ELE16-02065
| Final | 6/29/2016 | 6/29/2016 | 6/29/2016 2:56:18 PM | P | PASS |
|
|
Call Shawna for access ###-#### Phone #: ###-#### Inspection requested via web by jamie berg Final ok
|
ELE16-02010
| Final | 6/29/2016 | 6/29/2016 | 6/29/2016 2:02:34 PM | P | PASS |
|
|
We are requesting a final inspection for this afternoon. Please call Dave @ ###-#### so he can get you in the building. Thank you, Phone #: ###-#### Inspection requested via web by Clint Tate Final ok
|
ELE16-02010
| Electrical Rough-In | 6/29/2016 | 6/29/2016 | 6/29/2016 1:55:59 PM | P | PASS |
|
|
We are requesting a final inspection for this afternoon. Please call Dave @ ###-#### so he can get you in the building. Thank you, Phone #: ###-#### Inspection requested via web by Clint Tate Rpough in ok
|
ELE16-01416
| Electrical Rough-In | 6/29/2016 | 6/29/2016 | 6/29/2016 1:25:41 PM | P | PASS |
|
|
Pool Bonding Phone #: ###-#### Inspection requested via web by Emmet Bushman Pool bonding only, Rough in ok to cover
|
ELE16-02067
| Electrical Rough-In | 6/29/2016 | 6/29/2016 | 6/29/2016 12:35:24 PM | P | PASS |
|
|
Uffer Inspection Phone #: ###-#### Inspection requested via web by Tye Thomas Uffer only. Ok to cover
|
ELE16-01138
| Final | 6/29/2016 | 6/29/2016 | 6/29/2016 12:28:28 PM | P | FAIL |
|
|
Garage code JAYO enter Phone #: ###-#### Inspection requested via web by Zane Robertson 334.15 b. NM Cable shall be protected from physical damage. (Front of kitchen island is not finished) 314.20. Boxes set back more than a 1/4" shall have listed extension rings. (Back wall, Down master bed)
|
ELE16-00805
| Final | 6/29/2016 | 6/29/2016 | 6/29/2016 11:54:07 AM | P | CANC |
|
|
Please call Jared with any questions ###-####. Thank You!! Phone #: ###-#### Inspection requested via web by Clay Morgan Needed rough in
|
ELE16-00805
| Electrical Rough-In | 6/29/2016 | 6/29/2016 | 6/29/2016 11:53:45 AM | P | PASS |
|
|
Please call Jared with any questions ###-####. Thank You!! Phone #: ###-#### Inspection requested via web by Clay Morgan Rough in of remodel 1st and 2nd floor only.. ok to cover
|
ELE16-01857
| Permanent Service | 6/28/2016 | 6/29/2016 | 6/29/2016 10:32:42 AM | A | PASS |
|
|
Service Inspection for new portable. Contact is Bill Stokes. Phone #: ###-#### Inspection requested via web by Richard Montgomery p/s u/g n ok
|
ELE16-02053
| Temporary Service | 6/29/2016 | 6/29/2016 | 6/29/2016 10:07:12 AM | A | PASS |
|
|
Call when heading that way please. Chris is contact. Thank you!! Phone #: ###-#### Inspection requested via web by Chris Chesnut t/s o/h n ok
|
ELE16-01274
| Permanent Service | 6/28/2016 | 6/29/2016 | 6/29/2016 10:06:22 AM | A | PASS |
|
|
Permanent power building U Phone #: ###-#### Inspection requested via web by Bob Stephens p/s u/g n ok
|
ELE16-01589
| Permanent Service | 6/28/2016 | 6/29/2016 | 6/29/2016 10:06:17 AM | A | PASS |
|
|
Permanent power building T Phone #: ###-#### Inspection requested via web by Bob Stephens p/s u/g n ok
|
ELE16-00756
| Permanent Service | 6/28/2016 | 6/29/2016 | 6/29/2016 10:06:10 AM | A | PASS |
|
|
Permanent power building M Phone #: ###-#### Inspection requested via web by Bob Stephens p/s u/g n ok
|
GCE15-00148
| GCE-Final | 6/28/2016 | 6/29/2016 | 6/29/2016 9:00:39 AM | A | FAIL |
|
|
Tom ###-#### 210.8 A 1 Bathroom recepticles shall be GFCI Protected.(Down hall bath) 210.8 A 3. Outdoor recepticles shall be GFCI Protected. Up patio and front entry weather proof. Xmas GFCI will not trip
|