ELE19-01771
| Electrical Rough-In | 5/23/2019 | 5/23/2019 | 5/23/2019 3:16:36 PM | P | PASS |
|
|
Looking for a cover inspection on the interior six inch wall near the new plumbing areas in the back room space! Thx, Steve BPL Phone #: ###-#### Inspection requested via web by Steven Meredith washer/ dryer wall and H2o heater wall ok to cover
|
ELE19-01906
| Final | 5/23/2019 | 5/23/2019 | 5/23/2019 2:58:49 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wilson final ok
|
ELE19-01909
| Final | 5/23/2019 | 5/23/2019 | 5/23/2019 2:55:10 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wilson final ok
|
ELE19-01905
| Final | 5/23/2019 | 5/23/2019 | 5/23/2019 2:39:06 PM | P | NH |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wilson No access re-call
|
ELE19-01200
| Final | 5/23/2019 | 5/23/2019 | 5/23/2019 2:31:47 PM | P | PASS |
|
|
Matt Kirkland on site, ###-#### Phone #: ###-#### Inspection requested via web by Bryan Atkins No signature sheet onsite final ok
|
ELE19-01897
| Conference | 5/23/2019 | 5/23/2019 | 5/23/2019 2:05:28 PM | P | PASS |
|
|
Stan Phone #: ###-#### Covered alot of info. Tamper receps, GFCI protection, Counter recep spacing, Circuit requirments. Made owner aware of dedicated sm appl circuits and dish/disp. micro and hood circuits. Owner has handout as well.
|
ELE19-01907
| Final | 5/23/2019 | 5/23/2019 | 5/23/2019 1:15:12 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wilson Final ok
|
ELE19-01907
| Electrical Rough-In | 5/23/2019 | 5/23/2019 | 5/23/2019 1:15:03 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wilson rough in ok
|
ELE19-01908
| Final | 5/23/2019 | 5/23/2019 | 5/23/2019 1:00:21 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wilson Final ok
|
ELE19-00687
| Final | 5/23/2019 | 5/23/2019 | 5/23/2019 12:54:54 PM | P | FAIL |
|
|
Keith-call for access code Phone #: ###-#### 210.8 Kitchen counter shall be gfci protected. 210.52. Kitchen counter 12in or greater shall have recep. No more than 24in from wall break to recep. (RT of slider and RT of range)
|
ELE19-01878
| Rough-In Permanent Service | 5/21/2019 | 5/23/2019 | 5/23/2019 12:18:25 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Heideman rough in ok p/s u/g n ok
|
MIS19-00134
| ELE-Conference | 5/23/2019 | 5/23/2019 | 5/23/2019 11:41:38 AM | P | DONE |
|
|
work being done is structural, ele & fire sprinkler without permits No High volt wiring done yet. Low voltage only.
|
ELE18-04297
| Final | 5/22/2019 | 5/23/2019 | 5/23/2019 11:32:46 AM | A | FAIL |
|
|
front door should be open, or there is a key under a block in the entery Phone #: ###-#### Inspection requested via web by Neal Rumsey 210.52B1 Kitchen counter shall be served by 2 20A circuits. 406.9A Outdoor receps shall be type WR(Recp by a/c same recep is also dead.)
|
ELE19-01733
| Final | 5/23/2019 | 5/23/2019 | 5/23/2019 10:55:03 AM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Rob Maes
|
ELE18-03590
| Final | 5/22/2019 | 5/23/2019 | 5/23/2019 10:54:34 AM | A | PASS |
|
|
Final Inspection at Tray Wash Area Contact Pierre Elskamp Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek final ok
|
ELE19-01733
| Final | 5/21/2019 | 5/23/2019 | 5/23/2019 10:23:24 AM | A | PASS |
|
|
Call onsite electrician, George Stanton, with any questions. Phone #: ###-#### Inspection requested via web by Rob Maes Final ok
|
ELE19-00686
| Final | 5/23/2019 | 5/23/2019 | 5/23/2019 10:22:56 AM | A | PASS |
|
|
Garage code 9378 or 5674 Phone #: ###-#### Inspection requested via web by Rowdy Monroe Final ok
|
ELE19-01355
| Conference | 5/22/2019 | 5/23/2019 | 5/23/2019 9:25:36 AM | A | PASS |
|
|
just want a quick chat about this premanufactured structure. thanks. Phone #: ###-#### Inspection requested via web by Mark Gibson Spoke with contractor. He will fix violations in cabinet. Replace THHN in cable tray with TC rated cable and correct violations in lighting and recep circuits.
|
ELE19-01023
| Permanent Service | 5/23/2019 | 5/23/2019 | 5/23/2019 9:23:03 AM | A | CANC |
|
|
This is a service change and we may be ready before noon. Please call 45 min prior to arrival. John ###-#### Phone #: ###-#### Inspection requested via web by John Edwards
|
ELE19-00882
| Final | 5/22/2019 | 5/23/2019 | 5/23/2019 9:21:57 AM | A | PASS |
|
|
The lock box is 3380, if you have any questions, please call Jason at ###-####. Thank You!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Final ok
|
ELE19-01841
| Final | 5/21/2019 | 5/23/2019 | 5/22/2019 7:21:52 AM | A | CANC |
|
|
Call foreman, Brad Hallman, with any questions. Phone #: ###-#### >> Inspection requested via web by Rob Maes Inspection cancelled from web by: Rob Maes
|