Inspections for the day of: Friday, June 21, 2019.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-02630 Final6/20/20196/21/20196/21/2019 2:37:16 PMPPASS
Please call Jim Peirsee prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
MEC19-02476 Pressure Test6/17/20196/21/20196/21/2019 2:07:51 PMPNR
THIS P/T IS FOR FLUE, WE ARE NOT DOING THE GAS LINE UNTIL FUTURE DATE, WILL GET GAS P/T ; FINAL AT THAT TIME Phone #: ###-#### Inspection requested via web by Aaron Alandt- flue not under pressure- schedule this when final is called in
MEC19-02648 Final6/20/20196/21/20196/21/2019 1:52:06 PMPPASS
Please inspect PM and call Jeremy on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace a/c coil co ok
MEC19-02478 Rough-in6/21/20196/21/20196/21/2019 1:21:57 PMPPASS
Pressure test/rough in for gas piping. Please call Rachael with any questions. Phone #: ###-#### Inspection requested via web by Rachael Moore- gas piping R/I ok
MEC19-02478 Pressure Test6/21/20196/21/20196/21/2019 1:15:53 PMPPASS
Pressure test/rough in inspection for pipe run. Call Rachael with any questions. Phone #: ###-#### Inspection requested via web by Rachael Moore- 20lb gas pass whole system tagged meter location-
MEC19-02479 Rough-in6/21/20196/21/20196/21/2019 1:15:24 PMPNR
Rough in inspection for 2 bath vents and 1 dryer vent. Please call Rachael with any questions. Phone #: ###-#### Inspection requested via web by Rachael Moore- insulation shields on b vent for unit heaters needs minimum 1" clearance to combustibles- need to add air conditioning to permit for mini split- went over onsite with owner- recall in inspection when ready- 2 bath fans ok- need to fir out wall and install nail plates on dryer vent at ceiling
MEC19-01377 Rough-in6/20/20196/21/20196/21/2019 11:24:37 AMAPART
Temp occupancy requested. Greg is the contact. Phone #: ###-#### Inspection requested via web by stan lillquist- needs uv protection on linset on roof and supports installed- condensers on roof need secured to roof curbs- need roofing completed on all pentrations on roof and weather tight- need to seal duct and fire caulk ceiling pentrations in furnace/water heater room northeast corners- went over with Greg onsite- signed temp occupany card
MEC19-02626 Final6/20/20196/21/20196/21/2019 10:54:24 AMAPASS
Please inspect late AM. Homeowner Helga Wilcox-Fraire ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
MEC19-02627 Final6/20/20196/21/20196/21/2019 10:30:20 AMAPASS
Homeowner Manju Ranjit ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
MEC19-02585 Rough-in6/20/20196/21/20196/21/2019 10:01:28 AMAPASS
Call Jason @ ###-#### with any inspection issues. Phone #: ###-#### Inspection requested via web by Angie Maguire- R/I ok- need to seal dryer duct to termination box by final- need to insulate supply plenum drop and any other bare metal in crawl by final- will check at final
MEC19-02661 Rough-in6/20/20196/21/20196/21/2019 9:38:37 AMAFAIL
rough in inspection for the pass through fan in the bed room. bath room fan, and transfer grills. mini split to be installed latter. Phone #: ###-#### Inspection requested via web by jeremy wanders- 3/4" condensate needs ran up to head location and remove flexable condensate in wall and maintain sloe in wall to outside of house
MEC19-02628 Final6/20/20196/21/20196/21/2019 9:22:14 AMAPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
MEC19-02244 Rough-in6/20/20196/21/20196/21/2019 8:53:19 AMAPASS
rough - call scott Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/I ok- ok for ceiling tiles excluding break room where condensate drain work will be doneneeds to be in approved metal GC is on it
MEC19-02255 Final6/20/20196/21/20196/21/2019 8:50:28 AMAPASS
final - call scott Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok
MEC18-05404 Mec-Aging Inspection6/21/20196/21/20196/21/2019 8:07:34 AM CANC
WIP- call in inspection when ready -permit will need to have extension called in by next aging permit or permit will expire
MEC18-05435 Mec-Aging Inspection6/21/20196/21/20196/21/2019 8:06:04 AM FAIL
needs called in for inspection if work was complete- permit will expire next aging and new permit will need issued if permit expires