Inspections for the day of: Friday, December 7, 2018.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-05432 Final12/5/201812/7/201812/7/2018 4:09:22 PMPPASS
Call Jeff in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace a/c coil co ok
MEC18-04873 Final12/6/201812/7/201812/7/2018 3:39:15 PMPPASS
Daniel ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c coil range hood co ok
MEC18-04871 Final12/6/201812/7/201812/7/2018 3:37:08 PMPPASS
Daniel ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c coil range hood co ok
MEC18-05868 Final12/6/201812/7/201812/7/2018 3:18:40 PMPPASS
Inspection requested via web by Margie Rowe- electric furnace heat pump ok
MIS18-00453 MEC-Conference12/7/201812/7/201812/7/2018 3:02:37 PMPPASS
MEC work being done without permits. call Matt W if questions- HVAC permits were already issued
MIS18-00454 MEC-Conference12/7/201812/7/201812/7/2018 3:02:10 PMPPASS
MEC work being done without permits. call Matt W if questions- HVAC permits were already issued
MEC18-05778 Final12/5/201812/7/201812/7/2018 2:56:47 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette= furnace co ok
MEC18-05856 Rough-in12/6/201812/7/201812/7/2018 2:28:09 PMPFAIL
PLEASE CALL HOMEOWNER TIM WHEN 30-45 MINS IN ROUTE SO HE CAN MEET YOU THERE. THANKS SO MUCH AND HAPPY FRIDAY! Phone #: ###-#### Inspection requested via web by Rick Montgomery- need approved manual J onsite- need to seal all boots to floor with mastic- need to run combustion air from furnace thru roof garage is to small- toe kicks need to be all ducted no wood can be exposed on floor and wood framed in around pipe on floor- register in bath room not completed
MEC18-05865 Final12/6/201812/7/201812/7/2018 1:38:43 PMPPASS
Craig ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace a/c coil co ok
MEC18-05017 Final12/3/201812/7/201812/7/2018 1:16:13 PMPPASS
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft- fireplace final ok
MEC18-01304 Final12/7/201812/7/201812/7/2018 12:28:22 PMPPASS
furnace a/c coil co ok- 5lb flue test pass
MEC18-04700 Final12/6/201812/7/201812/7/2018 10:51:09 AMPPASS
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- final ok
MEC18-05608 Rough-in12/6/201812/7/201812/7/2018 10:26:23 AMAFAIL
Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace 2nd floor doesnt match man j model number need to resubmit with equipment installed or install right furnace- dryer vent exceeds 35 feet max length need to reroute 2nd floor- all registers need sealed on inside supply and r/a cans- 6" fresh air cant come from roof 2nd floor- bath #3 needs moved to location on man j theres a slider door being installed-condensate need ran not sure whats going on with them 2nd floor- range duct in garage is below joists- all ducts need sealed in basement registers and square duct all floors lots partially done- need 6" fresh air to downstairs furnace- need condesate ran to outide downstairs not sure where it will be going no floor sink to drain to, needs to be ran in 3/4 pvc- correction notice left front window
MEC18-05608 Pressure Test12/6/201812/7/201812/7/2018 10:19:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Aaron Alandt- 20lb gas pass- 5lb flue for downstair furnace and upstairs water heater pass
MEC18-05809 Final12/4/201812/7/201812/7/2018 9:06:06 AMAPART
can you please call when you are on the way Phone #: ###-#### Inspection requested via web by Marisa Hone- furnace a/c coil co ok- need to pull plumbing permit for water heater to final out this permit- water heater has a minimal leak homeowner seen this on expansion tank
MEC17-05535 Mec-Aging Inspection12/7/201812/7/201812/7/2018 8:15:42 AM CANC
correction need completed and recalled in for final inspection by contractor
MEC17-04379 Mec-Aging Inspection12/7/201812/7/201812/7/2018 8:14:56 AM FAIL
need final inspection called in by contractor