Inspections for the day of: Wednesday, January 29, 2020.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-05390 Final1/28/20201/29/20201/29/2020 3:57:20 PMPPASS
Please call Lonny in route to inspection ###-####--would like late as possible--he gets home at 330PM Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace only co ok
MEC19-03314 Final1/28/20201/29/20201/29/2020 3:37:26 PMPFAIL
Call for access Phone #: ###-#### Inspection requested via web by Bob Ferrin
1- w/h sinle wall flue doesnt have 6" clearance to sheetrock need to install 3" b vent adjustable 90 at ceiling to get clearances
2- need city approved man j onsite
3- need to seal line set penetration thru foundation vent outside at a/c location
MEC19-02908 Final1/24/20201/29/20201/29/2020 3:19:16 PMPFAIL
Please pre-call Alyssa if able prior to arrival. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- need weather stripping installed on furnace/ water heater closet doors floor ceiling and sides- need 3 co detectors- need locking caps on a/c service ports-
MEC20-00410 Final1/28/20201/29/20201/29/2020 2:50:04 PMPPASS
Please call tech Willie prior to arrival to ensure ready. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace a/c coil co locking caps ok
MEC20-00408 Final1/28/20201/29/20201/29/2020 2:26:58 PMPPASS
Please call tech Paul prior to arrival to ensure ready. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace only co ok
MEC20-00404 Final1/28/20201/29/20201/29/2020 1:57:05 PMPPASS
Please call tech Chris M prior to arrival to ensure ready. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace only co ok
MEC19-03846 Final1/29/20201/29/20201/29/2020 1:31:36 PMPPASS
final ok
MEC19-04175 Final1/28/20201/29/20201/29/2020 1:30:09 PMPPASS
please call Cody with any questions ###-#### Phone #: ###-#### Inspection requested via web by Nick Drake- final ok
MEC20-00406 Pressure Test1/28/20201/29/20201/29/2020 12:57:13 PMPNR
PLEASE CALL INSTALLER WARNE WHEN 30-45 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery- still installing qaiting on parts- went over onsite with installer about csst installation- need csst approved nail plates
MEC20-00405 Pressure Test1/28/20201/29/20201/29/2020 12:56:13 PMPNR
PLEASE CALL INSTALLER WARNE WHEN 30-45 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery- still installing waiting on parts- went over installation of csst onsite- need approved csst nail plates
MEC19-04429 Final1/28/20201/29/20201/29/2020 12:38:30 PMPFAIL
PLEASE CALL ON WAY, OR SHE MAY NOT OPEN DOOR MUHAMMED ###-#### Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING- need approved b vent reducer can not go from double wall to single wall then back to b vent- need locking caps on a/c service ports- talked with Jamie about this by phone
MEC19-05583 Rough-in1/28/20201/29/20201/29/2020 11:30:15 AMPPASS
please call tom with any questions ###-#### Phone #: ###-#### Inspection requested via web by Nick Drake- R/I on linset and condensate drains ok- ok to cover
MEC20-00386 Final1/29/20201/29/20201/29/2020 11:21:01 AMAPASS
final ok
MEC19-05450 Rough-in1/28/20201/29/20201/29/2020 11:17:02 AMAPASS
Cover inspection - call Josh Phone #: ###-#### Inspection requested via web by Brandon Sorensen- center stairwell east side rooms insulation, flex and registers all good excluding skills lab need to cap abandoned exhaust in ceiling, staff work area needs supply duct lengthened and register installed per reflected ceiling print and learning resorce room needs supplies and R/ A ducting capped above ceiling- call in final when ready- has air balance been completed??
MEC19-01679 Rough-in1/28/20201/29/20201/29/2020 10:01:42 AMPPASS
Kitchen Phone #: ###-#### Inspection requested via web by Amanda Farnsworth-R/I on rooms 112 kitchen, 112a 113 116 and 117 seal on duct ok- dishwasher exhaust seal ok- ok for ceiling grid
MEC20-00399 Final1/28/20201/29/20201/29/2020 9:35:54 AMAPASS
Please call homeowner Dick Todd prior to arrival Phone #: ###-#### Inspection requested via web by Jamee Shoecraft- pellet insert final ok
MIS20-00015 MEC-Conference1/17/20201/29/20201/29/2020 9:08:18 AMADONE
follow up inspection to see if permit has been issued- permit has been issued
MIS20-00015 DOC - Permit Finaled1/29/20201/29/20201/29/2020 9:08:03 AMPPASS
follow up inspection to see if permit has been issued- permit has been issued
MEC19-05630 Final1/28/20201/29/20201/29/2020 8:43:05 AMAPASS
Final for range hood, call Brett with any questions/concerns, ###-#### Phone #: ###-#### Inspection requested via web by Brett Shannon- final ok
MEC19-02999 Mec-Aging Inspection1/29/20201/29/20201/29/2020 8:12:58 AM CANC
talked with Kyle about scheduling this inspection- he will look into this
MEC18-05961 Mec-Aging Inspection1/29/20201/29/20201/29/2020 8:10:48 AM CANC
called and talked to Max about this- he will look into it
MEC19-04422 Final1/29/20201/29/20201/29/2020 7:49:11 AMAPASS
final ok
MEC18-04405 Mec-Aging Inspection1/29/20201/29/20201/29/2020 7:43:48 AM DONE
MEC18-04405 DOC - Permit Expired1/29/20201/29/20201/29/2020 7:43:37 AMAPASS
no calls for inspection- multiple aging- permit expired
MEC20-00410 Pressure Test1/28/20201/29/20201/28/2020 7:52:45 PMPCANC
Please call tech Willie prior to arrival to ensure ready. Phone #: ###-#### >> Inspection requested via web by Andrea Grigsby Inspection cancelled from web by: Andrea Grigsby