Inspections for the day of: Thursday, June 25, 2020.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-02601 DOC - Permit Finaled6/25/20206/25/20206/25/2020 3:38:14 PMAPASS
final ok
MEC20-02601 Pressure Test6/25/20206/25/20206/25/2020 3:37:19 PMPPASS
Please call Mark at ###-#### prior to arrival if possible. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- 20lb gas pass co ok
MEC19-04127 Final6/24/20206/25/20206/25/2020 3:05:53 PMPPASS
Contact Kurtis for access ###-#### Phone #: ###-#### Inspection requested via web by John Bertram- final ok
MEC20-02510 Pressure Test6/22/20206/25/20206/25/2020 2:31:54 PMPFAIL
Phone #: ###-#### Inspection requested via web by Scott Wickstrom
1- lower pressure gas test needs max 30 lb gauge and test above 20 psi- test was at 10psi on a 60lb gauge-
2- need to install open tee between 2 gas valves in crawl 2417.1.4 2012 IRC when tying onto existing gas piping
3- provide co detector/s if none installed
retest after corrections made
MEC19-04849 Final6/25/20206/25/20206/25/2020 2:02:12 PMPPASS
Phone #: ###-#### Inspection requested via web by Kristy Watson- final ok
MEC20-02550 Final6/23/20206/25/20206/25/2020 1:39:19 PMPPASS
Homeowner Justin Lloyd ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co locking caps ok
MEC20-02556 Final6/24/20206/25/20206/25/2020 12:54:58 PMPPASS
PLEASE CALL SANDRA THE HOMEOWNER WHEN IN ROUTE- ###-#### Phone #: ###-#### Inspection requested via web by Rick Montgomery- furnace a/c coil co locking caps ok
MEC20-02590 Final6/25/20206/25/20206/25/2020 11:13:43 AMAPASS
Antonio is the contact Phone #: ###-#### Inspection requested via web by stan lillquist- final 2 bath fans ok- no card onsite to sign
MEC20-02590 Card not on site to sign6/25/20206/25/20206/25/2020 11:13:07 AMAPASS
Antonio is the contact Phone #: ###-#### Inspection requested via web by stan lillquist- card not onsite
MEC20-02590 Rough-in6/25/20206/25/20206/25/2020 11:12:39 AMAPASS
Antonio is the contact Phone #: ###-#### Inspection requested via web by stan lillquist- R/I ok 2 bath fans ok
MIS20-00071 MEC-Final6/24/20206/25/20206/25/2020 11:00:36 AMADONE
AN Phone #: ###-####- need shields installed on deep fat fryer- equipment under hood needs moved into working place with 6 inches from side of hood- grease filters need install in hood- rest is good- reschedule when ready
MEC20-01975 Final6/23/20206/25/20206/25/2020 9:43:04 AMAPASS
Please call when on the way. Thank you! Phone #: ###-#### Inspection requested via web by Denise Colin- furnace a/c coil co locking caps ok
MEC19-04849 Final6/24/20206/25/20206/25/2020 9:03:50 AMAFAIL
GARAGE CODE: 7060 Phone #: ###-#### Inspection requested via web by Kristy Watson-
1- need approved man j onsite
2- a/c needs locking caps on service ports
3- lineset needs to be off ground 3 and a half inches covered by landscaping rocks
MEC20-02315 Rough-in6/24/20206/25/20206/25/2020 8:46:03 AMAPART
duct seal inspection - cy Phone #: ###-#### Inspection requested via web by Brandon Sorensen- seal on duct ok- ok to insulate- need to call in another R/I when hood is in and ducting ran-
MEC19-05209 Mec-Aging Inspection6/25/20206/25/20206/25/2020 7:52:55 AM CANC
MEC19-05209 DOC - Permit Finaled6/25/20206/25/20206/25/2020 7:52:29 AMAPASS