Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-04155 Final4/16/20204/20/20204/20/2020 3:38:17 PMPFAIL
She will be home all afternoon. She will not go to the back yard this time. Phone #: ###-#### Inspection requested via web by Brian Preece- electric airhandler coil heat pump ok- needs locking caps on all heat pump service ports (3)- send pic for reinspect
MIS20-00066 MEC-Conference4/20/20204/20/20204/20/2020 3:16:02 PMPDONE
Please follow up on this when you have an extra few minutes. Thanks Chad S.- emailed AJ early in morning no response- went by and talked to guy onsite to have AJ give us an update on getting engineer- Will check next week if no response
MEC20-01515 Rough-in4/20/20204/20/20204/20/2020 3:05:09 PMPPASS
Phone #: ###-#### Inspection requested via web by Joe Taylor- R/I ok- check equipment at final not set on R/I
MEC20-01221 Rough-in4/20/20204/20/20204/20/2020 2:36:57 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak
1- gas gauge doesnt zero out- throw away
2- resubmit man j for approved equipment installed show payne with carrier installed
3- condensate drains both need 1/4" grade to outside per foot and use approved hangers drives not acceptable
4- b vent for w/h in garage will not have 1" clearance after sheetrock will be installed on ceiling and wall- need to firecaulk second floor at floor and attic in chase
5- return needs filter box installed

left notice back window
MEC20-01221 Pressure Test4/20/20204/20/20204/20/2020 2:33:22 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge doesnt xero out- throw gauge away
MEC19-05242 Final4/20/20204/20/20204/20/2020 1:45:36 PMPPART
Final inspection - Please contact Daryl prior to arrival. ###-#### Phone #: ###-#### Inspection requested via web by Commercial Coordinator- Temp occupancy ok- need to add 2 10" round dampers in OSA and Exhaust in unoccupied building and verify air balance to cfm shown on key note 2- Screening around units on roof need completed to verify access to doors are ok- talk with GC onsite
MEC20-01195 Rough-in4/17/20204/20/20204/20/2020 1:16:07 PMPFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves- crawl needs completed still installing- dryer duct can not run in 3 1/2 inch wall needs firred out or reroute
MEC20-01195 Pressure Test4/17/20204/20/20204/20/2020 1:13:56 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass tagged meter location-5lb flue
MEC20-01258 Rough-in4/20/20204/20/20204/20/2020 12:42:13 PMPPASS
duct seal inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/i ok- seal on duct ok- ok for insulation- ok for ceiling grid install- call in cover inspection when ready
MEC20-01329 Rough-in4/17/20204/20/20204/20/2020 9:56:26 AMACANC
WALL ROUGH IN. DUSTY ARMSTRONG IS THE CONTACT Phone #: ###-#### >> Inspection requested via web by RM Mechanical Inspection cancelled from web by: RM Mechanical
MEC20-00762 Final4/17/20204/20/20204/20/2020 9:38:06 AMAPASS
Duct blast report is the the back of the literature rack next to water heater and commission stick is filled out on electrical panel in garage in sharpie Phone #: ###-#### Inspection requested via web by Randy Hart- final ok
MEC20-01515 Rough-in4/16/20204/20/20204/20/2020 8:48:08 AMAFAIL
Add pressure test Phone #: ###-#### Inspection requested via web by Joe Taylor
1- need city approved man j onsite
2- dryer vent is to long with fittings installed 35 feet max including fittings
MEC20-01515 Pressure Test4/16/20204/20/20204/20/2020 8:43:55 AMAPASS
Add rough in Phone #: ###-#### Inspection requested via web by Joe Taylor- 20lb gas pass tagged meter location
MEC20-01510 Rough-in4/16/20204/20/20204/20/2020 8:43:23 AMAPASS
ROBERT ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
MEC18-04126 Mec-Aging Inspection4/20/20204/20/20204/20/2020 7:52:48 AM FAIL
contractor needs to schedule final inspection- permit has no been active since pressure test- permit will expire next aging if no activity-
MEC19-02800 Mec-Aging Inspection4/20/20204/20/20204/20/2020 7:50:21 AM CANC
permit expired
MEC19-02800 DOC - Permit Expired4/20/20204/20/20204/20/2020 7:50:09 AMAPASS
no calls no activity- permit expired
MEC19-04329 Mec-Aging Inspection4/20/20204/20/20204/20/2020 7:49:26 AM FAIL
contractor needs to schedule inspection- permit not active since issued- permit will expire next aging if no activity