MEC19-03943
| Final | 1/21/2020 | 1/21/2020 | 1/21/2020 4:10:06 PM | P | PASS |
|
|
Call for access // Joe Phone #: ###-####- final ok
|
MEC20-00284
| Final | 1/21/2020 | 1/21/2020 | 1/21/2020 3:49:04 PM | P | PASS |
|
|
INSTALLER DAKOTA ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok
|
MEC20-00182
| Rough-in | 1/20/2020 | 1/21/2020 | 1/21/2020 3:34:20 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- supply main in attic needs to be 18" round not 16" round as ran per man j 2- need to secure w/h b vent in chase 2nd floor
left do not cover sticker
|
MEC20-00182
| Pressure Test | 1/17/2020 | 1/21/2020 | 1/21/2020 3:32:42 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter location- 5lb flue pass
|
MEC20-00221
| Rough-in | 1/21/2020 | 1/21/2020 | 1/21/2020 3:15:08 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley 1- need to seal supply boot 1st floor at slider 2- need to fix all rips and tears in arma flex 1st and 2nd floor walls bare copper can be showing 3- need to fix 6" outside air pinched off at truss in attic above stairs 4- supply duct to master bath pinched off by hanger above door 5- need ladder provided by contractor to access furn/coil in attic 6- supply duct smashed by supply main trunk above hallway to bedroom 2 at truss
left notice front window
|
MEC20-00222
| Rough-in | 1/21/2020 | 1/21/2020 | 1/21/2020 3:11:21 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley 1- need ladder provided by contractor to access furn/coil in attic 2- need to fix all rips and tears in arma flex in attic 3- R/A duct needs to maintain nice radius from furnace R/A plenum to register can
left notice front window
|
MEC20-00221
| Pressure Test | 1/21/2020 | 1/21/2020 | 1/21/2020 3:09:16 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley- 20lb gas pass tagged meter location
|
MEC20-00222
| Pressure Test | 1/21/2020 | 1/21/2020 | 1/21/2020 3:08:55 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley- 20lb gas pass tagged meter location
|
MEC19-05673
| Final | 1/15/2020 | 1/21/2020 | 1/21/2020 2:41:18 PM | P | PASS |
|
|
Please inspect after 2 PM. He is elderly and it may take him some time to get to door. Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace only co ok
|
MEC20-00081
| Final | 1/16/2020 | 1/21/2020 | 1/21/2020 2:20:17 PM | P | PASS |
|
|
Please have inspector call Chuck the owner 15min prior to going out to home so that Chuck can meet inspector at the home. ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd- furnace a/c coil co locking caps ok
|
MEC20-00272
| Final | 1/20/2020 | 1/21/2020 | 1/21/2020 1:59:43 PM | P | PASS |
|
|
Please call Brett on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace a/c coil co locking caps ok
|
MEC20-00292
| Final | 1/21/2020 | 1/21/2020 | 1/21/2020 1:29:35 PM | P | FAIL |
|
|
PLEASE CALL OUR LEAD INSTALLER JOHNNY WHEN 30-45 MINS IN ROUTE SO HE CAN HAVE FLUE UNDER PRESSURE FOR WITNESSED WHEN YOU ARRIVE. LATER AFTERNOON IF AT ALL POSSIBLE- 3-5P Phone #: ###-#### Inspection requested via web by Rick Montgomery- furnace only co ok- flue not holding pressure- reschedule to meet when fixed and holding pressure
|
MEC19-04753
| Final | 1/20/2020 | 1/21/2020 | 1/21/2020 1:04:13 PM | P | FAIL |
|
|
Lock box code is 7777. Bj ###-#### Inspection requested via web by william kerwin 1- need duct blast and air balance report onsite 2- need approved man j onsite 3- seal exterior gas line penetrations
|
MEC19-04751
| Final | 1/20/2020 | 1/21/2020 | 1/21/2020 1:03:08 PM | P | FAIL |
|
|
Lock box 7777. Bj ###-#### Inspection requested via web by william kerwin 1- duct blast test and air balance reports onsite 2- fireplace installation instructions onsite none found 3- w/h flue needs 6" clearance to single wall pipe 4- approved man j onsite 5- seal exterior gas line penetrations
|
MEC19-04750
| Final | 1/20/2020 | 1/21/2020 | 1/21/2020 1:01:24 PM | P | FAIL |
|
|
Lockbox code 7777. Thanks BJ ###-#### Inspection requested via web by william kerwin- need fireplace installation instruction onsite none found- singke wall flue on water heater needs 6" clearance to sheetrock- need to seal exterior gas line penetrations
|
MEC19-05583
| Rough-in | 1/21/2020 | 1/21/2020 | 1/21/2020 12:29:12 PM | P | PASS |
|
|
repairs made and ready for re-inspection Call Tom with any questions ###-#### Phone #: ###-#### Inspection requested via web by Nick Drake- R/I ok- ok to cover
|
MEC20-00260
| Rough-in | 1/17/2020 | 1/21/2020 | 1/21/2020 11:25:51 AM | A | FAIL |
|
|
GARAGE CODE: 7445 Phone #: ###-#### Inspection requested via web by Kristy Watson 1- need to secure/support gas piping in attic 2- outside air needs tied into R/A plenum at furnace can not tie into R/A register can 3- missing 1 supply duct in bedroom 3 shows 2 only has 1
left notice front entry window
|
MEC20-00260
| Pressure Test | 1/21/2020 | 1/21/2020 | 1/21/2020 11:23:20 AM | A | PASS |
|
|
GARAGE CODE: 7445 Phone #: ###-#### Inspection requested via web by Kristy Watson- 20lb gas pass tagged meter location
|
MEC20-00256
| Rough-in | 1/20/2020 | 1/21/2020 | 1/21/2020 11:15:57 AM | A | PASS |
|
|
CHRISTINA ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
|
MEC20-00154
| Rough-in | 1/17/2020 | 1/21/2020 | 1/21/2020 10:40:44 AM | A | PART |
|
|
PLEASE CALL SHELDON 1 HR BEFORE SO HE CAN MEET YOU OUT THERE. ###-#### Phone #: ###-#### Inspection requested via web by Sheldon Lebow- fireplace R/I in living room only ok for cover- insulation shield verified in attic- need framing completed around b vent above roof and call in for inspection once framed and this will require a building permit and inspected prior to cover
|
MEC20-00268
| Final | 1/20/2020 | 1/21/2020 | 1/21/2020 10:23:05 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co locking caps ok
|
MEC20-00238
| Final | 1/16/2020 | 1/21/2020 | 1/21/2020 10:01:08 AM | A | FAIL |
|
|
Daniel Phone #: ###-####- need secondary drain wet switch installed- need locking caps on a/c service ports
|
MEC20-00274
| Final | 1/20/2020 | 1/21/2020 | 1/21/2020 9:31:10 AM | A | PASS |
|
|
call Wayne before coming Phone #: ###-#### Inspection requested via web by Kim Lithander- furnace a/c coil co locking caps ok
|
MEC19-04713
| Final | 1/17/2020 | 1/21/2020 | 1/21/2020 9:09:55 AM | A | FAIL |
|
|
ac 4141 Phone #: ###-#### Inspection requested via web by Gary Reeves 1- need to seal line set penetration at a/c 2- need to fix flue on water heater china cap, needs to maintain space bent over on legs
|
MEC19-00926
| Final | 1/16/2020 | 1/21/2020 | 1/21/2020 8:56:07 AM | A | FAIL |
|
|
Inspection requested via web by Aaron Alandt 1- need to use approved ul tape on range duct and remove duct tape thats installed 2- single wall b vent on water heater needs 6" clearance to electric cord and exhaust fan or run in b vent to achieve clearance
|
MEC19-05583
| Rough-in | 1/17/2020 | 1/21/2020 | 1/21/2020 8:35:43 AM | A | FAIL |
|
|
please call Tom Thacker ###-#### Phone #: ###-#### Inspection requested via web by Nick Drake- condensate lines on mini split need ran in 3/4" pvc and barb fitting near head to make tie in
|
MEC19-05540
| Final | 1/17/2020 | 1/21/2020 | 1/21/2020 8:19:13 AM | A | PASS |
|
|
Call when on way ###-#### Stan Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace only co ok
|
MEC19-01168
| DOC - Permit Expired | 1/21/2020 | 1/21/2020 | 1/21/2020 7:40:24 AM | A | PASS |
|
|
no calls-no activity- permit expired
|
MEC20-00182
| Rough-in | 1/17/2020 | 1/21/2020 | 1/20/2020 9:15:03 AM | A | CANC |
|
|
MEC AND FIREPL Phone #: ###-#### >> Inspection requested via web by Oleg Chervak Inspection cancelled from web by: Oleg Chervak
|