Inspections for the day of: Tuesday, February 26, 2019.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-05537 Final2/25/20192/26/20192/26/2019 3:59:11 PMPPASS
Please call when you are on your way Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace only co ok
MEC19-00355 Final2/26/20192/26/20192/26/2019 3:40:23 PMPPASS
pls advise of eta Phone #: ###-#### Inspection requested via web by Dave Sorensen- final ok- card signed
MEC18-04900 Final2/22/20192/26/20192/26/2019 2:59:15 PMPPASS
Please call when you are on your way ###-#### or ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace only co ok
MEC19-00806 Final2/26/20192/26/20192/26/2019 2:28:43 PMPPASS
Contact John for access: ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello- furnace a/c coil co ok
MEC18-03530 Final2/20/20192/26/20192/26/2019 2:08:16 PMPPASS
Mark ###-#### if needed Inspection requested via web by Marisa Hone- furnace a/c coil co ok
MEC19-00733 Rough-in2/25/20192/26/20192/26/2019 1:40:14 PMPFAIL
re inspection code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- all corrections not made- need to insulate wye branch front entry door bare metal showing- water heater b vent needs 1" clearance to plywood where b vent goes thru 1st floor ceiling in chase from garage- correction notice still posted front entry window
MEC19-00733 Pressure Test2/25/20192/26/20192/26/2019 1:36:41 PMPPASS
re inspection code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass- tagged meter location-
MEC19-00758 Final2/21/20192/26/20192/26/2019 1:05:34 PMPFAIL
Please call Ann Peck about 30-60 minutes prior to inspection so she can get home from work to meet you. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace co ok- need 1" clearance to b vent at ceiling and trim ring installed and firecaulked
MEC19-00784 Final2/21/20192/26/20192/26/2019 11:07:09 AMAPASS
if possible can you please come as close to 11 as possible Thanks! Phone #: ###-#### Inspection requested via web by Marisa Hone- furnace a/c coil co ok
MEC19-00576 Rough-in2/25/20192/26/20192/26/2019 10:00:19 AMAPASS
Phone #: ###-#### Inspection requested via web by Debbie Marino- R/I ok- fireplace R/I ok
MEC19-00576 Rough-in2/26/20192/26/20192/26/2019 9:59:50 AMAPASS
Phone #: ###-#### Inspection requested via web by Debbie Marino- fireplace R/I ok
MEC19-00576 Pressure Test2/25/20192/26/20192/26/2019 9:59:27 AMAPASS
Phone #: ###-#### Inspection requested via web by Debbie Marino- 20lb gas pass- tagged meter location
MEC19-00577 Rough-in2/25/20192/26/20192/26/2019 9:59:01 AMAFAIL
Phone #: ###-#### Inspection requested via web by Debbie Marino- need framing completed around b vent and R/A ducting in closet- rest is good
MEC19-00577 Pressure Test2/25/20192/26/20192/26/2019 9:58:13 AMAPASS
Phone #: ###-#### Inspection requested via web by Debbie Marino- 20lb gas pass- tagged meter location
MEC18-05917 Rough-in2/25/20192/26/20192/26/2019 8:57:53 AMAPART
sealing and fire damper framing Phone #: ###-#### Inspection requested via web by Nicholas Paige- seal on duct area 2C only ok to insulate- fire damper framing area 2C only ok
MEC19-00595 Pressure Test2/25/20192/26/20192/26/2019 8:31:15 AMACANC
Presssure test on the new gas line that was moved to the inside of the house.
Also inspection on the relocation and main vent pipe for the furnace and water heater.
Please call so I can get you access to the house, not sure if anyone will be there.
Please try to make it for mid to late morning. Phone #: ###-#### Inspection requested via web by Geff Blecha- can not do inspection til bld permit has been issued- mech permit needs attached to bld permit when issued