Inspections for the day of: Wednesday, January 9, 2019.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-00104 Final1/8/20191/9/20191/9/2019 3:55:15 PMPNH
Homeowner Larry ###-####
tech Cody ###-#### Phone #: ###-#### Inspection requested via web by Nick Drake- rang doorbell- no one home- no access
MEC19-00034 Final1/9/20191/9/20191/9/2019 3:27:06 PMPNR
Manufactured home A/C Phone #: ###-#### Inspection requested via web by jamie berg- need to finish welding line set at a/c- need arma flex installed and uv protection on lineset- need to get into mobile home if coil was replaced to check coil and drains
MEC19-00113 Final1/8/20191/9/20191/9/2019 2:59:51 PMPPASS
INSTALLER JAROD ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace co ok
MEC18-05844 Rough-in1/9/20191/9/20191/9/2019 2:26:06 PMPFAIL
Phone #: ###-#### Inspection requested via web by Bryan Palmer
1) need approved manual J onsite for inspection
2) csst gas piping needs secure/supported per manufactires installation instructions and gas piping into fireplace will need completed when set
3) exhaust fans need hooked up none set yet
4) crawl needs completed on R/I and boots mastic to floor
5) line set needs supported every 6 feet in wall and in attic and all rips and tears need fixed
6) furnace/water heater closet needs combustion air provided for them both
5)
MEC18-05844 Pressure Test1/9/20191/9/20191/9/2019 2:21:54 PMPPASS
Phone #: ###-#### Inspection requested via web by Bryan Palmer- 20lb gas pass
MEC19-00095 Final1/9/20191/9/20191/9/2019 2:03:31 PMPPASS
final ok
MEC19-00095 Rough-in1/9/20191/9/20191/9/2019 2:02:53 PMPPASS
please call in advance for access Phone #: ###-#### Inspection requested via web by Nicholas Paige- R/I ok
MEC19-00097 Final1/8/20191/9/20191/9/2019 1:05:21 PMPCANC
PLEASE CALL JOYCE Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
MEC18-05917 Conference1/9/20191/9/20191/9/2019 12:09:34 PMPDONE
We have some fire dampers installed and we want to make sure the inspector likes how it is done Phone #: ###-#### Inspection requested via web by Nicholas Paige- discussed fire dampers without sleeve from factory- installation instruction are a little different from approved prints- will get more info in next day or two
MEC18-04640 Final1/8/20191/9/20191/9/2019 11:29:22 AMAPASS
Inspection requested via web by Margie Rowe- electric furnace heat pump ok
MEC18-04280 Rough-in1/8/20191/9/20191/9/2019 10:41:20 AMAPART
We need a partial R/I for the 1st floor, please call Brad. Thank you! Phone #: ###-#### Inspection requested via web by Rhonda Marcum- seal on all ducting 1st floor ok- need to look at offsets and remainder of vav sealing- ok to insulate
MEC18-06101 Rough-in1/8/20191/9/20191/9/2019 8:50:15 AMAFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart- need ladder provided to access furnace in attic