MEC18-06006
| Final | 1/4/2019 | 1/4/2019 | 1/4/2019 4:12:19 PM | P | PASS |
|
|
installer ###-####- flue test and final- 2 furnaces 2 a/c coil co ok- 5lb flue test pass both furnaces
|
MEC18-06133
| Final | 1/3/2019 | 1/4/2019 | 1/4/2019 3:51:03 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Marisa Hone- furnace a/c coil co ok
|
MEC18-05646
| Rough-in | 1/3/2019 | 1/4/2019 | 1/4/2019 3:25:08 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Otero- fireplace R/I ok
|
MEC19-00049
| Final | 1/4/2019 | 1/4/2019 | 1/4/2019 2:54:02 PM | P | NH |
|
|
Inspection requested via web by Margie Rowe- no one home- rang doorbell and knocked waited 5 mins no answer
|
MEC18-05489
| Final | 1/3/2019 | 1/4/2019 | 1/4/2019 2:23:13 PM | P | PASS |
|
|
Please call Yolanda prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
|
MEC18-05070
| Final | 1/4/2019 | 1/4/2019 | 1/4/2019 1:53:05 PM | P | PASS |
|
|
gas leak was fixed- furnace a/c coil co ok
|
MEC19-00031
| Final | 1/3/2019 | 1/4/2019 | 1/4/2019 1:43:14 PM | P | PASS |
|
|
INSTALLER JAROD ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok
|
MEC18-02348
| Final | 1/4/2019 | 1/4/2019 | 1/4/2019 1:21:54 PM | P | PASS |
|
|
no manual j needed for ducted mini split- mini split ok
|
MEC19-00016
| Final | 1/2/2019 | 1/4/2019 | 1/4/2019 11:16:29 AM | A | PASS |
|
|
Final inspection and flue test. We will call inspector 30 minutes prior to doing flue test. Phone #: ###-#### Inspection requested via web by Julie McMillan- furnace co ok- 5lb flue test pass
|
MEC18-05284
| Rough-in | 1/3/2019 | 1/4/2019 | 1/4/2019 10:30:36 AM | A | PASS |
|
|
Cover for Christian Faith Center, please call Mike ###-#### Phone #: ###-#### Inspection requested via web by Heather Gransbery- R/I ok- flex registers insulation ok- ok for ceiling tiles all areas- need to move electric heater in fire riser room to 8" off floor per fan installation instructions- need to look at regulators on roof at final and water heater fluing and verify RTU 1 2 3 & 4 have smoke detectors installed
|
MEC18-05928
| Final | 12/31/2018 | 1/4/2019 | 1/4/2019 9:27:29 AM | A | FAIL |
|
|
Please have inspector call the owner Paul ; Darla Cary when in route to home. ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd- b vent in attic needs insulation shield- all b vent needs 1" clearance to combustibles in furnace closet need to adjust- furnace a/c coil co ok
|
MEC18-05725
| Final | 1/3/2019 | 1/4/2019 | 1/4/2019 9:09:30 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Marisa Hone Inspection cancelled from web by: Marisa Hone
|
MEC18-04329
| Final | 1/2/2019 | 1/4/2019 | 1/4/2019 8:52:06 AM | A | FAIL |
|
|
Please call client prior to arrival at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Andrea Grigsby- bubble wrap insulation needs 3/4" air gap to maintain R-6 on supply and return ducts
|
MEC18-01532
| Mec-Aging Inspection | 1/4/2019 | 1/4/2019 | 1/4/2019 8:06:19 AM | | PASS |
|
|
plumbing permit was issued
|
MEC18-01532
| Final | 1/4/2019 | 1/4/2019 | 1/4/2019 8:05:57 AM | A | PASS |
|
|
furnace a/c coil co ok-
|
MEC18-00026
| Mec-Aging Inspection | 1/4/2019 | 1/4/2019 | 1/4/2019 8:05:21 AM | | FAIL |
|
|
contractor needs to schedule inspection with homeowner
|