Inspections for the day of: Thursday, August 28, 2014.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRex Boyles
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-02392 ELE-Aging Inspection8/28/20148/28/20148/28/2014 3:28:56 PM DONE
too busy
ELE11-00368 ELE-Aging Inspection8/28/20148/28/20148/28/2014 3:24:44 PM DONE
too busy
ELE14-01264 Final8/28/20148/28/20148/28/2014 3:15:32 PMPPASS
Call first please. Phone #: ###-#### Inspection requested via web by Greg Idsinga final ok
ELE14-01497 Final8/27/20148/28/20148/28/2014 2:57:51 PMPPASS
Someone should be there. Otherwise call for lock box combo. Thanks. Phone #: ###-#### Inspection requested via web by Clay Morgan final ok
ELE14-02209 Rough-In Permanent Service8/28/20148/28/20148/28/2014 2:18:32 PMPPASS
Phone #: ###-#### Inspection requested via web by daniel bibikov r/i ok p/s u/g n ok 4 units 101,102,201 and 202 and house panel
ELE14-02209 Rough-In Permanent Service8/28/20148/28/20148/28/2014 1:33:53 PMPCANC
Phone #: ###-#### Inspection requested via web by daniel bibikov called in twice cancel this one
ELE14-02265 Electrical Rough-In8/27/20148/28/20148/28/2014 12:49:49 PMPPASS
Matt. Can you call half hour prior to heading towards site. Phone #: ###-#### Inspection requested via web by Sean DeLacy r/i loadcenters flipped 180 degrees now in bdrms. and not in closets. Remove bonding screws to separate nuetral before final inspection!
ELE14-02265 Permanent Service8/28/20148/28/20148/28/2014 12:43:07 PMPPASS
Matt. Can you call half hour prior to heading towards site. Phone #: ###-#### Inspection requested via web by Sean DeLacy p/s o/h rec ok Already done!! no need for service tech
ELE14-01896 Electrical Rough-In8/27/20148/28/20148/28/2014 12:41:23 PMPPASS
Matt. Can you call half hour prior to heading towards site. Phone #: ###-#### Inspection requested via web by Sean DeLacy r/i ok for water heater circuit and washer dryer circuits and mini split power and controls for units A,B,C and D also remove bonding screws in loadcenters before final insp.
ELE14-01667 Electrical Rough-In8/27/20148/28/20148/28/2014 12:35:17 PMPPASS
Matt. Can you call half hour prior to heading towards site. Phone #: ###-#### Inspection requested via web by Sean DeLacy r/i ok for washer dryer and water heater and mini split power and control wiring units A and B. r/i ok for water heater and mini split wirng and controls for unit C. bonding screws in all four panels need to be removed before final insp.
ELE14-02104 Final8/27/20148/28/20148/28/2014 11:14:27 AMACANC
INSPECTION FOR TEMP OCCUPANCY Phone #: ###-#### Inspection requested via web by JENNY EMEL needed r/i
ELE14-02375 Temporary Service8/27/20148/28/20148/28/2014 11:14:26 AMAFAIL
Overhead temp Phone #: ###-#### Inspection requested via web by TOM BICANDI ground rod acorn very loose.
ELE14-02104 Electrical Rough-In8/28/20148/28/20148/28/2014 10:59:27 AMPPASS
INSPECTION FOR TEMP OCCUPANCY Phone #: ###-#### Inspection requested via web by JENNY EMEL r/i office furniture
ELE14-01029 Final8/28/20148/28/20148/28/2014 10:13:59 AMPPASS
Jay Phone #: ###-#### final ok
ELE14-00950 Final8/26/20148/28/20148/28/2014 9:34:47 AMAFAIL
Please call Kevin deBelloy to meet you ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan GFCI for tub still not readily accessable
ELE14-02250 Final8/27/20148/28/20148/28/2014 9:09:45 AMAPASS
Matthew, the tenant will be there. If you have any questions, please call ###-####, thank you. Phone #: ###-#### Inspection requested via web by Clay Morgan final ok
ELE14-02364 Electrical Rough-In8/26/20148/28/20148/28/2014 8:53:27 AMAPASS
Hoff building - 12th floor Phone #: ###-#### Inspection requested via web by Lars Johnson r/i ok walls and ceilings