MEC19-04593
| Final | 10/14/2019 | 10/17/2019 | 10/17/2019 4:09:55 PM | P | PASS |
|
|
INSTALLER BRANDAN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace only co ok- 5lb flue pass
|
MEC19-04006
| Pressure Test | 10/17/2019 | 10/17/2019 | 10/17/2019 3:45:27 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by MICHAEL BYERS- underground pvc piping for gas lines ok- depth and glue on pvc witnessed- no gas test at this time- ok to backfill all areas
|
MEC19-04438
| Rough-in | 10/16/2019 | 10/17/2019 | 10/17/2019 3:26:42 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- 1- need inert tape on gas line 2- need approved man j onsite 3- exhaust fan 2nd floor has trap in 4" duct needs to maintain grade from fan to roof 4- dryer duct can not run in 2x4 wall needs firred out or rerouted 5- ducting in crawl needs to maintain 4" off earth and bare metal needs insulated at zone damper
left correction notice front window
|
MEC19-04438
| Pressure Test | 10/16/2019 | 10/17/2019 | 10/17/2019 3:23:53 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass tagged meter location- need inert tape on gas line penetration thru wall at meter location
|
MEC19-04578
| Final | 10/14/2019 | 10/17/2019 | 10/17/2019 2:52:57 PM | P | PASS |
|
|
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok
|
MEC19-04643
| Rough-in | 10/17/2019 | 10/17/2019 | 10/17/2019 2:22:49 PM | P | FAIL |
|
|
corrections made, please re-inspect, please come AM Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- need approved man j onsite with right equipment brand and approved from city 2- insulation shield has gap off metal in attic insulation can come in contact with b vent for w/h
|
MEC19-04689
| Final | 10/17/2019 | 10/17/2019 | 10/17/2019 2:02:37 PM | P | PASS |
|
|
B j 2085730755. Homeowner will be gonna after 330. Thanks. Call mark at ###-#### Inspection requested via web by william kerwin- furnace a/c coil co locking caps ok- gas test not needed under 10 feet
|
MEC19-04353
| Final | 10/15/2019 | 10/17/2019 | 10/17/2019 1:46:14 PM | P | PASS |
|
|
Please call Brianna in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace a/c coil co locking caps ok
|
MEC19-03935
| Final | 10/15/2019 | 10/17/2019 | 10/17/2019 1:25:49 PM | P | FAIL |
|
|
Please call Brenna prior to arrival. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- 1- need locking caps on refrigerant ports 2- need to provide one additional co detector in hallway north end of house 3- need to witness flue test 4- combustion needs taken from outside furnace in bedroom
|
MEC19-03664
| Conference | 10/17/2019 | 10/17/2019 | 10/17/2019 1:00:48 PM | P | PASS |
|
|
duct blast test 1230pm- duct blast test pass
|
MEC19-03665
| Conference | 10/17/2019 | 10/17/2019 | 10/17/2019 12:51:55 PM | P | PASS |
|
|
duct blast test 1230pm- duct blast test pass
|
MEC19-03666
| Conference | 10/16/2019 | 10/17/2019 | 10/17/2019 12:40:19 PM | P | PASS |
|
|
Duct Blast 12:30 Phone #: ###-#### Inspection requested via web by Konrad Swartz- duct blast test pass
|
MEC19-03667
| Conference | 10/16/2019 | 10/17/2019 | 10/17/2019 12:30:46 PM | P | PASS |
|
|
Duct Blast 12:30 Phone #: ###-#### Inspection requested via web by Konrad Swartz- duct blast test pass
|
MEC19-03668
| Conference | 10/16/2019 | 10/17/2019 | 10/17/2019 12:22:31 PM | P | PASS |
|
|
Duct Blast 12:30 Phone #: ###-#### Inspection requested via web by Konrad Swartz- duct blast test pass
|
MEC19-04214
| Rough-in | 10/16/2019 | 10/17/2019 | 10/17/2019 11:49:51 AM | A | PART |
|
|
Grease duct inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- grease duct and oven clearances and install ok
|
MEC19-04005
| Rough-in | 10/16/2019 | 10/17/2019 | 10/17/2019 10:57:04 AM | A | PASS |
|
|
cover Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok- flex registers and insulation ok- ok for ceiling tiles
|
MEC19-03267
| Final | 10/16/2019 | 10/17/2019 | 10/17/2019 10:44:31 AM | P | PASS |
|
|
AC: 4141 Phone #: ###-#### Inspection requested via web by Gary Reeve- final ok- locking caps installed
|
MEC19-03135
| Final | 10/16/2019 | 10/17/2019 | 10/17/2019 10:43:49 AM | A | PASS |
|
|
Ac 4141 Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok- locking caps installed
|
MEC19-04391
| Rough-in | 10/17/2019 | 10/17/2019 | 10/17/2019 10:23:01 AM | A | PASS |
|
|
Please call Ryan with any questions at ###-####. Thank you Phone #: ###-#### Inspection requested via web by Rhonda Marcum- R/I ok- equipment not set check at final- left sticker in YMC folder on plan table
|
MEC19-01679
| Conference | 10/16/2019 | 10/17/2019 | 10/17/2019 10:07:29 AM | A | PASS |
|
|
Light test on grease duct- ###-####- 2- 16 feet 24 inch round lengths with 3 square accees ports light test ok
|
MEC19-04440
| Final | 10/15/2019 | 10/17/2019 | 10/17/2019 9:17:40 AM | A | CANC |
|
|
Please inspect before 11 AM and call Carrie prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- homeowner sick will reschedule when she is feeling better- i gave her my card to call me
|
MEC19-04680
| Rough-in | 10/17/2019 | 10/17/2019 | 10/17/2019 9:07:24 AM | A | PASS |
|
|
Please call Cara 30 minutes in advance for access at ###-#### and call Ryan with any questions at ###-####. Thank you . Phone #: ###-#### Inspection requested via web by Rhonda Marcum- R/I ok on range duct and bath fan- call in final when hood installed
|
MEC19-01495
| Final | 10/17/2019 | 10/17/2019 | 10/17/2019 8:56:06 AM | A | PASS |
|
|
Please call before Inspection requested via web by Jimmy Acuna- final ok
|
MEC19-04618
| Final | 10/17/2019 | 10/17/2019 | 10/17/2019 8:50:03 AM | A | PASS |
|
|
locking caps installed on a/c
|
MEC19-04470
| Pressure Test | 10/16/2019 | 10/17/2019 | 10/17/2019 8:43:54 AM | A | PASS |
|
|
Re-inspection. Please call prior to arrival. Phone #: ###-#### Inspection requested via web by Jamee Shoecraft- gas piping and fireplace final ok
|
MEC19-04670
| Final | 10/16/2019 | 10/17/2019 | 10/17/2019 8:29:39 AM | A | PASS |
|
|
Call half hour before to meet // Edwin Phone #: ###-####- furnace only co ok
|
MEC19-04672
| Rough-in | 10/16/2019 | 10/17/2019 | 10/17/2019 8:17:37 AM | A | PASS |
|
|
cover Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok- need roof access at final
|
MEC18-05805
| Mec-Aging Inspection | 10/17/2019 | 10/17/2019 | 10/17/2019 7:59:26 AM | | CANC |
|
|
|
MEC18-05805
| DOC - Permit Expired | 10/17/2019 | 10/17/2019 | 10/17/2019 7:59:20 AM | A | PASS |
|
|
no calls- no activity
|
MEC19-01172
| Mec-Aging Inspection | 10/17/2019 | 10/17/2019 | 10/17/2019 7:58:41 AM | | FAIL |
|
|
needs called in for final inspection by contractor
|
MEC19-02994
| Final | 10/16/2019 | 10/17/2019 | 10/16/2019 2:58:33 PM | A | PASS |
|
|
Claud Phone #: ###-####
|