MEC19-04508
| Final | 10/18/2019 | 10/22/2019 | 10/22/2019 3:57:31 PM | P | PASS |
|
|
Please call Chris in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace only co ok
|
MEC19-04560
| Final | 10/22/2019 | 10/22/2019 | 10/22/2019 3:40:00 PM | P | PASS |
|
|
locking caps installed
|
MEC19-04405
| Pressure Test | 10/21/2019 | 10/22/2019 | 10/22/2019 3:37:17 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Chris Field- 20lb gas pass from new meter location to old meter location exterior of house
|
MEC19-04544
| Rough-in | 10/21/2019 | 10/22/2019 | 10/22/2019 3:18:57 PM | P | FAIL |
|
|
we have a few quality control items to take care in the morning. please do inspection afternoon. thx. -Peter Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- gas test fail 2- need to fix all rips and tears in arma flex in wall and attic 3- need to secure plastic around fireplace thimble and top of pipe needs 3" clearance from pipe to wood framing needs reframed 4- all exposed insulation in attic on flex duct needs vapor barrier and installed per installation instructions 5- b vent in 2nd floor chase and attic off furnace needs secured
left notice back window
|
MEC19-04544
| Pressure Test | 10/22/2019 | 10/22/2019 | 10/22/2019 3:15:13 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge below 20psi
|
MEC19-03783
| Final | 10/21/2019 | 10/22/2019 | 10/22/2019 3:05:05 PM | P | FAIL |
|
|
Garage code 0425 Phone #: ###-#### Inspection requested via web by Oleg Chervak- need duct blast and airbalance reports onsite- a/c ports need locking caps
|
MEC19-04774
| Rough-in | 10/22/2019 | 10/22/2019 | 10/22/2019 2:39:43 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I ok
|
MEC19-04774
| Pressure Test | 10/22/2019 | 10/22/2019 | 10/22/2019 2:39:29 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter location
|
MEC19-04775
| Rough-in | 10/22/2019 | 10/22/2019 | 10/22/2019 2:39:08 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I ok
|
MEC19-04775
| Pressure Test | 10/22/2019 | 10/22/2019 | 10/22/2019 2:38:51 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter location
|
MEC19-04643
| Rough-in | 10/22/2019 | 10/22/2019 | 10/22/2019 2:13:16 PM | P | PASS |
|
|
we have approved manual on site now, please re-inspect Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I ok
|
MEC19-04629
| Final | 10/22/2019 | 10/22/2019 | 10/22/2019 2:06:35 PM | P | PASS |
|
|
furnace a/c coil co locking caps ok
|
MEC19-02713
| Pressure Test | 10/22/2019 | 10/22/2019 | 10/22/2019 1:54:12 PM | P | PASS |
|
|
if questions call Chad @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann- 60lb gas pass x 4 off existing systems
|
MEC19-02115
| Final | 10/21/2019 | 10/22/2019 | 10/22/2019 1:53:41 PM | P | PASS |
|
|
Early in the P.M. if possible, Thank you !! Phone #: ###-#### Inspection requested via web by Bruce Lacy- final ok
|
MEC19-04037
| Rough-in | 10/21/2019 | 10/22/2019 | 10/22/2019 1:30:04 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves 1- need city approved man j onsite 2- gas gauge doesnt zero out 3- 6" fresh air can not come from R/A can needs tied into R/A plenum at furnace
left notice front window
|
MEC19-04037
| Pressure Test | 10/21/2019 | 10/22/2019 | 10/22/2019 1:28:45 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- gauge doesnt zero out
|
MEC19-04762
| Conference | 10/22/2019 | 10/22/2019 | 10/22/2019 1:28:23 PM | P | CANC |
|
|
should have been R/I
|
MEC19-04762
| Rough-in | 10/22/2019 | 10/22/2019 | 10/22/2019 1:28:10 PM | P | PASS |
|
|
firep[lace R/I ok
|
MEC19-02712
| Pressure Test | 10/22/2019 | 10/22/2019 | 10/22/2019 12:42:41 PM | P | PASS |
|
|
if questions call Chad @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann- 60lb gas pass x 2
|
MEC19-03821
| Final | 10/22/2019 | 10/22/2019 | 10/22/2019 12:42:08 PM | P | PASS |
|
|
if questions call Chad @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
|
MEC19-03892
| Final | 10/22/2019 | 10/22/2019 | 10/22/2019 12:41:51 PM | P | PASS |
|
|
if questions call Chad @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann
|
MEC19-03367
| Final | 10/22/2019 | 10/22/2019 | 10/22/2019 12:02:26 PM | P | NH |
|
|
Outside garage connections Inspection requested via web by Tobi Wilson- no one home- can not access premise with out homeowner or contractor onsite- gates installed
|
MEC19-04751
| Rough-in | 10/21/2019 | 10/22/2019 | 10/22/2019 11:21:09 AM | A | FAIL |
|
|
Acess code 7777 Inspection requested via web by william kerwin 1- need approved man j onsite approved from city none found 2- need ladder provided by contractor to access furn/coil in attic 3- need fireplace instructions readily available behind glass 4- Range ducting on this unit ???
left correction n otice front window
|
MEC19-04753
| Rough-in | 10/21/2019 | 10/22/2019 | 10/22/2019 11:19:05 AM | A | FAIL |
|
|
Codeb7777 Inspection requested via web by william kerwin 1- need approved man j from city onsite 2- need ladder provided by contractor to access furn/coil in attic 3- need transfer in bedroom 4- need to seal all exhaust fan connections where metal fitting ties onto plastic 5- b vent in attic does not have 1" clearance to truss and roof and nylon strap laying against it 6- range duct not installed
left correction notice front window
|
MEC19-04753
| Pressure Test | 10/21/2019 | 10/22/2019 | 10/22/2019 11:16:34 AM | A | PASS |
|
|
Codeb7777 Inspection requested via web by william kerwin- 20lb gas pass tagged meter location
|
MEC19-04751
| Pressure Test | 10/21/2019 | 10/22/2019 | 10/22/2019 11:16:10 AM | A | PASS |
|
|
Acess code 7777 Inspection requested via web by william kerwin- 20lb gas pass tagged meter location
|
MEC19-04750
| Rough-in | 10/21/2019 | 10/22/2019 | 10/22/2019 10:53:56 AM | A | FAIL |
|
|
Code 7777. Inspection requested via web by william kerwin- 3 bath fans ok- need fireplace installation manual readily accessible behind glass
|
MEC19-04750
| Pressure Test | 10/21/2019 | 10/22/2019 | 10/22/2019 10:53:16 AM | A | PASS |
|
|
Code 7777 Inspection requested via web by william kerwin- 20lb gas pass tagged meter location
|
MEC19-04757
| Pressure Test | 10/21/2019 | 10/22/2019 | 10/22/2019 10:41:31 AM | A | FAIL |
|
|
Code 7777 Inspection requested via web by william kerwin- gauge below 20psi
|
MEC19-03269
| Final | 10/21/2019 | 10/22/2019 | 10/22/2019 10:27:59 AM | P | PASS |
|
|
AC: 4141 Phone #: ###-#### Inspection requested via web by Gary Reeves
|
MEC19-03301
| Final | 10/21/2019 | 10/22/2019 | 10/22/2019 10:21:09 AM | A | PASS |
|
|
kai ###-#### manual in pantry w/remote Phone #: ###-#### Inspection requested via web by Mike Almanza- final ok
|
MEC19-03579
| Final | 10/21/2019 | 10/22/2019 | 10/22/2019 10:11:28 AM | A | CANC |
|
|
Ceilimg inspection , as early as possible. Thanks . Code on back gas meter 4955 Inspection requested via web by william kerwin- this should have been R/I inspection-
|
MEC19-03579
| Rough-in | 10/22/2019 | 10/22/2019 | 10/22/2019 10:10:34 AM | A | PASS |
|
|
Ceilimg inspection , as early as possible. Thanks . Code on back gas meter 4955 Inspection requested via web by william kerwin- R/I ok on registers flwx and insulation- ok to install ceiling tiles- call in final when ready- will need roof access at final
|
MEC19-04762
| Rough-in | 10/21/2019 | 10/22/2019 | 10/22/2019 9:47:39 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Brian Preece- per 3.2 diagram page 28 shows minimum 3 inch clearance to framing to flue only has 2 inches
|
MEC19-04594
| Final | 10/17/2019 | 10/22/2019 | 10/22/2019 9:20:37 AM | A | PASS |
|
|
This is a Flue Pressure and Final Inspect. Please meet our installer at home at 9:30 AM. Contact for Right Now is Mary ###-####
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co locking caps ok- 5lb flue test pass
|
MEC19-03560
| Final | 10/18/2019 | 10/22/2019 | 10/22/2019 8:49:40 AM | A | PASS |
|
|
DANNY SEASTROM ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- 1 fireplace 1 log set co ok- gas piping ok
|
MEC19-04560
| Final | 10/16/2019 | 10/22/2019 | 10/22/2019 8:32:58 AM | A | FAIL |
|
|
Please call Roger or Carol Johnston (###-####) 30 minutes prior to appointment, Thank you. Phone #: ###-#### Inspection requested via web by Michele Johnson- a/c coil co ok- need locking caps on a/c ports
|
MEC19-03321
| Final | 10/21/2019 | 10/22/2019 | 10/22/2019 8:08:34 AM | A | PASS |
|
|
vinnie ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
|