MEC18-06146
| Final | 1/3/2019 | 1/7/2019 | 1/7/2019 2:53:13 PM | P | PASS |
|
|
Please give us a call when you are on your way so we can notify customer. Phone #: ###-#### Inspection requested via web by Dan McFate- furnace co ok
|
MEC18-06121
| Final | 1/7/2019 | 1/7/2019 | 1/7/2019 2:22:15 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- furnace a/c coil co ok
|
MEC19-00058
| Final | 1/7/2019 | 1/7/2019 | 1/7/2019 2:01:06 PM | P | PASS |
|
|
|
MEC19-00058
| Final | 1/4/2019 | 1/7/2019 | 1/7/2019 1:57:04 PM | P | PASS |
|
|
Final inspection for new gas piping installation. Phone number is for customer Marie Nunez. Phone #: ###-#### Inspection requested via web by Matt Jones- 20lb gas pass to range
|
MEC19-00072
| Rough-in | 1/7/2019 | 1/7/2019 | 1/7/2019 1:29:04 PM | P | PASS |
|
|
sealer inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok- seal on duct ok- ok to insulate and ceiling grid
|
MEC19-00066
| Final | 1/4/2019 | 1/7/2019 | 1/7/2019 12:51:14 PM | P | PASS |
|
|
Early PM Please call Blake prior to arrival ###-#### Inspection requested via web by Arielle Hendricks- furnace in crawl co ok
|
MEC19-00074
| Final | 1/7/2019 | 1/7/2019 | 1/7/2019 12:34:32 PM | P | CANC |
|
|
Robert Phone #: ###-####- need a unit number to know whuch mobile home it is for inspection
|
MEC18-06116
| Rough-in | 1/7/2019 | 1/7/2019 | 1/7/2019 12:03:52 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Terek Worley Inspection cancelled from web by: Terek Worley
|
MEC18-05698
| Rough-in | 1/7/2019 | 1/7/2019 | 1/7/2019 12:03:21 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Terek Worley Inspection cancelled from web by: Terek Worley
|
MEC18-04506
| Final | 1/4/2019 | 1/7/2019 | 1/7/2019 11:33:45 AM | A | PART |
|
|
Dave Godfrey is your site contact Phone #: ###-#### Inspection requested via web by RM Mechanical- conference room 119 final ok-
|
MEC18-04506
| Rough-in | 1/7/2019 | 1/7/2019 | 1/7/2019 11:33:13 AM | A | PASS |
|
|
Dave Godfrey is your site contact Phone #: ###-#### Inspection requested via web by RM Mechanical- R/I ok- seal ok-ok to insulate east side MRI room area
|
MEC19-00048
| Final | 1/4/2019 | 1/7/2019 | 1/7/2019 10:16:51 AM | A | CANC |
|
|
>> Inspection requested via web by Margie Rowe Inspection cancelled from web by: Margie Rowe
|
MEC18-02215
| Rough-in | 1/4/2019 | 1/7/2019 | 1/7/2019 10:02:38 AM | A | PART |
|
|
Mechanical 2nd Layer Fire wrap needed for Magnificent Garden if you have questions call Karl at ###-#### thank you Phone #: ###-#### Inspection requested via web by Karl Hestekin- missing a couple access doors still- need to add insulation straps on all 90s in throat to heal of 90s and a few places are farther than 12" apart- still need installation instruction on owner provided equipment to verify access doors need to have gasket/sealing meeting 1500 degrees
|
MEC18-05725
| Final | 1/4/2019 | 1/7/2019 | 1/7/2019 9:41:54 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Marisa Hone- need to witness flue test- pvc needs 1" clearance to b vent piping for water heater-
|
MEC18-04798
| Final | 1/3/2019 | 1/7/2019 | 1/7/2019 9:33:00 AM | A | FAIL |
|
|
Please call Rich 30 min prior if no call customer will not be there. If you call ahead he will make sure someone is there Phone #: ###-#### Inspection requested via web by Andrea Grigsby- bubble wrap insulation needs 3/4" gap to maintain R-6 value- b vent needs 1" clearance to combustibles at roof- flex b vent from furnace needs grade from furnace to b vent wye
|
MEC18-05971
| Final | 1/4/2019 | 1/7/2019 | 1/7/2019 8:58:25 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Marisa Hone- furnace co ok
|
MEC18-06153
| Final | 1/4/2019 | 1/7/2019 | 1/7/2019 8:37:09 AM | A | PASS |
|
|
Contact - Amy Thompson/Owner ###-#### Phone #: ###-#### Inspection requested via web by Dianne Maxwell- final ok
|
MEC18-00031
| Mec-Aging Inspection | 1/7/2019 | 1/7/2019 | 1/7/2019 8:09:13 AM | | FAIL |
|
|
dryer vent needs inspected and final needs called in
|
MEC19-00016
| Final | 1/4/2019 | 1/7/2019 | 1/4/2019 11:17:00 AM | A | CANC |
|
|
Final and flue test Phone #: ###-#### Inspection requested via web by Julie McMillan- completed on 1-4-19 in am
|