MEC18-01740
| Final | 4/19/2018 | 4/19/2018 | 4/19/2018 4:04:24 PM | P | PASS |
|
|
call mark 20 min in advance to meet inspector at this house thanks Phone #: ###-#### Inspection requested via web by Manuel Canto- final ok
|
MEC18-01740
| Rough-in | 4/19/2018 | 4/19/2018 | 4/19/2018 4:04:03 PM | P | PASS |
|
|
call mark 20 min in advance to meet inspector at this house thanks Phone #: ###-#### Inspection requested via web by Manuel Canto- R/I ok- ok to cover
|
MEC18-01640
| Card not on site to sign | 4/19/2018 | 4/19/2018 | 4/19/2018 3:20:41 PM | P | PASS |
|
|
no card to sign onsite
|
MEC18-01640
| Final | 4/19/2018 | 4/19/2018 | 4/19/2018 3:19:55 PM | P | PASS |
|
|
final Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok- CO detection ok- air balance ok
|
MEC18-01743
| Pressure Test | 4/19/2018 | 4/19/2018 | 4/19/2018 2:51:10 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by PATTY KIRK- 20lb gas pass from meter to 3 locations W/H range and dryer
|
MEC17-05361
| Final | 4/19/2018 | 4/19/2018 | 4/19/2018 2:04:40 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by RaChelle Frisbee- air balance all good- CO detection system all good- general contractor has call into engineer about duct type if air balance needs to be done on this not noted so just checking- GC will call me when he gets answers- final will be granted after this conformation
|
MEC17-00986
| Conference | 4/19/2018 | 4/19/2018 | 4/19/2018 1:23:47 PM | P | DONE |
|
|
100pm- ###-####
|
MEC17-00986
| Final | 4/19/2018 | 4/19/2018 | 4/19/2018 1:23:09 PM | P | PASS |
|
|
ac coil co ok
|
MEC16-04218
| Mec-Aging Inspection | 4/19/2018 | 4/19/2018 | 4/19/2018 12:15:42 PM | | PEND |
|
|
no one home left notice front door
|
MEC14-00104
| Mec-Aging Inspection | 4/19/2018 | 4/19/2018 | 4/19/2018 11:25:49 AM | | DONE |
|
|
|
MEC14-00104
| Final | 4/19/2018 | 4/19/2018 | 4/19/2018 11:25:33 AM | A | PASS |
|
|
|
MEC18-01692
| Final | 4/18/2018 | 4/19/2018 | 4/19/2018 11:23:38 AM | A | PASS |
|
|
Please inspect after 10 AM Phone #: ###-#### Inspection requested via web by Mary LaFayette- furance coil ac co ok
|
MEC18-01692
| Pressure Test | 4/18/2018 | 4/19/2018 | 4/19/2018 11:14:54 AM | A | PASS |
|
|
Please inspect after 10 AM. Phone #: ###-#### Inspection requested via web by Mary LaFayette- 20lb gas pass to range location
|
MEC18-01100
| Final | 4/18/2018 | 4/19/2018 | 4/19/2018 10:59:26 AM | A | FAIL |
|
|
final - call David Phone #: ###-#### Inspection requested via web by Brandon Sorensen- Left correction notice on furnace 1. need drip leg between shut off valves and furnace/water heater 2.need three screws on water heater vent 3.need uv protection on line set outside 4.where line set enters indoor coil rubber groment needs placed on coil. Also need to seal coil to furnace on the front side. 5.seal hole where line set enters house and where gas line enters the house 6. seal dryer vent where it goes through the floor
|
MEC16-02807
| Mec-Aging Inspection | 4/19/2018 | 4/19/2018 | 4/19/2018 10:27:31 AM | | PEND |
|
|
homeowner would not let us in home to do inspection
|
MEC18-01707
| Rough-in | 4/18/2018 | 4/19/2018 | 4/19/2018 9:58:20 AM | A | PASS |
|
|
r/I and please inspect gas line connection // Jamie Phone #: ###-####- R/I ok- ok to cover- need siesmic bracing on both unit heaters- gas piping on both unit heaters needs drip leg between shut off valve and regulator by final
|
MEC18-00730
| Final | 4/18/2018 | 4/19/2018 | 4/19/2018 9:31:53 AM | A | PASS |
|
|
Ari Phone #: ###-####- mini split final ok- ok for cover
|
MEC18-01607
| Rough-in | 4/18/2018 | 4/19/2018 | 4/19/2018 9:03:14 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- R/I ok
|
MEC18-01607
| Pressure Test | 4/18/2018 | 4/19/2018 | 4/19/2018 9:02:46 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- 20lb gas pass
|
MEC18-00343
| Rough-in | 4/18/2018 | 4/19/2018 | 4/19/2018 8:48:52 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by dannyel chaloupka Inspection cancelled from web by: dannyel chaloupka
|
MEC18-01609
| Final | 4/17/2018 | 4/19/2018 | 4/18/2018 2:15:24 PM | P | PASS |
|
|
3-5 - Homeowner will be home around 415 and can be reached at ###-#### - If you call before 415 please call Chuck for entry at 702.862.9147 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- furnace ac coil co ok
|
MEC18-01609
| Final | 4/16/2018 | 4/19/2018 | 4/17/2018 10:00:05 AM | P | CANC |
|
|
Please call homeowner to coordinate between 3-5 - Kirk 208.859.0906 - If there are any issues call Eric @ 412.6613 Phone #: ###-#### >> Inspection requested via web by Dawn Kalsbeek Inspection cancelled from web by: Dawn Kalsbeek
|