MEC19-03783
| Final | 10/22/2019 | 10/23/2019 | 10/23/2019 3:48:07 PM | P | PASS |
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- final ok
|
MEC19-04544
| Rough-in | 10/22/2019 | 10/23/2019 | 10/23/2019 3:38:32 PM | P | FAIL |
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- not all corrections made see notice back window
|
MEC19-04544
| Pressure Test | 10/23/2019 | 10/23/2019 | 10/23/2019 3:38:00 PM | P | FAIL |
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge doesnt zero out- need to add pressure test to inspections not just R/I
|
MEC19-04783
| Pressure Test | 10/22/2019 | 10/23/2019 | 10/23/2019 3:19:31 PM | P | FAIL |
|
|
David Phone #: ###-####- need open tee between the 2 shut off valves per code IRC G2417.1.4 in garage- needs to be 60lb gas test on 100lb gauge max since meter is 2# system and gauge didnt zero out
|
MEC19-04787
| Final | 10/22/2019 | 10/23/2019 | 10/23/2019 3:03:19 PM | P | PASS |
|
|
Please call Dave to ensure install is complete. ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Rick Borg- furnace a/c coil co locking caps ok
|
MEC19-04335
| Conference | 10/23/2019 | 10/23/2019 | 10/23/2019 2:39:41 PM | P | DONE |
|
|
Inspect the bathroom ducting and fire wall penetration. 208 801 3772 Shawn general on the job Phone #: ###-#### Inspection requested via web by jeff jedlick- went over fire damper installation instructions- needs sleeve extending out on each side of wall- call in R/I when ready
|
MEC19-04750
| Rough-in | 10/23/2019 | 10/23/2019 | 10/23/2019 1:20:58 PM | P | FAIL |
|
|
Code 7777 Phone #: ###-#### Inspection requested via web by Teresa Costello- need horizontal framing above fireplace installed per installation instructions
|
MEC19-04751
| Rough-in | 10/23/2019 | 10/23/2019 | 10/23/2019 1:20:05 PM | P | FAIL |
|
|
Code 7777 Phone #: ###-#### Inspection requested via web by Teresa Costello 1- b vent for water heater is touching R/A ducting in attic 2- need horizontal framing above fireplace per installation instructions
|
MEC19-04753
| Rough-in | 10/23/2019 | 10/23/2019 | 10/23/2019 1:18:37 PM | P | PASS |
|
|
Code 7777 Phone #: ###-#### Inspection requested via web by Teresa Costello- R/I ok
|
MEC19-04757
| Pressure Test | 10/23/2019 | 10/23/2019 | 10/23/2019 1:18:19 PM | P | FAIL |
|
|
code 7777 Phone #: ###-#### Inspection requested via web by Teresa Costello- gauge below 20psi
|
MEC19-04232
| Final | 10/23/2019 | 10/23/2019 | 10/23/2019 12:38:16 PM | P | NH |
|
|
Inspection requested via web by anthony allen- no one home- rang doorbell and knocked- no access- can not enter property with out homeowner or contractor onsite- 12:38pm
|
MEC19-03777
| Final | 10/23/2019 | 10/23/2019 | 10/23/2019 11:41:13 AM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by jamie berg- per phone call with Buck will reschedule
|
MEC19-03367
| Final | 10/22/2019 | 10/23/2019 | 10/23/2019 11:20:47 AM | A | FAIL |
|
|
Please call prior to going so contractor can meet you onsite Phone #: ###-#### Inspection requested via web by Tobi Wilson- need pvc sleeve thru concrete around gas piping at pool heater location- Tobi was onsite
|
MEC19-04561
| Final | 10/16/2019 | 10/23/2019 | 10/23/2019 11:04:06 AM | A | PASS |
|
|
Please call Connie Tank (###-####) 30 minutes prior to appointment, Thank you Phone #: ###-#### Inspection requested via web by Michele Johnson- furnace only co ok
|
MEC19-04342
| Rough-in | 10/22/2019 | 10/23/2019 | 10/23/2019 10:51:38 AM | A | PASS |
|
|
GARI ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
|
MEC19-04100
| Final | 10/23/2019 | 10/23/2019 | 10/23/2019 10:39:51 AM | A | PASS |
|
|
final ok- card signed
|
MEC19-04100
| Rough-in | 10/22/2019 | 10/23/2019 | 10/23/2019 10:39:03 AM | A | PASS |
|
|
call ahead // Tom Phone #: ###-####- R/I ok
|
MEC19-04773
| Rough-in | 10/22/2019 | 10/23/2019 | 10/23/2019 10:02:52 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kim Evans 1- need to seal all spotwelds on r/a and supply boots 2- no gas on test 3- dryer duct needs ran on r/i 4- exhaust fan ducting not ran and need to add 3 to permit and pay fee 5- will need fue test witnessed since intake and exhaust were rerouted 6- transfers for bedrooms and laundry room??
left notice front window
|
MEC19-04702
| Rough-in | 10/17/2019 | 10/23/2019 | 10/23/2019 9:16:29 AM | A | FAIL |
|
|
Please schedule between 9 am - 6 pm and call Cheyenne or office (###-####) to let them know your own your way, Thank you Phone #: ###-#### Inspection requested via web by Michele Johnson- outside condensate drain needs ran in 3/4"pvc flex tubing not approved material- need electrical permit issued for condenser outside- send pics of pvc condensate for reinspect
|
MEC19-03268
| Final | 10/22/2019 | 10/23/2019 | 10/23/2019 9:03:05 AM | A | PASS |
|
|
Duct blast witness at 9am, thanks Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok- duct blast test pass- locking caps installed on a/c
|
MEC19-04405
| Final | 10/23/2019 | 10/23/2019 | 10/23/2019 8:41:01 AM | A | PASS |
|
|
20lb gas whole system
|
MEC18-02862
| Final | 10/22/2019 | 10/23/2019 | 10/23/2019 8:32:50 AM | A | PASS |
|
|
Patrick Phone #: ###-####- final ok
|