MEC18-05156
| Pressure Test | 11/5/2018 | 11/6/2018 | 11/6/2018 2:05:33 PM | P | PASS |
|
|
Please have inspector call the installer Matt when in route to home for gas pressure test ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd- 20lb gas pass whole existing system- tagged gas piping at meter bar location-
|
MEC18-05279
| Final | 11/6/2018 | 11/6/2018 | 11/6/2018 1:41:17 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace only co ok
|
MEC18-04831
| Rough-in | 11/6/2018 | 11/6/2018 | 11/6/2018 1:14:51 PM | P | FAIL |
|
|
Dorthy Phone #: ###-####- range hood ducting correction not made (IRC 1503.1)- remove crimped oval 90 degree and smashed 6" 90 degree and reroute both units- reinspection fee issued
|
MEC18-04831
| Pressure Test | 11/6/2018 | 11/6/2018 | 11/6/2018 1:14:03 PM | P | CANC |
|
|
Dorthy Phone #: ###-####- already passed
|
MEC18-04832
| Rough-in | 11/6/2018 | 11/6/2018 | 11/6/2018 1:10:00 PM | P | PASS |
|
|
Dorthy Phone #: ###-####- R/I ok- corrections made
|
MEC18-05284
| Rough-in | 11/5/2018 | 11/6/2018 | 11/6/2018 11:23:34 AM | A | PART |
|
|
Hard Lid for Faith Christian Center - Please call Mike Dominguez with any questions ###-#### Phone #: ###-#### Inspection requested via web by Heather Gransbery- seal and insulation on ducts in hard lid areas only ok for cover
|
MEC18-04557
| Final | 11/5/2018 | 11/6/2018 | 11/6/2018 10:38:33 AM | A | PART |
|
|
Mechanical Final needed for Lifetime AM preferred if you have any questions contact Karl at ###-#### Phone #: ###-#### Inspection requested via web by Karl Hestekin- need air balance report on EF 2 part of CO detection system- grid ceiling registers and flex all good- ok to cover- need relief damper completed and operational- need RTU 1E condensate drain installed- temp occupancy
|
MEC18-05298
| Pressure Test | 11/5/2018 | 11/6/2018 | 11/6/2018 10:01:03 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette- 20lb gas pass from meter to furnace location- need to straighten gas piping in closet- need to seal outdoors gas piping penetration and make sure has inert tape on it- will need combustion air in closet and b vent will need a insulation shield in attic
|
MEC18-05255
| Final | 11/6/2018 | 11/6/2018 | 11/6/2018 9:16:10 AM | A | CANC |
|
|
please call so we can meet you there for the pressure test Phone #: ###-#### Inspection requested via web by Marisa Hone
|
MEC18-05255
| Pressure Test | 11/6/2018 | 11/6/2018 | 11/6/2018 9:16:01 AM | A | FAIL |
|
|
please call so we can meet you there for the pressure test Phone #: ###-#### Inspection requested via web by Marisa Hone- flue wont hold pressure- recall in when fixed and schedule time with me to meet
|
MEC17-05104
| Mec-Aging Inspection | 11/6/2018 | 11/6/2018 | 11/6/2018 8:27:53 AM | | FAIL |
|
|
still need contractor to schedule inspection
|
MEC18-03097
| Pressure Test | 11/5/2018 | 11/6/2018 | 11/6/2018 8:27:17 AM | A | PART |
|
|
60lb pressure test gauge on roof- ###-####- 60lb gas test from roof to mech room- need to retest whole system once gas has extended to meter after core drill is done
|
MEC18-05312
| Pressure Test | 11/5/2018 | 11/6/2018 | 11/6/2018 7:42:11 AM | P | CANC |
|
|
Please call Chuck prior to arrival ###-#### >> Inspection requested via web by Arielle Hendricks Inspection cancelled from web by: Arielle Hendricks
|
MEC18-03097
| Conference | 11/5/2018 | 11/6/2018 | 11/5/2018 12:59:13 PM | A | CANC |
|
|
pressure test- 208- ###-####- scheduled for conference not pressure test
|