Inspections for the day of: Wednesday, December 18, 2019.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-04381 Final12/17/201912/18/201912/18/2019 3:49:11 PMPPASS
Please call Install Aaron when in route to home ###-#### also Home owner Joe ###-####. Joe the home owner will be home at 2:30pm this is for the flue test. Phone #: ###-#### Inspection requested via web by Carolyn Rudd- furnace a/c coil co locking caps ok- 5lb flue pass
MEC19-05580 Final12/18/201912/18/201912/18/2019 3:04:26 PMPPASS
El-Ada #A-12954 Karen Andree Phone #: ###-#### Inspection requested via web by Loren Bailey
MEC19-05607 Final12/12/201912/18/201912/18/2019 2:24:30 PMPNR
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- still installing- recall in when ready
MEC19-05531 Rough-in12/18/201912/18/201912/18/2019 1:57:54 PMPFAIL
Phone #: ###-#### Inspection requested via web by Nicolas Barajas- need to resubmit man j- equipment oriented different than man j- R/A ducting for second floor different than whats installed- shows ducted R/A in master has transfer- missing 14" round R/A second floor now is side wall off furnace or install per approved man j
2-need to seal dryer duct to termination box in wall
3-exhaust fan second floor needs finished
4- crawl needs completed on R/I inspection

left notice on window
MEC19-05531 Pressure Test12/18/201912/18/201912/18/2019 1:54:19 PMPPASS
Gas to Furnace, WH and range Phone #: ###-#### Inspection requested via web by Nicolas Barajas- 20lb gas pass tagged meter location- 5lb flue pass
MEC19-05316 Final12/16/201912/18/201912/18/2019 1:21:51 PMPPASS
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 1:00 PM . Contact for Right Now is Mary ###-####

Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace coil co ok- 5lb flue pass
MEC19-05190 Final12/18/201912/18/201912/18/2019 12:32:45 PMPPASS
Please call me at ###-#### 30 minutes prior to arrival to insure i''m on site. Inspection requested via web by Terry Warden- 5lb flue pass
MEC19-05618 Final12/16/201912/18/201912/18/2019 11:13:03 AMAFAIL
tenants phone number is ###-#### - she will be home in the AM but is hoping for late morning - please call her when you are on the way Phone #: ###-#### Inspection requested via web by Amanda Casper- furnace ok- need to provide 2 co detectors near bedrooms none found- send pic for reinspect
MEC19-03009 Final12/17/201912/18/201912/18/2019 10:47:27 AMAPASS
AC: 3162 Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok
MEC19-04195 Final12/13/201912/18/201912/18/2019 10:16:50 AMAFAIL
Please call Ann Shaffer prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- need locking caps on a/c service ports- send pic for reinspect
MEC19-05616 Rough-in12/17/201912/18/201912/18/2019 10:03:34 AMAPART
Mechanical Gas Fireplace Rough-In Inspection Phone #: ###-#### Inspection requested via web by Dan Otero- fireplace R/Iok will pass when gas line by different contractor is issued and inspected- do not cover- talked with homeowner onsite
MEC19-05655 Rough-in12/17/201912/18/201912/18/2019 9:42:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Shaun Bevan- R/I ok on range duct bathex and dryer exhaust- call in final when range hood installed
MEC19-03009 Final12/17/201912/18/201912/17/2019 1:38:12 PMACANC
AC: 3162 Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves