Inspections for the day of: Tuesday, October 9, 2018.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-04746 Final10/4/201810/9/201810/9/2018 3:58:40 PMPPASS
Please inspect after 3:30 - Angela ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
MEC18-04856 Rough-in10/9/201810/9/201810/9/2018 3:19:37 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak- Hvac R/I ok
MEC18-04856 Rough-in10/9/201810/9/201810/9/2018 3:19:15 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak- fireplace R/I ok
MEC18-04827 Final10/5/201810/9/201810/9/2018 2:56:07 PMPPASS
installer Travis ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok
MEC18-02516 Conference10/9/201810/9/201810/9/2018 1:49:58 PMPDONE
Don Phone #: ###-####- discussed gas piping and unit heater installation
MEC18-03291 Final10/9/201810/9/201810/9/2018 1:13:36 PMPPASS
final ok
MEC18-03291 Conference10/9/201810/9/201810/9/2018 1:13:01 PMPPASS
final ok
MEC18-04599 Rough-in10/8/201810/9/201810/9/2018 11:42:09 AMAPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok
MEC18-04599 Pressure Test10/8/201810/9/201810/9/2018 11:41:53 AMAPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass
MEC18-03406 Rough-in10/9/201810/9/201810/9/2018 11:17:01 AMAPASS
look at R/A in wall- R/I ok- ok to install all R/A registers in plenum walls
MEC18-04793 Rough-in10/8/201810/9/201810/9/2018 10:57:53 AMAFAIL
rough Phone #: ###-#### Inspection requested via web by Brandon Sorensen- ducting in crawl and ceiling needs insulated to pass R/I- need to install 2x4 in wall 2nd floor below wall exhaust fan- rest is good
MEC18-04793 Pressure Test10/8/201810/9/201810/9/2018 10:54:50 AMAFAIL
pressure test Phone #: ###-#### Inspection requested via web by Brandon Sorensen- gauge at zero psi-
MEC18-04798 Pressure Test10/8/201810/9/201810/9/2018 10:38:02 AMAPASS
Please call customer (Julie Robinson) 30 min prior to arrival at ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- 20lb gas pass
MEC18-04816 Rough-in10/8/201810/9/201810/9/2018 10:26:06 AMAPASS
TYLER ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
MEC18-04856 Rough-in10/8/201810/9/201810/9/2018 10:07:55 AMAFAIL
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- insulation shield on water heater b vent needs to extend to roof pitch- crawl needs completed- need to seal dryer duct to termination box- R/A for bedroom 2 & 3 not per man j needs to tie into 18" round ducting not at register can off 14" round- reinspection fee issued for ongoing issues on new construction R/Is- left correction notice front entry window
MEC18-04856 Pressure Test10/8/201810/9/201810/9/2018 9:59:04 AMAPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass
MEC18-04810 Final10/9/201810/9/201810/9/2018 9:23:46 AMAPASS
gas piping ok- final ok co ok
MEC18-04810 Pressure Test10/8/201810/9/201810/9/2018 9:22:21 AMAPASS
Please call Howard at ###-#### prior to arrival
Thank you Phone #: ###-#### Inspection requested via web by chris mcdaniel- 20lb gas pass
MEC18-04843 Rough-in10/8/201810/9/201810/9/2018 8:56:08 AMAFAIL
Garage Code: 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- gas gauge below 20psi- need to seal all resiter boots on inside- need approved man j onsite one there wasnt approved- need ladder provided to access furnace/coil in attic- need nail plate installed on 3/4"pvc drain at ceiling and floor 1st and 2nd floors west side of house- left correction notice front entry window
MEC18-04843 Pressure Test10/8/201810/9/201810/9/2018 8:53:03 AMAFAIL
Garage Code: 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- gauge below 20psi
MEC18-04719 Pressure Test10/8/201810/9/201810/9/2018 8:20:06 AMAFAIL
Please contact Ken at ###-#### for information on pressure test. Phone #: ###-#### Inspection requested via web by Jamie Scibior- gauge wont zero out- please install temp shutoff valve before gauge so can be used at pressure rather than draining whole system
MEC18-04086 Final10/4/201810/9/201810/8/2018 8:57:23 AMACANC
PLEASE CALL HOMEOWNER NATALIE/CLINT @ # LISTED WHEN EN ROUTE. PREFERS AFTER 9 A.M. Phone #: ###-#### >> Inspection requested via web by SOPHIA FLEMING Inspection cancelled from web by: SOPHIA FLEMING