MEC19-05542
| Final | 12/9/2019 | 12/12/2019 | 12/12/2019 12:53:02 PM | P | PASS |
|
|
Joyce would like after 12pm. If possible call prior to arrival. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace a/c coil co locking caps ok
|
MEC19-05456
| Pressure Test | 12/10/2019 | 12/12/2019 | 12/12/2019 11:21:11 AM | A | PASS |
|
|
Field super: Chad Robertson is requesting a LATE AM apt. please Phone #: ###-#### Inspection requested via web by Lisa Whitney- 60lb gas pass X 2 tagged meter location- 20lb gas pass to range
|
MEC19-05438
| Final | 12/11/2019 | 12/12/2019 | 12/12/2019 10:59:39 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace coil gas piping duct in crawl co ok- primary drain open end must be higher than secondary drain add 6" to it- send pic for reinspect
|
MEC19-05563
| Pressure Test | 12/11/2019 | 12/12/2019 | 12/12/2019 10:41:58 AM | A | PASS |
|
|
Request mid to late morning gas line and flue pressure tests. Can call ahead to Chase (QHC) @ ###-#### or Kevin (QHC) @ Phone #: ###-#### Inspection requested via web by Kevin Pratley- 20lb gas pass tagged meter location- 5lb flue pass
|
MEC19-05579
| Final | 12/10/2019 | 12/12/2019 | 12/12/2019 9:59:22 AM | A | PASS |
|
|
please call homeowner Cheryl when 30 mins in route Phone #: ###-#### Inspection requested via web by Rick Montgomery- furnace a/c coil co locking caps ok
|
MEC19-05489
| Pressure Test | 12/11/2019 | 12/12/2019 | 12/12/2019 9:26:16 AM | A | PASS |
|
|
60lb test on gas supply piping to aud. Gas reg installed inside of building in attic on west side of Aud. Phone #: ###-#### Inspection requested via web by Dave Sorensen- 60lb gas pass from meter underground to regulator in building attic- tagged this gas line at meter- ok to cover
|
MEC19-05489
| Rough-in | 12/12/2019 | 12/12/2019 | 12/12/2019 9:25:07 AM | A | PASS |
|
|
60lb test on gas supply piping to aud. Gas reg installed inside of building in attic on west side of Aud. Phone #: ###-#### Inspection requested via web by Dave Sorensen- R/I ok- regulator installed in attic
|
MEC19-05420
| Final | 12/6/2019 | 12/12/2019 | 12/12/2019 8:58:29 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Denise Colin
|
MEC19-05420
| Pressure Test | 12/6/2019 | 12/12/2019 | 12/12/2019 8:58:16 AM | A | NH |
|
|
Phone #: ###-#### Inspection requested via web by Denise Colin- met installer onsite- no one home knocked and rang doorbell- reschedule when homeowners available
|
MEC19-05578
| Final | 12/11/2019 | 12/12/2019 | 12/12/2019 8:33:08 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace only co ok
|