Inspections for the day of: Thursday, October 17, 2019.
Number of inspections: 31
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-04593 Final10/14/201910/17/201910/17/2019 4:09:55 PMPPASS
INSTALLER BRANDAN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace only co ok- 5lb flue pass
MEC19-04006 Pressure Test10/17/201910/17/201910/17/2019 3:45:27 PMPPART
Phone #: ###-#### Inspection requested via web by MICHAEL BYERS- underground pvc piping for gas lines ok- depth and glue on pvc witnessed- no gas test at this time- ok to backfill all areas
MEC19-04438 Rough-in10/16/201910/17/201910/17/2019 3:26:42 PMPFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves-
1- need inert tape on gas line
2- need approved man j onsite
3- exhaust fan 2nd floor has trap in 4" duct needs to maintain grade from fan to roof
4- dryer duct can not run in 2x4 wall needs firred out or rerouted
5- ducting in crawl needs to maintain 4" off earth and bare metal needs insulated at zone damper

left correction notice front window
MEC19-04438 Pressure Test10/16/201910/17/201910/17/2019 3:23:53 PMPPART
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass tagged meter location- need inert tape on gas line penetration thru wall at meter location
MEC19-04578 Final10/14/201910/17/201910/17/2019 2:52:57 PMPPASS
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok
MEC19-04643 Rough-in10/17/201910/17/201910/17/2019 2:22:49 PMPFAIL
corrections made, please re-inspect, please come AM Phone #: ###-#### Inspection requested via web by Oleg Chervak
1- need approved man j onsite with right equipment brand and approved from city
2- insulation shield has gap off metal in attic insulation can come in contact with b vent for w/h
MEC19-04689 Final10/17/201910/17/201910/17/2019 2:02:37 PMPPASS
B j 2085730755. Homeowner will be gonna after 330.
Thanks. Call mark at ###-#### Inspection requested via web by william kerwin- furnace a/c coil co locking caps ok- gas test not needed under 10 feet
MEC19-04353 Final10/15/201910/17/201910/17/2019 1:46:14 PMPPASS
Please call Brianna in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace a/c coil co locking caps ok
MEC19-03935 Final10/15/201910/17/201910/17/2019 1:25:49 PMPFAIL
Please call Brenna prior to arrival. Phone #: ###-#### Inspection requested via web by Andrea Grigsby-
1- need locking caps on refrigerant ports
2- need to provide one additional co detector in hallway north end of house
3- need to witness flue test
4- combustion needs taken from outside furnace in bedroom
MEC19-03664 Conference10/17/201910/17/201910/17/2019 1:00:48 PMPPASS
duct blast test 1230pm- duct blast test pass
MEC19-03665 Conference10/17/201910/17/201910/17/2019 12:51:55 PMPPASS
duct blast test 1230pm- duct blast test pass
MEC19-03666 Conference10/16/201910/17/201910/17/2019 12:40:19 PMPPASS
Duct Blast 12:30 Phone #: ###-#### Inspection requested via web by Konrad Swartz- duct blast test pass
MEC19-03667 Conference10/16/201910/17/201910/17/2019 12:30:46 PMPPASS
Duct Blast 12:30 Phone #: ###-#### Inspection requested via web by Konrad Swartz- duct blast test pass
MEC19-03668 Conference10/16/201910/17/201910/17/2019 12:22:31 PMPPASS
Duct Blast 12:30 Phone #: ###-#### Inspection requested via web by Konrad Swartz- duct blast test pass
MEC19-04214 Rough-in10/16/201910/17/201910/17/2019 11:49:51 AMAPART
Grease duct inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- grease duct and oven clearances and install ok
MEC19-04005 Rough-in10/16/201910/17/201910/17/2019 10:57:04 AMAPASS
cover Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok- flex registers and insulation ok- ok for ceiling tiles
MEC19-03267 Final10/16/201910/17/201910/17/2019 10:44:31 AMPPASS
AC: 4141 Phone #: ###-#### Inspection requested via web by Gary Reeve- final ok- locking caps installed
MEC19-03135 Final10/16/201910/17/201910/17/2019 10:43:49 AMAPASS
Ac 4141 Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok- locking caps installed
MEC19-04391 Rough-in10/17/201910/17/201910/17/2019 10:23:01 AMAPASS
Please call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum- R/I ok- equipment not set check at final- left sticker in YMC folder on plan table
MEC19-01679 Conference10/16/201910/17/201910/17/2019 10:07:29 AMAPASS
Light test on grease duct- ###-####- 2- 16 feet 24 inch round lengths with 3 square accees ports light test ok
MEC19-04440 Final10/15/201910/17/201910/17/2019 9:17:40 AMACANC
Please inspect before 11 AM and call Carrie prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- homeowner sick will reschedule when she is feeling better- i gave her my card to call me
MEC19-04680 Rough-in10/17/201910/17/201910/17/2019 9:07:24 AMAPASS
Please call Cara 30 minutes in advance for access at ###-#### and call Ryan with any questions at ###-####. Thank you . Phone #: ###-#### Inspection requested via web by Rhonda Marcum- R/I ok on range duct and bath fan- call in final when hood installed
MEC19-01495 Final10/17/201910/17/201910/17/2019 8:56:06 AMAPASS
Please call before Inspection requested via web by Jimmy Acuna- final ok
MEC19-04618 Final10/17/201910/17/201910/17/2019 8:50:03 AMAPASS
locking caps installed on a/c
MEC19-04470 Pressure Test10/16/201910/17/201910/17/2019 8:43:54 AMAPASS
Re-inspection. Please call prior to arrival. Phone #: ###-#### Inspection requested via web by Jamee Shoecraft- gas piping and fireplace final ok
MEC19-04670 Final10/16/201910/17/201910/17/2019 8:29:39 AMAPASS
Call half hour before to meet // Edwin Phone #: ###-####- furnace only co ok
MEC19-04672 Rough-in10/16/201910/17/201910/17/2019 8:17:37 AMAPASS
cover Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok- need roof access at final
MEC18-05805 Mec-Aging Inspection10/17/201910/17/201910/17/2019 7:59:26 AM CANC
MEC18-05805 DOC - Permit Expired10/17/201910/17/201910/17/2019 7:59:20 AMAPASS
no calls- no activity
MEC19-01172 Mec-Aging Inspection10/17/201910/17/201910/17/2019 7:58:41 AM FAIL
needs called in for final inspection by contractor
MEC19-02994 Final10/16/201910/17/201910/16/2019 2:58:33 PMAPASS
Claud Phone #: ###-####