MEC19-01007
| Final | 6/17/2019 | 6/17/2019 | 6/17/2019 3:48:15 PM | P | PASS |
|
|
PLEASE CALL SCOTT BANNER FOR ACCESS ###-#### AT LEAST 30 MIN PRIOR SO HE CAN MEET INSPECTOR. THANKS Phone #: ###-#### Inspection requested via web by Andrea Creek- final ok
|
MEC19-02370
| Rough-in | 6/17/2019 | 6/17/2019 | 6/17/2019 3:26:22 PM | P | NR |
|
|
John Phone #: ###-####- crawl needs completed- bedroom has supply right at entry of door instead of being under window is there a reason not where indicted on man J- need to fix all rips and tears in arma flex bare copper showing- needs register can installed for transfer in hallway to bedrooms or pan off wood with metal, wood not exceptable material for ducting
|
MEC19-02370
| Rough-in | 6/17/2019 | 6/17/2019 | 6/17/2019 3:18:25 PM | P | NR |
|
|
John- this for the fire place rough-in Phone #: ###-####- need installation insrtuction accessible behind glass- flexible flue doesnt have 1" clearance to combustibles at roof touching plywood-
|
MEC19-02370
| Pressure Test | 6/17/2019 | 6/17/2019 | 6/17/2019 3:17:07 PM | P | FAIL |
|
|
John Phone #: ###-####- gauge wont zero out
|
MEC19-02226
| Final | 6/13/2019 | 6/17/2019 | 6/17/2019 2:41:08 PM | P | PASS |
|
|
Please call Robert Gelok prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
|
MEC19-02290
| Final | 6/10/2019 | 6/17/2019 | 6/17/2019 1:39:21 PM | P | NR |
|
|
Please call Dave to ensure install is complete. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg
|
MEC19-01085
| Final | 6/17/2019 | 6/17/2019 | 6/17/2019 12:59:04 PM | P | PART |
|
|
If there are any questions please contact Ryan J. at ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann- need to reroute 2 primary coil drains so secondary drain can have wet switch installed and work with TML to see whos going to install secondary wet switch- gas piping ok-
|
MEC19-02558
| Rough-in | 6/17/2019 | 6/17/2019 | 6/17/2019 12:40:34 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kristy Watson 1- duct in crawl needs minimum 4" clearance off ground 2- b vent at roof needs 1" clearance to combustibles laying against plywood sheathing 3- need to seal all spot welds on supply and return boots 4- need to seal dryer duct to termination box in wall 5- need to resubmit man J to city for approval and have approved man j onsite with equipment brand installed- shows payne and has bryant installed
left correction notice front window
|
MEC19-02558
| Pressure Test | 6/17/2019 | 6/17/2019 | 6/17/2019 12:36:22 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kristy Watson- 20lb gas pass tagged meter location
|
MEC19-02496
| Pressure Test | 6/17/2019 | 6/17/2019 | 6/17/2019 11:32:32 AM | A | PASS |
|
|
20lb gas pass whole system- tagged meter location- 5lb flue pass
|
MEC19-02496
| Conference | 6/13/2019 | 6/17/2019 | 6/17/2019 11:28:09 AM | P | DONE |
|
|
can you call when you are on your way please. conference and pressure test. Phone #: ###-#### Inspection requested via web by Melinda Hughes 1- dryer duct needs firred out 2- support gas piping per csst gas piping installation instructions in attic 3- insulation shield needs 1" clearance to combustibles 4- b vent needs 1" clearance to combustibles floor and ceiling and b vent in furnace closet can not run over the electrical box 5- range ducting and location ? 6- combustion aior for furnace closet 1 high and 1 low 7 exhaust fans vented to outside
went over onsite with homeowner Melinda
call in R/I inspection when ready
|
MEC19-02338
| Final | 6/12/2019 | 6/17/2019 | 6/17/2019 10:36:26 AM | P | PASS |
|
|
Inspection requested via web by Margie Rowe
|
MEC18-05261
| Final | 6/14/2019 | 6/17/2019 | 6/17/2019 10:23:03 AM | A | PASS |
|
|
Please call Mark for access ###-#### Inspection requested via web by Aaron Alandt- final ok
|
MEC18-05261
| Rough-in | 6/17/2019 | 6/17/2019 | 6/17/2019 10:22:44 AM | A | PASS |
|
|
Please call Mark for access ###-#### Inspection requested via web by Aaron Alandt- R/I ok-
|
MEC18-02215
| Final | 6/14/2019 | 6/17/2019 | 6/17/2019 9:45:00 AM | A | FAIL |
|
|
Mechanical Final Inspection needed for AM Monday please contact Karl with any questions thank you. Phone #: ###-#### Inspection requested via web by Karl Hestekin- correction not made in kitchen- roof ok
|
MEC19-02463
| Final | 6/12/2019 | 6/17/2019 | 6/17/2019 8:53:18 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Devry King- furnace a/c coil co ok
|
MEC18-00547
| Mec-Aging Inspection | 6/17/2019 | 6/17/2019 | 6/17/2019 8:05:27 AM | | CANC |
|
|
contractor needs to call in inspection when ready
|
MEC18-04711
| Mec-Aging Inspection | 6/17/2019 | 6/17/2019 | 6/17/2019 8:04:48 AM | | CANC |
|
|
WIP
|