Inspections for the day of: Wednesday, February 26, 2020.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS20-00066 MEC-Conference2/26/20202/26/20202/27/2020 11:04:11 AMPNH
Kitchen Creations - CDHD called to say that they are using a residential hood for an industrial oven, not adequate for the steam and grease produced. Phone #: ###-####- went by no one on premise- all locked up- left notice back door with business card- schedule inspection for monday to swing by and see if anyone here
MEC20-00798 Final2/25/20202/26/20202/26/2020 3:38:07 PMPPASS
Please have inspector call Jenni when in route to home ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd- furnace only co ok
MIS20-00065 MEC-Conference2/26/20202/26/20202/26/2020 3:11:10 PMPDONE
talked with people onsite- they stated permits will be issued- any mechanical work being done requires a permit I.E. new furnace a/c ducting exhaust fans etc and inspected- left notice front door-
MEC20-00052 Final2/26/20202/26/20202/26/2020 2:52:45 PMPPASS
Front door is open Phone #: ###-#### Inspection requested via web by JOSE DUARTE- final ok
MEC20-00592 Final2/26/20202/26/20202/26/2020 2:31:49 PMPCANC
Phone #: ###-#### Inspection requested via web by Sarah Small- should have been R/I inspection
MEC20-00592 Rough-in2/26/20202/26/20202/26/2020 2:30:40 PMPFAIL
Phone #: ###-#### Inspection requested via web by Sarah Small
1- poly vinyl tubing not approved material needs ran in 3/4 inch pvc close to head on center block wall and graded 1/4inch per foot in attic to exterior
2- b vent needs 1" clearance to combustibles at roof and insulation shield installed
3- need open tee between 2 shutoff valves on gas line for pressure test/ retest gas line when fixed

correction notice post in window
MEC19-04221 Final2/26/20202/26/20202/26/2020 1:53:25 PMPPASS
garage 4646 Phone #: ###-#### Inspection requested via web by Debbie Marino- HVAC and fireplace final ok
MEC20-00810 Final2/26/20202/26/20202/26/2020 1:12:07 PMPPASS
you can call Ben to schedule inspection time. Phone #: ###-#### Inspection requested via web by max sanders- furnace in crawl co ok- 5lb flue pass
MEC19-01679 Final2/25/20202/26/20202/26/2020 12:00:44 PMAPART
Phone #: ###-#### Inspection requested via web by Amanda Farnsworth- temp occupancy ok-
1- need uv protection on mini split arma flex and seal penetration thru roof weather tight
2- need air balance report sent to me
3- need all equipment set and opertrational under class 1 and 2 hoods
4- RFI on smoke dectectors for RTU 25 a and b and 26 a and b still needs addressed and approved

call in final when ready
MEC20-00803 Final2/25/20202/26/20202/26/2020 11:10:45 AMAPASS
Please call home owner Doug Johnson ###-#### 30 minutes prior to inspection. Phone #: ###-#### Inspection requested via web by Teresa Costello- 20lb gas pass
MEC19-05649 Final2/24/20202/26/20202/26/2020 10:34:51 AMAFAIL
Call Tony in route to ###-####--water heater scheduled same day Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace a/c coil co ok- need locking caps on a/c service ports- send pic for reinspect
PLM20-00783 Water Heater Final2/24/20202/26/20202/26/2020 10:33:57 AMAPASS
Mechanical scheduled same day Phone #: ###-#### Inspection requested via web by Justin Osterhout- water heater co ok
MEC20-00691 Rough-in2/25/20202/26/20202/26/2020 10:23:02 AMAPASS
manj will be on site at furnace location information bin. Phone #: ###-#### Inspection requested via web by Oleg -R/I ok
MEC20-00703 Final2/21/20202/26/20202/26/2020 10:11:20 AMAFAIL
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 10 AM. Contact for Right Now is Mary ###-####

Phone #: ###-#### Inspection requested via web by Mary LaFayette
1- flue not holding pressure
2- need intake to furnace ran to roof can not communication with bathroom
3- condensate pump is blocking filter access need to make sure filter is removeable

call in for reinspect and flue test when ready
PLM20-00684 Final2/25/20202/26/20202/26/2020 9:54:02 AMAPASS
need to txt homeowner when you get to house ; he will let you in, his office is in the basement ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- water heater co ok
MEC20-00704 Final2/25/20202/26/20202/26/2020 9:53:43 AMAPASS
need to txt Pat when you get to his house as his office is in the basement
###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok- 5lb flue pass
MEC19-03528 Mec-Aging Inspection2/26/20202/26/20202/26/2020 7:46:45 AM FAIL
contractor needs to schedule inspection- permit has not been active since it was issued- permit will expire next aging if no activity
MEC19-01662 Mec-Aging Inspection2/26/20202/26/20202/26/2020 7:45:19 AM CANC
needs final called- WIP
MEC19-02010 Mec-Aging Inspection2/26/20202/26/20202/26/2020 7:44:26 AM CANC
permit expired
MEC19-02010 DOC - Permit Expired2/26/20202/26/20202/26/2020 7:44:10 AMAPASS
no calls no activity- permit expired
MEC20-00540 Final2/26/20202/26/20202/26/2020 7:40:17 AMAPASS
final ok