Inspections for the day of: Friday, March 15, 2019.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-00912 Final3/14/20193/15/20193/15/2019 3:48:17 PMPPASS
Please call Brandon in route to inspection ###-####-- Plumbing inspection scheduled for same time frame Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace a/c coil co ok
MEC18-03021 Final3/11/20193/15/20193/15/2019 3:19:04 PMPPASS
Please call homeowner when you are on your way Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace a/c coil co ok
MEC19-01006 Final3/15/20193/15/20193/15/2019 2:51:40 PMPPASS
Phone #: ###-#### Inspection requested via web by Kim Evans- furnace only co ok
MEC19-01040 Final3/14/20193/15/20193/15/2019 2:25:52 PMAPASS
Phone #: ###-#### Inspection requested via web by Nicholas Paige- need electrical inspection ok"d to final out- All looks good on our side- clearance is more than 36" with panning on inside of paint booth- electrical permit has been finaled-
MEC19-00989 Rough-in3/15/20193/15/20193/15/2019 2:21:12 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak- need flue under test/gas test fail under 20psi- need to insulate supply and R/A ducts in joist above furnace- need to seal inside all boots 2nd floor supply and return- fireplace installation instructions need to easily accessed its behind glass- insulation on wye branch 2nd floor at stairs needs vapor barrier on it exposed insulation- need to secure b vent for water heater in chase and attic 2nd floor-need to seal dryer duct where enters termination box- left correction notice front entry window
MEC19-00989 Pressure Test3/15/20193/15/20193/15/2019 2:16:25 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak- need flue under test/ gas test failed gauge below 20psi
MEC19-01019 Final3/15/20193/15/20193/15/2019 1:36:29 PMPPASS
Josh A-i perfect 130-145pm- furnace a/c coil co ok- installed new flue with insulation shield
MEC19-01026 Final3/14/20193/15/20193/15/2019 1:18:08 PMPPASS
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok
MEC19-00762 Pressure Test3/14/20193/15/20193/15/2019 11:34:05 AMAFAIL
Phone #: ###-#### Inspection requested via web by Debbie Marino- gauge below 5 psi on gas gauge
MEC19-00762 Rough-in3/14/20193/15/20193/15/2019 11:33:07 AMAFAIL
Phone #: ###-#### Inspection requested via web by Debbie Marino- fireplace installation instructions need to be readily accessible they are behind glass- ALL arma flex needs all rips and tears fixed inside wall and attic bare copper showing and supported every 4 feet- gas test fail gauge below 5psi- 2 wire on lineset in attic to close to b vent- need to secure/support b vent in attic- left correction notice front entry window
MEC19-00991 Pressure Test3/13/20193/15/20193/15/2019 10:38:17 AMAPASS
Call Kris (homeowner) prior to arrival Phone #: ###-#### Inspection requested via web by Jamee Shoecraft- 20lb gas pass- will final out this permit when log set permit is issued
MEC19-01037 Rough-in3/15/20193/15/20193/15/2019 10:30:57 AMAPART
Mechanical Final Inspection needed for Friday Am if possible if you have any questions contact Karl at ###-#### Phone #: ###-#### Inspection requested via web by Karl Hestekin- cassette ok- misc ducting ok- all exposed ducting except bathrooms- need to seal duct outside before completing insulation- insulation outside needs to be R-12 per IECC 2015
MEC19-01037 Final3/14/20193/15/20193/15/2019 10:26:27 AMACANC
Mechanical Final Inspection needed for Friday Am if possible if you have any questions contact Karl at ###-#### Phone #: ###-#### Inspection requested via web by Karl Hestekin- i changed to R/I inspection
MEC19-01017 Pressure Test3/14/20193/15/20193/15/2019 9:36:35 AMPCANC
Please call technician on site for flue test Bill ###-#### Phone #: ###-#### >> Inspection requested via web by Justin Osterhout Inspection cancelled from web by: Justin Osterhout
MEC19-00597 Conference3/11/20193/15/20193/15/2019 9:26:58 AMACANC
Phone #: ###-#### Inspection requested via web by Elizabeth Gawle- need installation instruction for range hood onsite- none could be found- recall in inspection when onsite
MEC19-01019 Final3/13/20193/15/20193/15/2019 9:01:24 AMAFAIL
Please contact client for inspection if going to be late. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- need to remove single adjustable 90 degree and replace with b vent 90- can not go from single wall to b vent then to single wall flue again- recall in when correction made
MEC19-00935 Final3/12/20193/15/20193/15/2019 8:47:09 AMAFAIL
Please contact client (Jordan) prior to arrival at ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace a/c coil co ok- need to add otherto permit and pay fee for new duct work in crawl thats been replaced and all bare metal supply plenum and wye branches need to be insulate to R-6- recall in inspection when completed- need to seal lineset penetration outside at a/c location
MEC19-01038 Final3/14/20193/15/20193/15/2019 8:32:16 AMAPART
Call ahead // Virginia ###-####- furnace only co ok- need to pull permit for tankless water heater installed and the this permit will final out
MEC18-02914 Mec-Aging Inspection3/15/20193/15/20193/15/2019 8:21:55 AM CANC
homeowner will need to request extension if no inspections are done by next aging- permit will expire on 7-20-19