MEC19-05281
| Final | 11/25/2019 | 11/25/2019 | 11/25/2019 3:33:36 PM | P | PASS |
|
|
Please call Paul prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- electric furnace coil only ok
|
MEC19-05339
| Final | 11/25/2019 | 11/25/2019 | 11/25/2019 3:11:03 PM | P | NH |
|
|
BJ ###-####. Home is open, workers present floor is opened up in the laundry room Inspection requested via web by william kerwin- no one onsite- house locked up
|
MEC19-05317
| Final | 11/22/2019 | 11/25/2019 | 11/25/2019 2:43:46 PM | P | PASS |
|
|
Same day Install. Will not be ready for inspection until the afternoon. Please call Michael, technician on site, to ensure job is ready. If you run into any issues, call Alyssa at ###-####. Contact Name: Michael Contact Phone:###-#### Phone #: ###-#### Inspection requested via web by Alyssa Cromwell- furnace only co ok
|
MEC19-05263
| Pressure Test | 11/25/2019 | 11/25/2019 | 11/25/2019 2:19:49 PM | P | PASS |
|
|
Tim Phone #: ###-####- 20lb gas pass- will need access door installed in ceiling by final to access main gas shutoff valve- all 4 shutoff valves will need sediment traps installed after shut offs and before appliances- equipment may need tethers by final also
|
MEC19-05146
| Rough-in | 11/25/2019 | 11/25/2019 | 11/25/2019 2:00:59 PM | P | FAIL |
|
|
Approved Man J is now on site Phone #: ###-#### Inspection requested via web by Randy Hart- b vent appears to have screw thru it- verify and replace if needed thru roof- need to seal all spotwelds on supply and return air boots some are missing seal
|
MEC19-05325
| Rough-in | 11/24/2019 | 11/25/2019 | 11/25/2019 1:25:08 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- R/I ok
|
MEC19-05325
| Pressure Test | 11/24/2019 | 11/25/2019 | 11/25/2019 1:24:04 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- 20lb gas pass ragged meter location
|
MEC19-05326
| Rough-in | 11/24/2019 | 11/25/2019 | 11/25/2019 12:50:56 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE 1- all rips and tears in arma flex need repaired in wall and attic 2- b vent thru garage wall needs insulation shield 3- need to support range duct in attic 4- dryer duct needs nail plates at ceiling 5- condensate drain does not have grade to washer box is trapped in attic
left notice
|
MEC19-05326
| Pressure Test | 11/24/2019 | 11/25/2019 | 11/25/2019 12:48:19 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- 20lb gas pass tagged meter location
|
MEC19-04464
| Final | 11/24/2019 | 11/25/2019 | 11/25/2019 12:28:56 PM | P | PASS |
|
|
Garage code is 2468 Phone #: ###-#### Inspection requested via web by JOSE DUARTE
|
MEC19-05085
| Final | 11/22/2019 | 11/25/2019 | 11/25/2019 11:32:42 AM | A | PASS |
|
|
This is a Flue Pressure and Final Inspect. Please meet our installer at home at 11:30. Contact for Right Now is Mary ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace only co ok- 5lb flue pass
|
MEC19-05224
| Final | 11/19/2019 | 11/25/2019 | 11/25/2019 11:00:24 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette- electric furnacer coil heat pump co locking caps ok
|
MEC19-05146
| Rough-in | 11/22/2019 | 11/25/2019 | 11/25/2019 10:36:59 AM | A | FAIL |
|
|
Reinspect Phone #: ###-#### Inspection requested via web by Randy Hart- need city approved man j onsite- need to seal all spotwelds on register boots
|
MEC19-05146
| Pressure Test | 11/22/2019 | 11/25/2019 | 11/25/2019 10:36:13 AM | A | PASS |
|
|
Reinspect Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass tagghed meter location- 5lb flue pass
|
MEC19-05315
| Pressure Test | 11/22/2019 | 11/25/2019 | 11/25/2019 10:15:21 AM | A | NH |
|
|
Pressure test and fireplace. Call prior to arrival. Phone #: ###-#### Inspection requested via web by Jamee Shoecraft- no one available for inspection per phone call- I rescheduled for tomorrow am per phone call
|
MEC19-02561
| Rough-in | 11/22/2019 | 11/25/2019 | 11/25/2019 10:05:50 AM | A | PART |
|
|
Roger Graves is the job site contact ###-#### Phone #: ###-#### Inspection requested via web by Doug Madsen- seal on all ducting ok- need to finish insulation on all ducting above hard lids- all register cans need installed in bathrooms and flex for hard lid cover- call in R/I inspection when these are completed- need engineer approval on galv duct for class 2 hood shows to run in aluminum
|
MEC19-05049
| Final | 11/22/2019 | 11/25/2019 | 11/25/2019 9:44:16 AM | A | FAIL |
|
|
CALL WHEN ON THE WAY Phone #: ###-#### Inspection requested via web by Ashley Shoecraft- need flue supported on roof
|
MEC19-04381
| Final | 11/21/2019 | 11/25/2019 | 11/25/2019 9:16:42 AM | A | FAIL |
|
|
Please have inspector call Joe when in route to his home. ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd- need to schedule flue test for witness- service ports on a/c needs locking caps
|
MEC19-05319
| Final | 11/22/2019 | 11/25/2019 | 11/25/2019 9:02:31 AM | A | PASS |
|
|
Call 30 minutes prior to arriving for inspection so I can make sure to be there to open door. Phone #: ###-#### Inspection requested via web by marco gomez- furnace gas piping co ok
|
MEC19-05319
| Pressure Test | 11/25/2019 | 11/25/2019 | 11/25/2019 9:02:02 AM | A | PASS |
|
|
Call 30 minutes prior to arriving for inspection so I can make sure to be there to open door. Phone #: ###-#### Inspection requested via web by marco gomez- 20lb gas pass tagged meter location
|
MEC19-04335
| Rough-in | 11/25/2019 | 11/25/2019 | 11/25/2019 8:47:35 AM | A | PASS |
|
|
2 fire smoke damper clearances ok-
|
MEC19-05113
| Rough-in | 11/21/2019 | 11/25/2019 | 11/25/2019 8:46:44 AM | A | PASS |
|
|
Secondary light test of grease duct after installation on jobsite. Phone #: ###-#### Inspection requested via web by Stephen Lee- light test pass ok for firewrap
|
MEC19-01834
| Mec-Aging Inspection | 11/25/2019 | 11/25/2019 | 11/25/2019 8:11:36 AM | | FAIL |
|
|
needs called in for final inspection- permit will expire next aging if no activity
|