Inspections for the day of: Tuesday, January 19, 2016.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRex Boyles
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-00157 Electrical Rough-In1/18/20161/19/20161/19/2016 3:16:15 PMPPASS
Phone #: ###-#### Inspection requested via web by Dustin Kuester r/i walls and ceilings ok
ELE16-00165 Electrical Rough-In1/19/20161/19/20161/19/2016 2:28:17 PMPPASS
Phone #: ###-#### Inspection requested via web by danny perrine r/i ok bathroom walls and ceiling, serving counter
ELE15-02428 Electrical Rough-In1/19/20161/19/20161/19/2016 2:04:47 PMPPASS
Alan Phone #: ###-#### r/i ok will finish making up ground wires and landing grounds and nuetrals in sub panel , then call for final after trim is complete.
ELE15-01705 Final1/18/20161/19/20161/19/2016 1:38:42 PMPPASS
Owner will be home after noon. Phone #: ###-#### Inspection requested via web by Warren Fry final ok
ELE15-02949 Electrical Rough-In1/17/20161/19/20161/19/2016 12:47:01 PMAPASS
Phone #: ###-#### Inspection requested via web by Craig Korell r/i ok will call in r/i inspection for mini split wiring when ready. UNIT 26 lower level
ELE15-02960 Electrical Rough-In1/18/20161/19/20161/19/2016 12:12:58 PMAPASS
Ceiling Inspection for level 9 at One Capital Center Contact Jon Novak Phone #: ###-#### Inspection requested via web by Cathy Duchek r/i 9th flr ceilings ok
ELE16-00085 Final1/18/20161/19/20161/19/2016 11:37:58 AMAPASS
Ordered by Trent Hammon
Electrician who preformed work, Bryant ###-#### Phone #: ###-#### Inspection requested via web by Clint Tate final ok
ELE16-00171 Permanent Service1/19/20161/19/20161/19/2016 10:58:06 AMPCANC
Replacing the service, please call Matt ###-#### to make sure they are ready for inspection. Thank You! Phone #: ###-#### >> Inspection requested via web by Clay Morgan Inspection cancelled from web by: Clay Morgan
ELE16-00152 Conference1/18/20161/19/20161/19/2016 10:49:55 AMADONE
Phone #: ###-#### Inspection requested via web by Chris Chesnut discuss mc cable use and ber receptacles requiring GFCI protection , exit and egress lighting and bathroom GFCI protected receptacles.
ELE16-00118 Permanent Service1/15/20161/19/20161/19/2016 9:56:15 AMAPASS
Bob Phone #: ###-#### p/s o/h rec ok
ELE15-03539 Electrical Rough-In1/18/20161/19/20161/19/2016 9:31:05 AMAPASS
Ceiling inspection please Phone #: ###-#### Inspection requested via web by Celinda Winters r/i ceilings ok in molecular lab
ELE15-03926 Final1/18/20161/19/20161/19/2016 9:05:47 AMAFAIL
Phone #: ###-#### Inspection requested via web by Warren Fry 210.8 (B)(2)-all 120 volt 15 and 20 amp receptacles in other than dwellings shall have GFCI protection. No power to stock room receptacles also needing GFCI protection. No ground to hallway receptacle. UL listing for tortilla warmer
ELE15-03767 Electrical Rough-In1/19/20161/19/20161/19/2016 8:24:50 AMAPASS
Phone #: ###-#### Inspection requested via web by Mark M r/i ceilings ok in Misti pharmacy areas
ELE13-01783 ELE-Aging Inspection1/19/20161/19/20161/19/2016 7:41:06 AM DONE
too busy