Inspections for the day of: Friday, December 21, 2018.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-05331 Final12/20/201812/21/201812/21/2018 3:54:17 PMPPASS
PATRICIA ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
MEC18-05331 Rough-in12/20/201812/21/201812/21/2018 3:51:14 PMPPASS
PATRICIA ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza-R/I ok
MEC18-04136 Final12/21/201812/21/201812/21/2018 3:32:39 PMPPASS
Jake is your contact Phone #: ###-#### Inspection requested via web by Kim Adams- final ok- card signed
MEC18-06071 Pressure Test12/21/201812/21/201812/21/2018 3:08:48 PMPPASS
LOUI ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- 20lb gas pass whole sysyem- tagged gas piping at meter location
MEC18-05268 Final12/21/201812/21/201812/21/2018 2:39:33 PMPPASS
Enter back yard from gate on left side of garage. Gas line starts at gas meter and runs to outside of the garage. Capped off at meter, and shut off and cap at garage. Phone #: ###-#### Inspection requested via web by Jason Adams
MEC18-05547 Final12/20/201812/21/201812/21/2018 2:26:35 PMPFAIL
Please call client prior to arrival at ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- need to fix all rips and tears in arma flex whole lineset- insulation used is only 4.2 equivelent needs to be R-6 on supply and return- need 3/4" air gap to get to R-6 per manufactures installation instructions
MEC18-06062 Final12/21/201812/21/201812/21/2018 2:14:25 PMPPASS
20lb gas pass to range from meter- co ok
MEC18-06071 Final12/21/201812/21/201812/21/2018 1:31:32 PMPCANC
LOUI ###-#### Phone #: ###-#### >> Inspection requested via web by Arielle Hendricks Inspection cancelled from web by: Arielle Hendricks
MEC18-06062 Pressure Test12/21/201812/21/201812/21/2018 1:26:13 PMPNH
Phone #: ###-#### Inspection requested via web by Justin Osterhout- no one answered to doorbell or knock on door
MEC18-06075 Final12/21/201812/21/201812/21/2018 12:58:27 PMPNH
Please contact Matthew McCafferty for site access or any questions at ###-####. Phone #: ###-#### Inspection requested via web by Joshua Bennett- called # listed twice no answer- texted # listed per voicemail no return text- reschedule when someones available
MEC18-05722 Final12/19/201812/21/201812/21/2018 11:22:05 AMAPASS
home owner will be home after 10;00 Phone #: ###-#### Inspection requested via web by Kim Lithander- furnace a/c coil co ok
MEC18-06070 Final12/21/201812/21/201812/21/2018 10:55:59 AMAPASS
LATE AM / BRACK ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- final ok
MEC18-04970 Final12/20/201812/21/201812/21/2018 9:35:17 AMAPASS
Request for re inspection on Final. Partial pass 12/17. Please contact Chris ###-#### Inspection requested via web by Heather Gransbery- final ok- card signed
MEC18-04843 Final12/20/201812/21/201812/21/2018 9:06:51 AMAFAIL
code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- need uv protection on lineset at a/c- need to seal gas line where penetrates building has a hole
MEC18-03097 Final12/20/201812/21/201812/21/2018 8:27:18 AMAPASS
BRAD IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- final ok
MEC17-04543 Mec-Aging Inspection12/21/201812/21/201812/21/2018 8:10:33 AM FAIL
contractor needs to schedule inspection
MEC18-05980 Final12/14/201812/21/201812/18/2018 7:32:18 AMACANC
Please call Renee at ###-#### when in route Phone #: ###-#### >> Inspection requested via web by Sabrina DeHority Inspection cancelled from web by: Sabrina DeHority