Inspections for the day of: Wednesday, April 17, 2019.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-01348 Final4/17/20194/17/20194/17/2019 3:42:00 PMPPASS
ROOF TAP 2EA CALL FOR EXS Phone #: ###-#### Inspection requested via web by Oleg Chervak- 2 RTUs ok
MEC19-01529 Final4/16/20194/17/20194/17/2019 3:21:24 PMPPASS
Field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney- a/c coil ok
MEC19-01464 Final4/15/20194/17/20194/17/2019 2:39:54 PMPFAIL
Homeowner Brian Arehart ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- a/c coil co 2 supply duct ok- need right size breaker for a/c unit breaker to big
MEC19-01501 Final4/15/20194/17/20194/17/2019 2:18:31 PMPPASS
INSTALLER TRAVIS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 2 furnaces 2 a/c's 2 coils ok
MEC19-01548 Final4/17/20194/17/20194/17/2019 1:48:06 PMPPASS
Phone #: ###-#### Inspection requested via web by Marisa Hone- a/c coil co ok
MEC19-01378 Rough-in4/17/20194/17/20194/17/2019 1:17:13 PMPNR
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- still installing
MEC19-01378 Pressure Test4/17/20194/17/20194/17/2019 1:15:43 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass- tagged meter location- 5lb flue pass
MEC19-01523 Final4/16/20194/17/20194/17/2019 11:30:02 AMAPASS
Call ahead to Callie at ###-#### when in route Phone #: ###-#### Inspection requested via web by Sabrina DeHority- furnace only co ok
MEC19-01536 Rough-in4/16/20194/17/20194/17/2019 11:01:33 AMAFAIL
Thanks, Brian ###-#### Phone #: ###-#### Inspection requested via web by Andrea Creek- R/A insulation in attic needs to be R-6 and remove batting insulation installed on one side and and wrap with vapor barrier insulation- need stamped and approved manual j onsite- transfers in bedroom dont match man j sizing and might interfere with doors- dryer vent needs ran in 5.5 inch wall not 3.5 inch wall need to fir out- talked with general contractor onsite- left correction notice front window
MEC19-01536 Pressure Test4/16/20194/17/20194/17/2019 10:57:49 AMAFAIL
Thanks, Brian ###-#### Phone #: ###-#### Inspection requested via web by Andrea Creek- 60lb gas test failed below 60psi- 20lb gas pass- 5lb flue test pass
MEC19-01522 Final4/16/20194/17/20194/17/2019 9:27:07 AMAPASS
Phone #: ###-#### Inspection requested via web by Marisa Hone- furnace a/c coil co ok
MEC19-01433 Final4/15/20194/17/20194/17/2019 8:55:33 AMAPASS
Phone #: ###-#### Inspection requested via web by Marisa Hone- furnace only co ok
MEC18-03969 Mec-Aging Inspection4/17/20194/17/20194/17/2019 8:15:58 AM FAIL
contractor needs to schedule inspection with homeowner- permit will expire 7-17-19 if no activity
MEC18-03974 Mec-Aging Inspection4/17/20194/17/20194/17/2019 8:15:00 AM FAIL
contractor needs to schedule inspection with homeowner- permit will expire 7-17-19 if no activity
MEC18-03995 Mec-Aging Inspection4/17/20194/17/20194/17/2019 8:13:44 AM FAIL
contractor needs to schedule inspection if work was done- permit will expire 7-17-19 if no activity
MEC18-03999 Mec-Aging Inspection4/17/20194/17/20194/17/2019 8:12:33 AM FAIL
Contractor needs to schedule inspection if work was done- permit will expire 7-17-19 in no activity