In4/1/20194/1/20194/1/2019 9:54:26 AMPPASS
Partial final
3rd and 2nd floor. Phone #: ###-#### Inspection requested via web by cris flores 3rd floor hot check ok. Ready for final
ELE19-00460 Electrical Rough-In3/31/20194/1/20194/1/2019 9:52:35 AMAPASS
inspect driveway mats for concrete install so we can pour Phone #: ###-#### Inspection requested via web by kevin blackmon Driveway heat only ok to cover
ELE18-03881 Electrical Rough-In3/29/20194/1/20194/1/2019 9:51:38 AMAPASS
celing- Mark Phone #: ###-#### Drop ceilings only. Salon and restrooms not ready at this time. MC ok to be supported by grid wire as per D. Degrang.
ELE19-00623 Electrical Rough-In3/31/20194/1/20194/1/2019 8:46:15 AMAPASS
Phone #: ###-#### Inspection requested via web by Kyle Dillon Kitchen and up bath ok to cover
ELE19-00623 Permanent Service4/1/20194/1/20194/1/2019 8:43:57 AMPPASS
Phone #: ###-#### Inspection requested via web by Kyle Dillon p/s o/h rec ok
ELE19-01106 Rough-In Permanent Service3/31/20194/1/20194/1/2019 8:21:35 AMAPASS
Phone #: ###-#### Inspection requested via web by Kevin Heideman rough in ok p/s u/g n ok
ELE19-00623 Electrical Rough-In3/27/20194/1/20193/31/2019 5:26:51 PMPCANC
Kyle Phone #: ###-#### Inspection cancelled from web by: Kyle Dillon