Inspections for the day of: Wednesday, April 10, 2019.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-01434 Final4/9/20194/10/20194/10/2019 4:03:22 PMPPASS
Phone #: ###-#### Inspection requested via web by Steve Torgerson- final ok- card signed- exposed duct off existing RTU
MEC19-00744 Final4/3/20194/10/20194/10/2019 3:14:02 PMPCANC
Please call Sharon when in route to home ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd- i rescheduled this inspection for 4-16-19 in am per phone call with homeowner she wasnt available til then
MEC19-01437 Final4/10/20194/10/20194/10/2019 2:00:48 PMPFAIL
There should be a key in the mail box to the right of the door for entry. There is alot of activity out there today. Entry should be available. Call Todd @ ###-#### for help getting in if that doesn''t work. Phone #: ###-#### Inspection requested via web by Angie Maguire- need draft stop and insulation shield install in chase with 1" clearance at ceiling- insulation and electrical wiring dont have clearance to b vent
MEC19-01399 Final4/8/20194/10/20194/10/2019 1:42:35 PMPPASS
Field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney- furnace a/c coil co ok- 5lb flue test pass
MEC19-01223 Rough-in4/9/20194/10/20194/10/2019 11:34:23 AMANR
Phone #: ###-#### Inspection requested via web by Arielle Hendricks- need 2nd floor framing completed and registers installed- missing fire caulk couple places 2nd floor exhaust at wall penetration- 3rd floor register cans need sealed west unit- 1st floor east unit needs duct in crawl supported- talked onsite with Dan about these issues
MEC19-01400 Rough-in4/9/20194/10/20194/10/2019 10:54:34 AMAPASS
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft- fireplace R/I ok
MEC19-01425 Final4/9/20194/10/20194/10/2019 10:46:31 AMAPART
Mechanical Final needed for Am MOD Pizza please contact Karl at ###-#### thanks. Phone #: ###-#### Inspection requested via web by Karl Hestekin- plumbing vents need top be 10 feet away or 3 feet above RTU intakes
MEC19-01406 Final4/9/20194/10/20194/10/2019 10:08:40 AMAPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
MEC19-01210 Rough-in4/9/20194/10/20194/10/2019 8:10:52 AMAPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok
MEC18-03760 Mec-Aging Inspection4/10/20194/10/20194/10/2019 7:58:39 AM CANC
needs called in for inspection by contractor