Inspections for the day of: Wednesday, June 19, 2019.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-02490 Final6/18/20196/19/20196/19/2019 3:48:30 PMPPASS
Final for ac and furnace replacement, please call Brett with any questions, ###-#### Phone #: ###-#### Inspection requested via web by Brett Shannon- furnace a/c coil co ok
MEC19-02632 Final6/19/20196/19/20196/19/2019 3:31:36 PMPPASS
Please call Jason (###-####) 30 minutes prior to showing up. Phone #: ###-#### Inspection requested via web by Michele Johnson
MEC18-05608 Final6/19/20196/19/20196/19/2019 2:58:01 PMPFAIL
Phone #: ###-#### Inspection requested via web by Aaron Alandt- need duct blast test performed on upstairs furnace- need to seal lineset penetration outside at a/c
MEC19-02633 Final6/19/20196/19/20196/19/2019 2:38:30 PMPPASS
Please call Kane (###-####) 30 minutes prior to showing up, Thank you Phone #: ###-#### Inspection requested via web by Michele Johnson- a/c coil co ok
MEC19-02567 Final6/18/20196/19/20196/19/2019 2:19:03 PMPPASS
Please call James Moison prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- a/c coil co ok
MEC18-03649 Final6/19/20196/19/20196/19/2019 2:00:25 PMPPASS
JOHN IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- final ok
MEC19-01446 Final6/19/20196/19/20196/19/2019 1:41:29 PMPCANC
Call David Lopez ###-#### prior to inspection for assistance Phone #: ###-#### Inspection requested via web by Brandon Sorensen- should have been rough in inspection
MEC19-01446 Rough-in6/19/20196/19/20196/19/2019 1:41:05 PMPPASS
Call David Lopez ###-#### prior to inspection for assistance Phone #: ###-#### Inspection requested via web by Brandon Sorensen- seal on all duct ok- ok to insulate remaining duct- need another inspection for final- leave out ceiling tiles certain areas to look at insulation- went over onsite with GC and installer- exhaust on one RTU needs to be 3 feet higher than economizer within 10 feet-
MEC19-02514 Final6/18/20196/19/20196/19/2019 1:11:40 PMPPASS
Please call Doug Link prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
MEC19-02558 Rough-in6/19/20196/19/20196/19/2019 12:49:22 PMPFAIL
Phone #: ###-#### Inspection requested via web by Kristy Watson- corrections not all made- supply duct in crawl still needs 4" clearance off ground at crawl hole location
MEC19-00677 Final6/18/20196/19/20196/19/2019 12:27:32 PMPPASS
Duct blast witness @ noon. Thanks Phone #: ###-#### Inspection requested via web by Gary Reeves- final ok- duct blast test pass
MEC19-00963 Final6/18/20196/19/20196/19/2019 12:26:59 PMPCANC
Duct blast witness @ noon. Thanks Phone #: ###-#### Inspection requested via web by Gary Reeves- need to reschedule did 2739 carmen witness
MEC19-01068 Conference6/19/20196/19/20196/19/2019 12:25:54 PMPPASS
duct blast test pass
MEC19-02278 Final6/13/20196/19/20196/19/2019 11:54:32 AMAPASS
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 11:30 AM . Contact for Right Now is Mary ###-####

Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace gas piping co ok- 5lb flue pass
MEC19-02244 Rough-in6/19/20196/19/20196/19/2019 8:14:51 AMAPART
Cover Phone #: ###-#### Inspection requested via web by Brandon Sorensen- condensste drain needs to be ran in approved material thats plenum rated for condeser pan and minisplit head drain- registers flex and insulation ok
MEC18-05333 Mec-Aging Inspection6/19/20196/19/20196/19/2019 7:48:58 AM FAIL
contractor needs to schedule inspection if work is complete- permit will expire next aging if no activity and new pemitr will need issued after expired