Inspections for the day of: Wednesday, February 6, 2019.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-00527 Pressure Test2/6/20192/6/20192/6/2019 3:54:26 PMPPASS
Thomas Phone #: ###-####- 20lb gas pass from meter to furnace location- tagged meter location
MEC18-05844 Rough-in2/6/20192/6/20192/6/2019 3:20:47 PMPCANC
Mike Phone #: ###-####- per phone call with mike- will reschedule
MEC18-05921 Final2/6/20192/6/20192/6/2019 2:39:27 PMPFAIL
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- equipment installed does not match manual j- need to resubmit to city and have approved manual j onsite for final inspection
MEC18-05922 Final2/6/20192/6/20192/6/2019 2:38:17 PMPFAIL
Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- equipment installed does not match manual j- need to resubmit to city and have approved manual j onsite for final inspection
MEC19-00502 Final2/6/20192/6/20192/6/2019 2:36:44 PMPPASS
furnace only co ok
MEC18-04793 Final2/6/20192/6/20192/6/2019 1:59:33 PMPNH
final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- no access
MEC18-02215 Conference2/6/20192/6/20192/6/2019 1:30:09 PMPDONE
Need a conference for Magnificent Garden by phone today at 1:00pm if possible can contact Karl at ###-#### thank you Phone #: ###-#### Inspection requested via web by Karl Hestekin- looked at existing hoods in kitchen where walls and ceiling were replaced- wasnt on prints of any work done to kitchen area- clearance to combustibles might not be met- all labeling is gone or not ledgeable- will meet tomorrow with chad and karl at 930ish
MEC19-00019 Rough-in2/5/20192/6/20192/6/2019 11:41:30 AMAFAIL
code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- fireplace flue draft stop needs minimum 1" clearance to combustibles at attic location- all exhaust fans needs sealed plastic to metal fittings(still ongoing issue)- gas line in attic needs supported /secured to structure every 10 feet to fireplace- left correction notice front entry window- furnace and coil match manual j in attic
MEC19-00019 Pressure Test2/5/20192/6/20192/6/2019 11:36:00 AMAPASS
code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass- tagged meter location
MEC19-00515 Rough-in2/5/20192/6/20192/6/2019 11:21:38 AMAFAIL
code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- all exhaust fans need sealed from plastic to metal fitting(still ongoing issue)- lineset in attic needs supported every 6 feet- need to insulate fresh air can where ties onto R/A plenum in attic bare metal- left correction notice front window- furnace and coil match man j in attic
MEC19-00515 Pressure Test2/5/20192/6/20192/6/2019 11:13:05 AMAPASS
code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass- tagged meter location
MEC19-00481 Final2/1/20192/6/20192/6/2019 10:18:28 AMAPASS
Please call Don at ###-#### when in route Phone #: ###-#### Inspection requested via web by Sabrina DeHority- RTU final ok
MEC19-00503 Final2/5/20192/6/20192/6/2019 9:37:14 AMAPASS
Phone #: ###-#### Inspection requested via web by Scott Wickstrom- furnace only co ok
MEC19-00460 Final1/31/20192/6/20192/6/2019 8:36:14 AMACANC
If you could call the homeowner when you''re on your way that would be greatly appreciated. Thank you Phone #: ###-#### Inspection requested via web by Kim Evans- per phone call with homeowner ionstall has not been done yet- installing next week- reschedule when install is complete