Inspections for the day of: Tuesday, March 3, 2020.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-00910 Final3/3/20203/3/20203/3/2020 3:41:11 PMPPASS
###-#### Call Willie prior to arrival to ensure ready for inspection. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace a/c coil co locking caps ok
MEC20-00910 Pressure Test3/3/20203/3/20203/3/2020 3:38:13 PMPPASS
Please call Willie prior to arrival to ensure ready and on pressure.
###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- 5lb flue pass
MIS20-00051 MEC-Conference3/3/20203/3/20203/3/2020 3:02:56 PMPPASS
Mechanical permit has been issued- there are 2 parcel at this address and mec20-00818 is pulled for mech work at 12248 Goldenrod- mis20-00051 has different partial than mech permit
MEC19-05489 Final3/2/20203/3/20203/3/2020 2:59:25 PMPPASS
Phone #: ###-#### Inspection requested via web by Dave Sorensen- final ok
MEC10-02322 Final3/3/20203/3/20203/3/2020 2:15:11 PMPFAIL
Steve Phone #: ###-####- fireplace surrounds on both fireplaces do not meet clearance to combustibles- this millwork will need to meet installation instructions minimum clearances- homeowner will figure something out and call for a conference before proceeding- 3 bath fans, dryer duct and range ok
MEC20-00785 Final2/26/20203/3/20203/3/2020 1:18:05 PMPPASS
Please call Tom Butler prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co locking caps ok
PLM20-00788 Water Heater Final2/26/20203/3/20203/3/2020 1:17:40 PMPPASS
Please call Tom Butler prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- water heater co ok
MEC20-00899 Final3/2/20203/3/20203/3/2020 12:41:09 PMPNH
GUNNER ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza
MEC20-00899 Rough-in3/2/20203/3/20203/3/2020 12:40:55 PMPNH
GUNNER ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- no one home- left notice- reschedule when someone available
MEC19-02519 Final3/3/20203/3/20203/3/2020 12:03:40 PMAPART
Francisco is the contact. Phone #: ###-#### Inspection requested via web by stan lillquist- need approved weather tight connectors on mc cable atmini split condenser- Francisco will get right parts and send pic for final inspection
MEC20-00896 Pressure Test3/3/20203/3/20203/3/2020 10:12:14 AMPCANC
Please do as soon as possible. Our installers will be there for a little while. Gauge in garage. Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette
MEC20-00837 Final2/28/20203/3/20203/3/2020 9:47:10 AMAPASS
Nancy Nelson is primary contact, please call prior to arrival. ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace only co ok
MEC20-00764 Rough-in3/2/20203/3/20203/3/2020 9:11:31 AMAPASS
re inspection Phone #: ###-#### Inspection requested via web by Randy Hart- R/I ok
MEC20-00695 Pressure Test2/28/20203/3/20203/3/2020 8:34:56 AMAFAIL
call Diane ###-#### before arrival- 815-830am- gas line needs to be tested to 20lb on 30lb psi gauge max- if live test with gas on one side of valve will need open tee and another shutoff valve installed or section test csst before hooking onto live gas system- do not use gas as installed now- shut off valve is closed at furnace location til pressure test witnessed- went over onsite with homeowner- will reschedule
MEC19-02519 Mec-Aging Inspection3/3/20203/3/20203/3/2020 8:05:48 AM CANC
doing inspection today around 10 with Francisco