Inspections for the day of: Thursday, February 21, 2019.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-02982 Final2/20/20192/21/20192/21/2019 4:07:18 PMPPASS
Inspection requested via web by Marisa Hone- furnace a.c coil co ok
MEC19-00752 Final2/20/20192/21/20192/21/2019 3:14:24 PMPPASS
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok
MEC19-00730 Final2/19/20192/21/20192/21/2019 2:27:04 PMPPASS
Client will be available between 10 AM and 3PM.
Thank you
Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace only co ok
MEC19-00596 Final2/20/20192/21/20192/21/2019 1:34:07 PMPPASS
after 100pm- ###-####- Britt- furnace coil only co ok
MEC19-00746 Final2/20/20192/21/20192/21/2019 11:28:07 AMAPASS
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek- furnace only co ok
MEC19-00746 Pressure Test2/20/20192/21/20192/21/2019 11:26:04 AMAPASS
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek- 5lb flue test pass
MEC18-05917 Rough-in2/20/20192/21/20192/21/2019 11:14:06 AMAPART
sealing and fire damper framing Phone #: ###-#### Inspection requested via web by Nicholas Paige- area 2 C/D need some framing on 3 dampers addressed- rest are good- recall in when seal and framing completed
MEC19-00173 Final2/20/20192/21/20192/21/2019 10:16:05 AMAPASS
Installed range hood, Ran gas from cabinet stub out to gas cook top. Hooked range hood duct up. Sealed joints. If there are any questions please call Gary. Thank you. Phone #: ###-#### Inspection requested via web by Gary Duncan- final ok
MEC18-03194 Rough-in2/20/20192/21/20192/21/2019 9:38:35 AMAPASS
Rough-in on first-floor eastside. Please call Patrick prior to arrival at ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Maira Napoles- R/I ok 1st floor- pipe insulation needs to be plenum rated
MEC18-03194 Pressure Test2/21/20192/21/20192/21/2019 9:37:22 AMAPASS
Rough-in on first-floor eastside. Please call Patrick prior to arrival at ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Maira Napoles- 1st floor only 100# test on hydronics pass- ok for insulation
MEC18-04954 Final2/20/20192/21/20192/21/2019 9:09:02 AMAFAIL
Inspection requested via web by Marisa Hone- needs to schedule a flue test to be witnessed- single wall flue from water heater needs 6" clearance to pvc flue on furnace- need to pull water heater permit for new water heater thats installed- furnace a/c coil co ok
MEC19-00466 Final2/20/20192/21/20192/21/2019 8:32:22 AMAPASS
IF THERE IS ANY ISSUES PLEASE LET US KNOW. MY NAME IS STEVE WITH DIAMOND HEATING. Phone #: ###-#### Inspection requested via web by Rick Montgomery- final ok