Inspections for the day of: Friday, June 29, 2018.
Number of inspections: 30
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-03006 Final6/28/20186/29/20186/29/2018 3:57:14 PMPPASS
Nanci-homeower and she would like you to call her with an approx neet time Phone #: ###-####- furnace a/c coil co ok
MEC18-02992 Final6/26/20186/29/20186/29/2018 3:40:56 PMPPASS
INSTALLER JAROD ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co ok
MEC18-00951 Final6/29/20186/29/20186/29/2018 3:22:14 PMPFAIL
Phone #: ###-#### Inspection requested via web by Matthew BLANKENSHIP- need to resubmit manual J for furnace installed at residence- range hood does not meet manufactures minimum clearance for gas appiliances- need tp seal dryer duct where penetrates ion to box in laundry room
MEC18-00928 Final6/29/20186/29/20186/29/2018 2:57:00 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak- intake air for furnace not installed per manufactures recommendations for snow load/ grade above ground
MEC18-02836 Final6/29/20186/29/20186/29/2018 2:34:11 PMPPASS
Please call ###-#### prior to inspection Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co ok
MEC18-03056 Final6/28/20186/29/20186/29/2018 2:18:17 PMPNR
Late PM. Rob ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- per phone call with Rob- will reschedule
MEC18-03058 Final6/28/20186/29/20186/29/2018 1:42:38 PMPPART
Chris ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- mini split and bath exhaust ok- will final permit out when electrical permit is issued
MEC18-03048 Final6/29/20186/29/20186/29/2018 1:23:41 PMPPASS
MEC18-03048 Pressure Test6/29/20186/29/20186/29/2018 1:23:09 PMPPASS
Things should be proper this time:) Phone #: ###-#### Inspection requested via web by Nat Golden- 20lb gas pass- co ok
MEC18-00928 Final6/28/20186/29/20186/29/2018 11:27:19 AMAFAIL
LATE AM PLZ Phone #: ###-#### Inspection requested via web by Oleg Chervak- corrections still not made
MEC18-01905 Final6/28/20186/29/20186/29/2018 11:19:21 AMAFAIL
Access 3711 Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- arma flex at stucco location needs to be continous see bare copper and seal penetration- need air balance and duct blast tests completed- need drip leg on furnace and water heater between shut off valve and appliance- seal dryer vent penetration in washer closet where dryer duct comes into box
MEC18-01304 Final6/26/20186/29/20186/29/2018 10:59:01 AMAFAIL
please call when you are on the way. Customers name is Delores and her number is ###-#### Phone #: ###-#### Inspection requested via web by Marisa Hone- need to witness flue pressure test
MEC18-03049 Final6/28/20186/29/20186/29/2018 10:45:50 AMANR
Diane is homeowner, Kelly Buel is lead install for HVAC, his number is ###-#### if you have any questions. Phone #: ###-#### Inspection requested via web by kelly Martin- need to pressure test gas line and add to permit and pay fee- need combustion air in door high and low 14x8- need drip leg between shut off valve and appliance- seal linset penetration outside
MEC18-01595 Rough-in6/28/20186/29/20186/29/2018 10:22:39 AMAPART
Cover inspection. call thad prior to arriving for access Phone #: ###-#### Inspection requested via web by Nicholas Paige- north end of builing seal ok- ok to insulate- will need inspection called in when roof curbs are installed and ducts connected and to check insulation- will need to pull tiles in other phase at final to verify that flex to registers is good tile was put in without and inspection
MEC18-02976 Final6/28/20186/29/20186/29/2018 10:11:32 AMANH
Please call Steve prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- called # listed no answer- went by no one home
MEC17-05258 Final6/29/20186/29/20186/29/2018 9:49:32 AMPFAIL
Phone #: ###-#### Inspection requested via web by Sam Brown- flue on furnave need 1/4" grade to furnace has trap at wye branch- need insulation shield installed garage ceiling and maintain 1" clearance to combustibles and trim ring installed on b vent after framing is completed
MEC18-01022 Final6/29/20186/29/20186/29/2018 9:47:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Sam Brown- final ok
MEC18-00761 Final6/29/20186/29/20186/29/2018 9:47:15 AMAFAIL
Phone #: ###-#### Inspection requested via web by Sam Brown- water heater flue needs 1/4" grade has trap at wye branch- need to finish arma flex in garage bare copper exposed
MEC18-00039 Final6/29/20186/29/20186/29/2018 9:46:12 AMAPASS
Phone #: ###-#### Inspection requested via web by Sam Brown- final ok
MEC18-02917 Final6/28/20186/29/20186/29/2018 9:30:52 AMAPASS
Please give a 30 minute windows Phone #: ###-#### Inspection requested via web by Tyler Collado- furnace a/c coil co ok
MEC18-02363 Final6/22/20186/29/20186/29/2018 9:13:35 AMPCANC
Please inspect early PM if possible. Homeowner David Francke ###-#### Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette
MEC18-02999 Pressure Test6/26/20186/29/20186/29/2018 8:45:28 AMACANC
Call Jack at ###-#### to coordinate Phone #: ###-#### Inspection requested via web by Sabrina DeHority- no needed
MEC18-02999 Final6/26/20186/29/20186/29/2018 8:45:12 AMAPASS
Call Jack at ###-#### to coordinate Phone #: ###-#### Inspection requested via web by Sabrina DeHority- furnace a/c coil co ok
MEC18-02353 Rough-in6/29/20186/29/20186/29/2018 8:21:54 AMAPASS
fireplace R/I ok
MEC18-02527 Final6/29/20186/29/20186/29/2018 8:21:27 AMAPASS
MEC18-01344 Final6/28/20186/29/20186/29/2018 8:19:54 AMAPASS
#1919 Phone #: ###-#### Inspection requested via web by Ashley Stegemann- fireplace final ok
MEC16-04040 Mec-Aging Inspection6/29/20186/29/20186/29/2018 7:48:16 AM FAIL
contractor needs o fix correction and call in final inspection
MEC17-03358 Mec-Aging Inspection6/29/20186/29/20186/29/2018 7:47:25 AM FAIL
contractor needs to schedule inspection
MEC16-01175 Mec-Aging Inspection6/29/20186/29/20186/29/2018 7:46:37 AM DONE
MEC16-01175 DOC - Permit Expired6/29/20186/29/20186/29/2018 7:46:26 AMAPASS
no return call