MEC19-04905
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 3:40:14 PM | P | PASS |
|
|
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace only co ok
|
PLM19-04671
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 3:38:03 PM | P | PASS |
|
|
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- water heater co ok
|
MEC19-03404
| Final | 10/31/2019 | 10/31/2019 | 10/31/2019 2:54:20 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Konrad Swartz- final ok- locking caps installed on a/c
|
MEC19-03402
| Final | 10/31/2019 | 10/31/2019 | 10/31/2019 2:53:08 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Konrad Swartz- final ok- locking caps installed on a/c
|
MEC19-03401
| Final | 10/31/2019 | 10/31/2019 | 10/31/2019 2:52:41 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Konrad Swartz- final ok- locking caps installed on a/c
|
MEC19-03400
| Final | 10/31/2019 | 10/31/2019 | 10/31/2019 2:51:47 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Konrad Swartz- final ok- locking caps on a/c
|
MEC19-03399
| Final | 10/31/2019 | 10/31/2019 | 10/31/2019 2:50:22 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Konrad Swartz- final ok- locking caps installed on a/c
|
MEC19-03398
| Final | 10/31/2019 | 10/31/2019 | 10/31/2019 2:49:08 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Konrad Swartz- final ok- locking caps installed on a/c
|
MEC19-02931
| Final | 10/31/2019 | 10/31/2019 | 10/31/2019 2:48:40 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Konrad Swartz- final ok- locking caps installed on a/c
|
MEC19-04801
| Rough-in | 10/30/2019 | 10/31/2019 | 10/31/2019 2:12:51 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I ok on HVAC and FIREPLACE
|
MEC19-04883
| Final | 10/31/2019 | 10/31/2019 | 10/31/2019 1:39:28 PM | P | PASS |
|
|
Tanner ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace in crawl a/c coil co locking caps ok
|
MEC19-04817
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 12:55:43 PM | P | PASS |
|
|
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co gas piping flue locking caps ok
|
MEC19-02727
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 11:03:28 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Andrea Creek 1- need locking caps on both a/c service ports 2- need airbalance report for both units onsite none found 3- need sediment trap between gas shut off valve and furnace both units 4-water heater flue in laundry room needs 6" clearance to single wall pipe from sheetrock or install b vent 5- missing R/A grill 2nd floor hallway
|
MEC19-03971
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 10:35:31 AM | A | PASS |
|
|
PAT IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- final ok
|
MEC19-04849
| Rough-in | 10/30/2019 | 10/31/2019 | 10/31/2019 10:01:20 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kristy Watson 1- gas gauge does not zero out- replace 2- need to seal all spotwelds on all R/A and supply boots 3- man j shows 2 supply runs in bedrooms 2&3 only has one installed- need to add per man j or resubmit to city for approval as installed 4- exposed insulation on flex duct in crawl needs vapor barrier installed 5- main supply trunk in crawl pinched off due to plumbing drain at crawl entrance
left notice front window
|
MEC19-04849
| Pressure Test | 10/31/2019 | 10/31/2019 | 10/31/2019 9:56:20 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kristy Watson- gauge doesnt zero out- replace
|
MEC19-04909
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 9:51:45 AM | A | CANC |
|
|
This is a roof top unit Phone #: ###-#### Inspection requested via web by Aaron Toomey- per phone call not ready- need to change from single family to commerial on this permit before final inspection
|
MEC19-01484
| Mec-Aging Inspection | 10/31/2019 | 10/31/2019 | 10/31/2019 9:28:02 AM | | CANC |
|
|
talked with Mike about having GC schedule this inspection- bld has passed with out this inspection completed
|
MEC19-04887
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 9:21:41 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette- elecric furnace heat pump coil co locking caps ok
|
MEC19-03798
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 8:53:49 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Konrad Swartz Inspection cancelled from web by: Konrad Swartz
|
MEC19-03799
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 8:53:47 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Konrad Swartz Inspection cancelled from web by: Konrad Swartz
|
MEC19-03801
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 8:53:45 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Konrad Swartz Inspection cancelled from web by: Konrad Swartz
|
MEC19-04067
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 8:53:43 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Konrad Swartz Inspection cancelled from web by: Konrad Swartz
|
MEC19-04068
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 8:53:41 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Konrad Swartz Inspection cancelled from web by: Konrad Swartz
|
MEC19-04069
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 8:53:37 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Konrad Swartz Inspection cancelled from web by: Konrad Swartz
|
MEC19-04070
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 8:53:35 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Konrad Swartz Inspection cancelled from web by: Konrad Swartz
|
MEC19-04071
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 8:53:33 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Konrad Swartz Inspection cancelled from web by: Konrad Swartz
|
MEC19-04072
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 8:53:31 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Konrad Swartz Inspection cancelled from web by: Konrad Swartz
|
MEC19-04073
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 8:53:29 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Konrad Swartz Inspection cancelled from web by: Konrad Swartz
|
MEC19-04885
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 8:47:38 AM | A | FAIL |
|
|
Call ahead to owner if you want, Bill @ ###-#### or Kevin (QHC) @ Phone #: ###-#### Inspection requested via web by Kevin Pratley- electric furnace coil heat pump co ok- need locking caps on a/c service ports- send pic for reinspect
|
MEC19-04857
| Final | 10/30/2019 | 10/31/2019 | 10/31/2019 8:16:43 AM | A | FAIL |
|
|
Please inspect before 9:30 Phone #: ###-#### Inspection requested via web by Mary LaFayette- need to schedule a flue test witness
|
MEC18-05974
| Mec-Aging Inspection | 10/31/2019 | 10/31/2019 | 10/31/2019 7:58:44 AM | | CANC |
|
|
|
MEC18-05974
| DOC - Permit Expired | 10/31/2019 | 10/31/2019 | 10/31/2019 7:58:37 AM | A | PASS |
|
|
no calls no activity
|
MEC19-01454
| Mec-Aging Inspection | 10/31/2019 | 10/31/2019 | 10/31/2019 7:57:46 AM | | FAIL |
|
|
contractor needs to schedule inspection no one home last time- permit will expire next aging if no activity
|
MEC19-03375
| Final | 10/30/2019 | 10/31/2019 | 10/30/2019 3:23:30 PM | P | CANC |
|
|
Mechanical Gas Fireplace Final Inspection. Manual is in kitchen drawer. Garage Code: 3162 Phone #: ###-#### Inspection requested via web by Dan Otero- completed 10-30-19
|