MEC19-01031
| Final | 3/19/2019 | 3/22/2019 | 3/22/2019 4:07:35 PM | P | PASS |
|
|
PLEASE CALL HOMEOWNER BILL WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery- furnace a/c coil co ok
|
MEC19-01003
| Rough-in | 3/22/2019 | 3/22/2019 | 3/22/2019 3:38:40 PM | P | PASS |
|
|
Daniel 20-###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- R/I ok- missing a few seal on supply boots 2nd floor Bill GC knows- just have sealed by final
|
MEC19-01152
| Final | 3/21/2019 | 3/22/2019 | 3/22/2019 2:27:07 PM | P | PASS |
|
|
Please call John to ensure install is complete. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg- a/c coil only co ok
|
MEC19-00963
| Rough-in | 3/21/2019 | 3/22/2019 | 3/22/2019 2:00:33 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- need stamped approved manual j onsite for inspection
|
MEC19-00963
| Pressure Test | 3/21/2019 | 3/22/2019 | 3/22/2019 1:59:49 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass- tagged meter location- 5lb flue pass
|
MEC19-01163
| Final | 3/21/2019 | 3/22/2019 | 3/22/2019 1:47:33 PM | P | NH |
|
|
Inspection requested via web by Margie Rowe
|
MEC19-01107
| Final | 3/22/2019 | 3/22/2019 | 3/22/2019 1:15:04 PM | P | PASS |
|
|
Mechanical Final inspection needed for today contact Mike with any questions at ###-#### Code for door 9701 Phone #: ###-#### Inspection requested via web by Karl Hestekin- final ok- card signed
|
MEC19-01133
| Rough-in | 3/21/2019 | 3/22/2019 | 3/22/2019 11:16:45 AM | P | PART |
|
|
Permit had been issued but in Review status for Plan mod, adding kitchen appliances- please call Permit desk for any questions. Please call Adam for access Phone #: ###-####- R/I will pass when gas test passes- R/A and supply drops both units need flex connectors installed per general note 13-
|
MEC19-01133
| Pressure Test | 3/21/2019 | 3/22/2019 | 3/22/2019 11:14:59 AM | A | FAIL |
|
|
Permit had been issued but in Review status for Plan mod, adding kitchen appliances- please call Permit desk for any questions. Please call Adam for access Phone #: ###-####- gauge at 18 psi
|
MEC19-01051
| Rough-in | 3/21/2019 | 3/22/2019 | 3/22/2019 10:55:53 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley- need city approved and stamped manual J onsite- outside air can not tie into R/A can needs tied into plenum- contractor needs to provide ladder to access furnace and coil in attic- left notice front window
|
MEC19-01051
| Pressure Test | 3/21/2019 | 3/22/2019 | 3/22/2019 10:53:51 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Terek Worley- 20lb gas pass- tagged meter location
|
MEC18-02562
| Final | 3/15/2019 | 3/22/2019 | 3/22/2019 10:23:57 AM | A | PASS |
|
|
If possible, Please call home owner one hour before at ###-####- a/c coil co ok
|
MEC18-04424
| Final | 3/21/2019 | 3/22/2019 | 3/22/2019 9:57:47 AM | A | PASS |
|
|
Patrick Phone #: ###-####- furnace a/c coil co ok
|
MEC18-05684
| Final | 3/21/2019 | 3/22/2019 | 3/22/2019 9:41:23 AM | A | NH |
|
|
No response to phone calls and certified letter. Please attempt inspection. Phone #: ###-#### Inspection requested via web by Mary LaFayette- no one home- left notice
|
MEC19-01122
| Final | 3/19/2019 | 3/22/2019 | 3/22/2019 9:27:14 AM | A | FAIL |
|
|
Any time, morning or afternoon, should be fine. Thank you! Phone #: ###-#### Inspection requested via web by kelly Martin- need to seal off gas line penetration at meter weather/rodent proof- b vent needs 1" clearance to combustibles ie insulation, wiring and at roof- sheet rock needs installed where b vent is and an insulation shield installed- need to provide co detectors by bedrooms
|
MEC19-01088
| Final | 3/21/2019 | 3/22/2019 | 3/22/2019 9:08:57 AM | A | PASS |
|
|
This is a Flue Pressure and Final Inspect. Please meet our installer at home at 9:00 AM. Contact for Right Now is Mary ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok- 5lb flue pass
|
MEC19-01001
| Rough-in | 3/20/2019 | 3/22/2019 | 3/22/2019 8:53:36 AM | A | PASS |
|
|
GAS INSERT INTO MASONRY FIREPLACE. GAS WAS ALREADY EXISTING.
HOMEOWNER RON ; MARY 208.570.3702 Inspection requested via web by Mike Almanza- R/I ok- gas shut off needs to be accessable and csst piping sleeved by final
|
MEC18-03005
| Mec-Aging Inspection | 3/22/2019 | 3/22/2019 | 3/22/2019 8:06:27 AM | | FAIL |
|
|
contractor needs to schedule inspection- if no activity by next aging permit will expire
|
MEC18-03051
| Mec-Aging Inspection | 3/22/2019 | 3/22/2019 | 3/22/2019 8:05:42 AM | | FAIL |
|
|
contractor needs to schedule inspection- if no activity by next aging cycle permit will be expired
|
MEC18-03107
| Mec-Aging Inspection | 3/22/2019 | 3/22/2019 | 3/22/2019 8:04:49 AM | | FAIL |
|
|
need inspection called in by contractor- permit will expire next aging cycle if no activity
|
MEC18-04424
| Final | 3/21/2019 | 3/22/2019 | 3/21/2019 2:53:56 PM | A | PASS |
|
|
No response to phone calls or certified letter. Please go by and attempt inspection. Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
|