ELE15-03461
| Final | 3/8/2016 | 3/8/2016 | 3/8/2016 3:59:22 PM | P | FAIL |
|
|
Gfi Installed In Laundry And Conduit Strapped As Per Rex! Thanks Dave Phone #: ###-#### Inspection requested via web by jason shifflett washer receptacle within 4 foot of sink shall have GFCI protection.
|
ELE16-00353
| Final | 3/8/2016 | 3/8/2016 | 3/8/2016 3:39:59 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by kendall bender 210.8(B)(1)-all 120 volt receptacles in "other than dwellings" shall have GFCI protection. 210.8-GFCI receptacle for drinking fountain not readily accessable. 110.16- All loadcenters, panels, etc. shall have arc flash hazard warning labels. Need 1/2 KO seal in gutter at back wall.
|
ELE16-00732
| Final | 3/8/2016 | 3/8/2016 | 3/8/2016 2:39:09 PM | P | PASS |
|
|
Call for access after 2:30PM Joel Miller ###-#### Phone #: ###-#### Inspection requested via web by jamie berg final ok
|
ELE16-00732
| Electrical Rough-In | 3/8/2016 | 3/8/2016 | 3/8/2016 2:38:04 PM | P | PASS |
|
|
Call for access after 2:30PM Joel Miller ###-#### Phone #: ###-#### Inspection requested via web by jamie berg r/i power to a/c and furnace
|
ELE16-00362
| Final | 3/8/2016 | 3/8/2016 | 3/8/2016 2:08:11 PM | P | PASS |
|
|
would like call 30min ahead; Rocky Phone #: ###-#### final ok house and garage
|
ELE16-00613
| Final | 3/3/2016 | 3/8/2016 | 3/8/2016 1:21:55 PM | P | CANC |
|
|
Service change from 200 amp to 400 amp. Please call Butch with questions, if any. Idaho power will be there @ 9:00 am job completed late in afternoon. Phone #: ###-#### Inspection requested via web by Daniel Schaffeld needed p/s
|
ELE16-00613
| Permanent Service | 3/8/2016 | 3/8/2016 | 3/8/2016 1:21:12 PM | P | PASS |
|
|
Service change from 200 amp to 400 amp. Please call Butch with questions, if any. Idaho power will be there @ 9:00 am job completed late in afternoon. Phone #: ###-#### Inspection requested via web by Daniel Schaffeld p/s u/g n ok crew there now at 1;20 pm
|
ELE16-00726
| Temporary Service | 3/7/2016 | 3/8/2016 | 3/8/2016 11:49:32 AM | A | PASS |
|
|
Thank You!! Phone #: ###-#### Inspection requested via web by Clay Morgan t/s o/h n ok
|
ELE16-00558
| Final | 3/7/2016 | 3/8/2016 | 3/8/2016 11:29:08 AM | A | PASS |
|
|
Call for access will give you lockbox combination Phone #: ###-#### Inspection requested via web by robert feller final ok
|
ELE16-00718
| Electrical Rough-In | 3/7/2016 | 3/8/2016 | 3/8/2016 11:06:58 AM | A | PASS |
|
|
Timothy// please call before Phone #: ###-#### r/i ok including u.ground, loadcenter and building wiring
|
ELE16-00704
| Final | 3/7/2016 | 3/8/2016 | 3/8/2016 10:18:52 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Randy Fletcher needed r/i for now
|
ELE16-00704
| Electrical Rough-In | 3/8/2016 | 3/8/2016 | 3/8/2016 10:18:18 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Fletcher new 20 amp circuit to D/W and Disp. and fix exposed SER cable subject to damage in crawl. Chris will install 80 amp breaker on #2 alum ser
|
ELE15-03461
| Final | 3/7/2016 | 3/8/2016 | 3/8/2016 9:51:11 AM | A | FAIL |
|
|
Its Ready lockbox code is 1993 call with any questions or Concerns ###-#### Inspection requested via web by jason shifflett 210.8(B)(7)- receptacles within 6 foot of sinks require GFCI protection. Strap 1inch under panel, Receptacles in laundry room hanging out of wall. Tile guy pulling devices for tile work. Call in when tile is done. Rear building not being completed as per Dave.
|
ELE16-00548
| Electrical Rough-In | 3/7/2016 | 3/8/2016 | 3/8/2016 8:56:26 AM | A | PASS |
|
|
Should have access through the garage. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan r/i shop ok
|
ELE16-00595
| Temporary Service | 3/7/2016 | 3/8/2016 | 3/8/2016 8:17:23 AM | A | PASS |
|
|
Contact: Todd ###-#### Phone #: ###-#### Inspection requested via web by Tracy Robertson t/s u/g n ok
|
ELE13-00227
| ELE-Aging Inspection | 3/8/2016 | 3/8/2016 | 3/8/2016 7:44:42 AM | | DONE |
|
|
too busy
|
ELE13-00213
| ELE-Aging Inspection | 3/8/2016 | 3/8/2016 | 3/8/2016 7:44:21 AM | | DONE |
|
|
too busy
|
ELE13-00255
| ELE-Aging Inspection | 3/8/2016 | 3/8/2016 | 3/8/2016 7:44:00 AM | | DONE |
|
|
too busy
|
ELE13-00185
| ELE-Aging Inspection | 3/8/2016 | 3/8/2016 | 3/8/2016 7:43:33 AM | | DONE |
|
|
too busy
|