Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-00141 Final1/10/20201/13/20201/13/2020 3:50:33 PMPPASS
Please call John to ensure install is complete. ###-#### Thank you! Phone #: ###-#### Inspection requested via web by Rick Borg
MEC20-00165 Final1/13/20201/13/20201/13/2020 3:21:44 PMPNH
Phone #: ###-#### Inspection requested via web by max sanders- no one answered doorbell or knock- reschedule when someones available for inspection
MEC19-02079 Final1/9/20201/13/20201/13/2020 2:53:45 PMPPASS
Please call to ensure ladder is on site for access to the furnace. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- electric furnace in attic coil a/c co locking caps ok
MEC20-00151 Final1/13/20201/13/20201/13/2020 2:26:10 PMPPASS
Please call Jeff Larson upon arrival so he can let you in to locked building. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- air handler coil a/c locking caps ok
MEC19-01679 Rough-in1/10/20201/13/20201/13/2020 1:51:34 PMPPART
Area C for cover Phone #: ###-#### Inspection requested via web by Amanda Farnsworth- area D rooms 106, 109, and 100 hallway ok for ceiling tiles
area C 106, 107, 108, 109, 110, 111, 112, 113 and 114 ok for ceiling tiles
area C 104 and 105 media center ok for ceiling tiles
2nd layer firewrap on grease duct ok- all grease duct done
MEC19-02561 Final1/10/20201/13/20201/13/2020 11:14:39 AMAPART
Roger Graves the site superintendent will be the onsite contact his phone number is ###-####. Phone #: ###-#### Inspection requested via web by Doug Madsen
1- oven needs set under hood to check clearances
2- air balance on EF 2 for hood onsite
3- R/A in storage room needs R6 flex duct installed
4- need approved fittingand ducting to class 2 hood and sealed- has make shift ducting to hood need to replace

Roof is good- call in final when all equipment and corrections made and air balance report onsite
MEC19-04546 Final1/10/20201/13/20201/13/2020 10:27:57 AMAPASS
GARI ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace final ok
MEC20-00052 Rough-in1/13/20201/13/20201/13/2020 10:01:15 AMAPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- R/I ok
MEC19-05263 Final1/10/20201/13/20201/13/2020 9:32:48 AMAPASS
call acess- Tim Phone #: ###-####- final ok- equipment set in place
MEC19-03068 Final1/10/20201/13/20201/13/2020 9:17:15 AMANH
Inspection requested via web by Margie Rowe- no one home- no access- left notice
MEC19-05253 Rough-in1/9/20201/13/20201/13/2020 9:00:28 AMAPASS
call eric when on the way ###-#### Phone #: ###-#### Inspection requested via web by Lindsey Stegemann- fireplace R/I ok= call in final when ready
MEC20-00098 Rough-in1/10/20201/13/20201/13/2020 8:55:42 AMACANC
Close to 10am would be optimal, if possible with inspectors schedule. Please contact Shawn Marquez with any issues. ###-#### Phone #: ###-#### Inspection requested via web by Amanda Casper- all fire dampers need removed- will need to meet 1 hour rating on exhaust fan- Shawn will get with building inspector after dampers are remove to see how to meet 1 hour rating on fan- rerschedule when ready
MEC19-05215 Final1/9/20201/13/20201/13/2020 8:26:40 AMAPASS
We also need to do the witness pressure test. Tech will arrive at 8 to get it under pressure and Brian Scoles will meet technician there at 8:30. Gary Grabulis ###-####. Thank You Phone #: ###-#### Inspection requested via web by Shari Wetzler- furnace a/c coil co locking caps ok- no flue test needed unconditioned space-
MEC20-00154 Rough-in1/10/20201/13/20201/13/2020 8:08:11 AMANH
Phone #: ###-#### Inspection requested via web by Sheldon Lebow- no one home- no access