MEC20-02032
| Rough-in | 6/29/2020 | 6/30/2020 | 6/30/2020 3:53:45 PM | P | PART |
|
|
Units 103, 203, 303, 104, 204, 304 Please call Chris on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- 103 104 203 204 R/I ok- ok to cover- 303 and 304 have issues will get with Chris tomorrow at 9
|
MEC20-02664
| Final | 6/30/2020 | 6/30/2020 | 6/30/2020 3:35:37 PM | P | PASS |
|
|
Please contact John our Install prior to arriving to verify he is ready. ###-#### Thank you! Phone #: ###-#### Inspection requested via web by Rick Borg
|
MEC20-02640
| Final | 6/29/2020 | 6/30/2020 | 6/30/2020 2:39:21 PM | P | NR |
|
|
Please inspect PM and call Chuck on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- still installing- reschedule when ready
|
MEC20-02640
| Pressure Test | 6/30/2020 | 6/30/2020 | 6/30/2020 2:36:29 PM | P | PASS |
|
|
Please inspect PM and call Chuck on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- 5lb flue pass
|
MEC20-02411
| Rough-in | 6/30/2020 | 6/30/2020 | 6/30/2020 2:15:11 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- R/I ok
|
MEC20-02529
| Rough-in | 6/29/2020 | 6/30/2020 | 6/30/2020 1:43:39 PM | P | FAIL |
|
|
manual j on site Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- missing seal on boots 3rd floor multiple locations 2- dryer duct needs notch enlarged 3- need transfers for laundry and bathroom 4- fireplace needs uncovered and instructions available 5- need to support lineset in garage joists 6- need engineers approval on gas line thru LEL beam
left notice
|
MEC20-02528
| Rough-in | 6/29/2020 | 6/30/2020 | 6/30/2020 1:41:06 PM | P | FAIL |
|
|
ready for inspection Phone #: ###-#### Inspection requested via web by Oleg Cherva 1- need access platform in attic to mini split with 30" clearance to front and unobstructe 2- fireplace needs uncovered and instructions available 3- transfer laundry and bathroom 4- range duct needs completed below framinf 5- gas gauge wont zero out 6- missing supply above stairs 3rd floor 7- need framing completed around exhaust in closet 8- condenser need drain ran for balcony can not discharge on balcony
left notice
|
MEC20-02528
| Pressure Test | 6/29/2020 | 6/30/2020 | 6/30/2020 1:37:47 PM | P | FAIL |
|
|
ready for inspection Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge wont zero out
|
MEC20-02526
| Rough-in | 6/29/2020 | 6/30/2020 | 6/30/2020 1:37:26 PM | P | FAIL |
|
|
nail plate installed manual j on site please reinspect Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- need access platform in attic to mini split with 30" clearance and unobstructed 2- dryer duct notch needs enlarged 3- will need condensate ran for condenser on balcony 4- range duct completed below framing 5- fireplace needs uncovered and instructions available 6- condensate needs ran for balcony condenser 7- transfer laundry and bathroom 8- remove undo stress on pvc drain 1st floor north bedroom wall
left notice
|
MEC20-02509
| Rough-in | 6/29/2020 | 6/30/2020 | 6/30/2020 1:34:23 PM | P | FAIL |
|
|
manual j will be on site corrections made please reinspect Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- dryer duct smashed 3rd floor notch bigger and repace duct 2- need access platform in attic to front of mini split and 30" clearance and unobstructed 3- need engineers approval for gas piping thru lel beam in garage 4- need transfers to laundry and bathroom 5- gas gauge wont zero out 6- fireplace needs uncovered and instructions available
notice left
|
MEC20-02509
| Pressure Test | 6/29/2020 | 6/30/2020 | 6/30/2020 1:31:02 PM | P | FAIL |
|
|
new gadge installed Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge doesnt zero out
|
MEC20-00098
| Final | 6/30/2020 | 6/30/2020 | 6/30/2020 12:09:18 PM | P | CANC |
|
|
Building 12 final re-inspection Phone #: ###-#### Inspection requested via web by Amanda Casper- should have been R/I inspection
|
MEC20-00098
| Rough-in | 6/30/2020 | 6/30/2020 | 6/30/2020 12:08:54 PM | P | PASS |
|
|
Building 12 final re-inspection Phone #: ###-#### Inspection requested via web by Amanda Casper- framing 6 fire dampers clearances with sheetrock ok- ok fo install sleeve with fire damper and install with angle- went over with Dan onsite
|
MEC20-02656
| Final | 6/29/2020 | 6/30/2020 | 6/30/2020 11:21:12 AM | A | PASS |
|
|
PLEASE CALL HOMEOWNER ROB WHEN 30-40 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery- furnace a/c coil co locking caps ok
|
MEC20-01454
| Final | 6/30/2020 | 6/30/2020 | 6/30/2020 10:54:19 AM | A | PASS |
|
|
corrections made- pics sent via text
|
MEC20-02602
| Final | 6/25/2020 | 6/30/2020 | 6/30/2020 10:49:07 AM | A | PASS |
|
|
PLEASE CALL HOMEOWNER KIRK WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery- furnace a/c coil co locking caps ok
|
MEC20-01485
| Rough-in | 6/29/2020 | 6/30/2020 | 6/30/2020 10:12:38 AM | A | PART |
|
|
duct sealer inspection - call david Phone #: ###-#### Inspection requested via web by Brandon Sorensen- seal on all duct ok- will need to see supply and return mains off RTU 8 when installed- need verification on relief dampers in existing units if there being used or capped off- need hard lid inspection on restrooms
|
MEC20-02547
| Final | 6/29/2020 | 6/30/2020 | 6/30/2020 9:48:57 AM | A | PASS |
|
|
final - call david Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok- card signed
|
MEC20-02494
| Final | 6/30/2020 | 6/30/2020 | 6/30/2020 9:32:48 AM | A | PASS |
|
|
locking caps installed- pics sent via text
|
MEC20-02410
| Pressure Test | 6/26/2020 | 6/30/2020 | 6/30/2020 9:19:16 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass tagged meter location- 5lb flue pass
|
MEC20-02410
| Rough-in | 6/26/2020 | 6/30/2020 | 6/30/2020 9:18:43 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- R/I ok
|
MEC20-02411
| Pressure Test | 6/26/2020 | 6/30/2020 | 6/30/2020 9:18:28 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- 20lb gas pass tagged meter location- 5lb flue pass
|
MEC20-02411
| Rough-in | 6/26/2020 | 6/30/2020 | 6/30/2020 9:17:56 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- need to seal boots to floor and all spot welds on boots
|
MEC20-01462
| Final | 6/29/2020 | 6/30/2020 | 6/30/2020 9:00:02 AM | A | PASS |
|
|
CONTRACTOR WORKING ON SITE Phone #: ###-#### Inspection requested via web by Aaron Alandt- final ok
|
MEC20-02552
| Final | 6/29/2020 | 6/30/2020 | 6/30/2020 8:52:13 AM | A | FAIL |
|
|
Please call in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace a/c coil locking caps ok- need to add gas pressure test to permit and pay fee- need to provide co detector upstairs near bedroom- send pic for reinspect
|
MEC20-02552
| Pressure Test | 6/29/2020 | 6/30/2020 | 6/30/2020 8:50:50 AM | A | PASS |
|
|
Please call in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout- 20lb gas pass
|
MEC20-02058
| Final | 6/25/2020 | 6/30/2020 | 6/30/2020 8:36:38 AM | A | PASS |
|
|
Customer is requesting an AM apt and a courtesy call prior to arrival. Thank You. Phone #: ###-#### Inspection requested via web by Shari Wetzler- a/c coil co locking caps ok
|
MEC20-02011
| Rough-in | 6/30/2020 | 6/30/2020 | 6/30/2020 7:55:17 AM | A | PART |
|
|
pics sent of insulation above hard lid hallway- ok to cover
|
MEC20-02405
| Rough-in | 6/25/2020 | 6/30/2020 | 6/26/2020 3:26:04 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
|
MEC20-02405
| Pressure Test | 6/25/2020 | 6/30/2020 | 6/26/2020 3:26:02 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
|
MEC20-02406
| Rough-in | 6/25/2020 | 6/30/2020 | 6/26/2020 3:24:51 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
|
MEC20-02406
| Pressure Test | 6/25/2020 | 6/30/2020 | 6/26/2020 3:24:49 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
|