Inspections for the day of: Wednesday, October 23, 2019.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-03783 Final10/22/201910/23/201910/23/2019 3:48:07 PMPPASS
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- final ok
MEC19-04544 Rough-in10/22/201910/23/201910/23/2019 3:38:32 PMPFAIL
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- not all corrections made see notice back window
MEC19-04544 Pressure Test10/23/201910/23/201910/23/2019 3:38:00 PMPFAIL
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge doesnt zero out- need to add pressure test to inspections not just R/I
MEC19-04783 Pressure Test10/22/201910/23/201910/23/2019 3:19:31 PMPFAIL
David Phone #: ###-####- need open tee between the 2 shut off valves per code IRC G2417.1.4 in garage- needs to be 60lb gas test on 100lb gauge max since meter is 2# system and gauge didnt zero out
MEC19-04787 Final10/22/201910/23/201910/23/2019 3:03:19 PMPPASS
Please call Dave to ensure install is complete. ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Rick Borg- furnace a/c coil co locking caps ok
MEC19-04335 Conference10/23/201910/23/201910/23/2019 2:39:41 PMPDONE
Inspect the bathroom ducting and fire wall penetration. 208 801 3772 Shawn general on the job Phone #: ###-#### Inspection requested via web by jeff jedlick- went over fire damper installation instructions- needs sleeve extending out on each side of wall- call in R/I when ready
MEC19-04750 Rough-in10/23/201910/23/201910/23/2019 1:20:58 PMPFAIL
Code 7777 Phone #: ###-#### Inspection requested via web by Teresa Costello- need horizontal framing above fireplace installed per installation instructions
MEC19-04751 Rough-in10/23/201910/23/201910/23/2019 1:20:05 PMPFAIL
Code 7777
Phone #: ###-#### Inspection requested via web by Teresa Costello
1- b vent for water heater is touching R/A ducting in attic
2- need horizontal framing above fireplace per installation instructions
MEC19-04753 Rough-in10/23/201910/23/201910/23/2019 1:18:37 PMPPASS
Code 7777 Phone #: ###-#### Inspection requested via web by Teresa Costello- R/I ok
MEC19-04757 Pressure Test10/23/201910/23/201910/23/2019 1:18:19 PMPFAIL
code 7777 Phone #: ###-#### Inspection requested via web by Teresa Costello- gauge below 20psi
MEC19-04232 Final10/23/201910/23/201910/23/2019 12:38:16 PMPNH
Inspection requested via web by anthony allen- no one home- rang doorbell and knocked- no access- can not enter property with out homeowner or contractor onsite- 12:38pm
MEC19-03777 Final10/23/201910/23/201910/23/2019 11:41:13 AMPCANC
Phone #: ###-#### Inspection requested via web by jamie berg- per phone call with Buck will reschedule
MEC19-03367 Final10/22/201910/23/201910/23/2019 11:20:47 AMAFAIL
Please call prior to going so contractor can meet you onsite Phone #: ###-#### Inspection requested via web by Tobi Wilson- need pvc sleeve thru concrete around gas piping at pool heater location- Tobi was onsite
MEC19-04561 Final10/16/201910/23/201910/23/2019 11:04:06 AMAPASS
Please call Connie Tank (###-####) 30 minutes prior to appointment, Thank you Phone #: ###-#### Inspection requested via web by Michele Johnson- furnace only co ok
MEC19-04342 Rough-in10/22/201910/23/201910/23/2019 10:51:38 AMAPASS
GARI ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
MEC19-04100 Final10/23/201910/23/201910/23/2019 10:39:51 AMAPASS
final ok- card signed
MEC19-04100 Rough-in10/22/201910/23/201910/23/2019 10:39:03 AMAPASS
call ahead // Tom Phone #: ###-####- R/I ok
MEC19-04773 Rough-in10/22/201910/23/201910/23/2019 10:02:52 AMAFAIL
Phone #: ###-#### Inspection requested via web by Kim Evans
1- need to seal all spotwelds on r/a and supply boots
2- no gas on test
3- dryer duct needs ran on r/i
4- exhaust fan ducting not ran and need to add 3 to permit and pay fee
5- will need fue test witnessed since intake and exhaust were rerouted
6- transfers for bedrooms and laundry room??

left notice front window
MEC19-04702 Rough-in10/17/201910/23/201910/23/2019 9:16:29 AMAFAIL
Please schedule between 9 am - 6 pm and call Cheyenne or office (###-####) to let them know your own your way, Thank you Phone #: ###-#### Inspection requested via web by Michele Johnson- outside condensate drain needs ran in 3/4"pvc flex tubing not approved material- need electrical permit issued for condenser outside- send pics of pvc condensate for reinspect
MEC19-03268 Final10/22/201910/23/201910/23/2019 9:03:05 AMAPASS
Duct blast witness at 9am, thanks Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok- duct blast test pass- locking caps installed on a/c
MEC19-04405 Final10/23/201910/23/201910/23/2019 8:41:01 AMAPASS
20lb gas whole system
MEC18-02862 Final10/22/201910/23/201910/23/2019 8:32:50 AMAPASS
Patrick Phone #: ###-####- final ok