MEC18-05432
| Final | 12/5/2018 | 12/7/2018 | 12/7/2018 4:09:22 PM | P | PASS |
|
|
Call Jeff in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace a/c coil co ok
|
MEC18-04873
| Final | 12/6/2018 | 12/7/2018 | 12/7/2018 3:39:15 PM | P | PASS |
|
|
Daniel ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c coil range hood co ok
|
MEC18-04871
| Final | 12/6/2018 | 12/7/2018 | 12/7/2018 3:37:08 PM | P | PASS |
|
|
Daniel ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c coil range hood co ok
|
MEC18-05868
| Final | 12/6/2018 | 12/7/2018 | 12/7/2018 3:18:40 PM | P | PASS |
|
|
Inspection requested via web by Margie Rowe- electric furnace heat pump ok
|
MIS18-00453
| MEC-Conference | 12/7/2018 | 12/7/2018 | 12/7/2018 3:02:37 PM | P | PASS |
|
|
MEC work being done without permits. call Matt W if questions- HVAC permits were already issued
|
MIS18-00454
| MEC-Conference | 12/7/2018 | 12/7/2018 | 12/7/2018 3:02:10 PM | P | PASS |
|
|
MEC work being done without permits. call Matt W if questions- HVAC permits were already issued
|
MEC18-05778
| Final | 12/5/2018 | 12/7/2018 | 12/7/2018 2:56:47 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette= furnace co ok
|
MEC18-05856
| Rough-in | 12/6/2018 | 12/7/2018 | 12/7/2018 2:28:09 PM | P | FAIL |
|
|
PLEASE CALL HOMEOWNER TIM WHEN 30-45 MINS IN ROUTE SO HE CAN MEET YOU THERE. THANKS SO MUCH AND HAPPY FRIDAY! Phone #: ###-#### Inspection requested via web by Rick Montgomery- need approved manual J onsite- need to seal all boots to floor with mastic- need to run combustion air from furnace thru roof garage is to small- toe kicks need to be all ducted no wood can be exposed on floor and wood framed in around pipe on floor- register in bath room not completed
|
MEC18-05865
| Final | 12/6/2018 | 12/7/2018 | 12/7/2018 1:38:43 PM | P | PASS |
|
|
Craig ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace a/c coil co ok
|
MEC18-05017
| Final | 12/3/2018 | 12/7/2018 | 12/7/2018 1:16:13 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft- fireplace final ok
|
MEC18-01304
| Final | 12/7/2018 | 12/7/2018 | 12/7/2018 12:28:22 PM | P | PASS |
|
|
furnace a/c coil co ok- 5lb flue test pass
|
MEC18-04700
| Final | 12/6/2018 | 12/7/2018 | 12/7/2018 10:51:09 AM | P | PASS |
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- final ok
|
MEC18-05608
| Rough-in | 12/6/2018 | 12/7/2018 | 12/7/2018 10:26:23 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace 2nd floor doesnt match man j model number need to resubmit with equipment installed or install right furnace- dryer vent exceeds 35 feet max length need to reroute 2nd floor- all registers need sealed on inside supply and r/a cans- 6" fresh air cant come from roof 2nd floor- bath #3 needs moved to location on man j theres a slider door being installed-condensate need ran not sure whats going on with them 2nd floor- range duct in garage is below joists- all ducts need sealed in basement registers and square duct all floors lots partially done- need 6" fresh air to downstairs furnace- need condesate ran to outide downstairs not sure where it will be going no floor sink to drain to, needs to be ran in 3/4 pvc- correction notice left front window
|
MEC18-05608
| Pressure Test | 12/6/2018 | 12/7/2018 | 12/7/2018 10:19:01 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Aaron Alandt- 20lb gas pass- 5lb flue for downstair furnace and upstairs water heater pass
|
MEC18-05809
| Final | 12/4/2018 | 12/7/2018 | 12/7/2018 9:06:06 AM | A | PART |
|
|
can you please call when you are on the way Phone #: ###-#### Inspection requested via web by Marisa Hone- furnace a/c coil co ok- need to pull plumbing permit for water heater to final out this permit- water heater has a minimal leak homeowner seen this on expansion tank
|
MEC17-05535
| Mec-Aging Inspection | 12/7/2018 | 12/7/2018 | 12/7/2018 8:15:42 AM | | CANC |
|
|
correction need completed and recalled in for final inspection by contractor
|
MEC17-04379
| Mec-Aging Inspection | 12/7/2018 | 12/7/2018 | 12/7/2018 8:14:56 AM | | FAIL |
|
|
need final inspection called in by contractor
|