MEC19-01319
| Final | 4/12/2019 | 4/18/2019 | 4/18/2019 4:10:00 PM | P | FAIL |
|
|
Please call Janet or Michael in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- pvc furnace flue needs 6" clearance to single water heater flue- furnace a/c coil co ok
|
MEC19-00429
| Final | 4/18/2019 | 4/18/2019 | 4/18/2019 3:26:02 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek- final ok
|
MEC19-00975
| Final | 4/18/2019 | 4/18/2019 | 4/18/2019 3:05:52 PM | P | PASS |
|
|
I well send you pictures. Phone #: ###-#### Inspection requested via web by Eric Sonner- final ok
|
MEC19-01564
| Rough-in | 4/17/2019 | 4/18/2019 | 4/18/2019 2:40:09 PM | P | PASS |
|
|
Inspection requested via web by Don Dowers- R/I ok
|
MEC19-01378
| Rough-in | 4/17/2019 | 4/18/2019 | 4/18/2019 2:03:20 PM | P | FAIL |
|
|
mec and firepl Phone #: ###-#### Inspection requested via web by Oleg Chervak- need approved manual onsite for inspection
|
MEC19-01566
| Rough-in | 4/18/2019 | 4/18/2019 | 4/18/2019 1:45:05 PM | P | FAIL |
|
|
8" hood vent. Phone #: ###-#### Inspection requested via web by Eric Sonner- all range hood over 400cfm need make up air installed- talked with general contractor onsite about options
|
MEC19-01536
| Rough-in | 4/17/2019 | 4/18/2019 | 4/18/2019 11:43:27 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Andrea Creek- R/I ok
|
MEC19-01536
| Pressure Test | 4/17/2019 | 4/18/2019 | 4/18/2019 11:43:12 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Andrea Creek- 60lb gas pass tagged meter location- 20lb gas pass- 5lb flue x 2 pass
|
MEC19-01377
| Rough-in | 4/18/2019 | 4/18/2019 | 4/18/2019 11:23:12 AM | P | CANC |
|
|
ROUGH IN. GREG IS YOUR CONTACT Phone #: ###-#### Inspection requested via web by Kim Adams- did this inspection in am today with Greg
|
MEC18-05917
| Rough-in | 4/18/2019 | 4/18/2019 | 4/18/2019 11:20:30 AM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Nicholas Paige- grease duct light test on 45 degree in ceiling 24x18 ok, 3 joints 24x18 with 20x10 and 20x10 tap ok, and 2 joints 20x10 with 90 degree ok- will see remaining weld after hood installed and welded- ok for first layer fire wrap from roof to 2nd 45 degree offset- access doors need installed
|
MEC19-01377
| Rough-in | 4/18/2019 | 4/18/2019 | 4/18/2019 10:43:09 AM | A | PART |
|
|
greg ###-####- Seal on all ducts supply and return, registers and flex ok per my initials on contractors prints
|
MEC19-01542
| Rough-in | 4/17/2019 | 4/18/2019 | 4/18/2019 9:53:35 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft- fireplace R/I on flue ok- will check fireplace clearances at final
|
MEC19-01524
| Final | 4/17/2019 | 4/18/2019 | 4/18/2019 9:24:28 AM | A | PASS |
|
|
please call when you are on the way Phone #: ###-#### Inspection requested via web by Marisa Hone- furnace a/c coil co ok
|
MEC18-05203
| Final | 4/17/2019 | 4/18/2019 | 4/18/2019 8:49:10 AM | A | FAIL |
|
|
Please call homeowner when you are on your way Phone #: ###-#### Inspection requested via web by Andrea Grigsby- needs right size fuses in disconnect at a/c location
|