Inspections for the day of: Friday, March 6, 2020.
Number of inspections: 28
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-00880 Final3/3/20203/6/20203/6/2020 3:48:13 PMPPASS
Field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney- furnace a/c coil co locking caps ok
MEC19-04637 Rough-in3/5/20203/6/20203/6/2020 3:25:03 PMPNR
Kirk Phone #: ###-####- rescheduled for monday am
MEC20-00156 Final3/5/20203/6/20203/6/2020 3:00:03 PMPPASS
AFTERNOON INSPECTION REQUESTED. PLEASE CALL CUSTOMER BEFORE HEADING OUT AT ###-#### Phone #: ###-#### Inspection requested via web by Trina DeBoard- fireplace final co ok
MEC20-00927 Rough-in3/6/20203/6/20203/6/2020 2:36:12 PMPPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- R/I ok
MEC20-00927 Pressure Test3/6/20203/6/20203/6/2020 2:35:38 PMPPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- 20lb gas pass tagged meter location- 5lb flue pass
MEC20-00942 Final3/5/20203/6/20203/6/2020 1:55:47 PMPPASS
Please call Craig at the above number 1/2 hr before your arrival so he can meet you there. Thank you Phone #: ###-#### Inspection requested via web by Lynn Johnston
MEC19-05298 Rough-in3/6/20203/6/20203/6/2020 1:54:49 PMPCANC
JOB CONTACT - ROSS ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- should have been pressure test
MEC19-05298 Pressure Test3/6/20203/6/20203/6/2020 1:39:05 PMPPART
JOB CONTACT - ROSS ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- 60lb gas pass from meter thru roof-ok to cover gas piping in wall only- will retest whole system once installed-
MEC20-00876 Final3/4/20203/6/20203/6/2020 1:05:24 PMPFAIL
El-Ada #A-12972; Claudia Cocini Phone #: ###-#### Inspection requested via web by Loren Bailey- furnace a/c coil co ok- need to seal exterior linset penetration outside at condenser weather tight- need to witness flue test in conditioned space
MEC20-00895 Final3/3/20203/6/20203/6/2020 12:32:24 PMPPASS
Please call Dan Benjamin about 30 minutes prior to inspection so he can get home. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnaxce only co ok
MEC20-00839 Rough-in3/5/20203/6/20203/6/2020 11:17:25 AMAFAIL
Access lock box on gas meter 1027 Phone #: ###-#### Inspection requested via web by David Nelson
1- exhaust fan and outside air needs ran per approved drawings see key note 4 and 9 on ME-2 for details/ need to coordinate with GC on 1 hour shaft thats required for med gas room per A2.1 symbol 5 and have a conference with building inspector on this onsite

left notice on door
MEC20-00758 Rough-in3/6/20203/6/20203/6/2020 10:33:02 AMAPASS
Inspection requested via web by Rubin Chervak- R/I ok
MEC20-00703 Final3/6/20203/6/20203/6/2020 9:51:26 AMACANC
flue test at 10 am- per mary will reschedule homeowner not available
MEC20-00904 Rough-in3/5/20203/6/20203/6/2020 9:37:29 AMAFAIL
You will need to access the property through a lock box the code is 4888 Phone #: ###-#### Inspection requested via web by Sarah Small
1- flue test failed and gauge needs to max 15 lb gauge
2- missing transfer grill 1st floor bedroom 3
3- crawl needs completed on R/I inspection
4- toe kicks need ducted out to register can not communicate with cabinet
5- 2 bath fans first floor needs metal to plastic sealed at fan locations

left notice front window
MEC20-00904 Pressure Test3/5/20203/6/20203/6/2020 9:35:27 AMAFAIL
we need a flue inspection test for a high efficiency furnace install
also gas pressure test on gas line
You will access the property with lock box the code is 4888 Phone #: ###-#### Inspection requested via web by Sarah Small- 20lb gas pass tagged meter location- 5lb flue at zero and needs tested on max 15lb gauge
MEC19-05298 Rough-in3/5/20203/6/20203/6/2020 8:52:53 AMAFAIL
JOB CONTACT - ROSS ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- gauge doesnt zero out replace and retest
MEC20-00703 Final3/6/20203/6/20203/6/2020 8:24:54 AMPCANC
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 10. Contact for Right Now is Mary ###-####

Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC20-00703 Final3/6/20203/6/20203/6/2020 8:24:44 AMACANC
flue test at 10am
MEC19-05378 Final3/5/20203/6/20203/6/2020 8:24:11 AMAPASS
Ac 3162 Phone #: ###-#### Inspection requested via web by Gary Reeves
MEC19-05381 Final3/5/20203/6/20203/6/2020 8:23:39 AMAPASS
ac 3162 Phone #: ###-#### Inspection requested via web by Gary Reeves
MEC20-00857 Final3/3/20203/6/20203/6/2020 8:11:25 AMACANC
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 10:00 AM . Contact for Right Now is Mary ###-####

Phone #: ###-#### Inspection requested via web by Mary LaFayette- scheduled wrong address
MEC20-00894 Final3/3/20203/6/20203/6/2020 7:54:48 AMPCANC
Homeowner Michael Desseyn ###-#### Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette
MEC20-00796 Final3/3/20203/6/20203/6/2020 7:54:37 AMACANC
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 9:00 AM . Contact for Right Now is Mary ###-####

Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette
MEC19-03677 Mec-Aging Inspection3/6/20203/6/20203/6/2020 7:41:50 AM FAIL
needs called in for final inspection when ready- bld still open
MEC19-02150 Mec-Aging Inspection3/6/20203/6/20203/6/2020 7:40:52 AM CANC
permit expired
MEC19-02150 DOC - Permit Expired3/6/20203/6/20203/6/2020 7:40:40 AMAPASS
no calls no activity- permit expired
MEC19-03673 Mec-Aging Inspection3/6/20203/6/20203/6/2020 7:39:43 AM FAIL
contractor needs to schedule inspection has not been active since permit issued- permit will expire next aging if no activity
MEC19-05146 Final3/5/20203/6/20203/5/2020 9:50:19 AMACANC
Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart