Inspections for the day of: Friday, July 10, 2020.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-02818 Final7/9/20207/10/20207/10/2020 3:24:14 PMPFAIL
Please inspect PM and call our installed Zach on your way for a video inspection. ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- a/c coil co locking caps ok- need electrical permit issued for relocation to final this permit out
MEC20-02829 Rough-in7/10/20207/10/20207/10/2020 3:05:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Dan Otero- fireplace R/I ok
MEC20-02738 DOC - Permit Finaled7/10/20207/10/20207/10/2020 2:54:03 PMPPASS
co installed
MEC20-02738 Pressure Test7/6/20207/10/20207/10/2020 2:53:04 PMPPASS
PLEASE CALL WHEN ON THE WAY. THANK YOU Phone #: ###-#### Inspection requested via web by SARA GREENHALGH- 20lb gas pass- 2 valves open tee installed at meter location
MEC20-02810 Final7/9/20207/10/20207/10/2020 2:36:07 PMPPASS
Please inspect PM and call our installed Jeremy on your way for a video inspection. ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks- furnace a/c coil co locking caps ok
MEC20-02765 Final7/6/20207/10/20207/10/2020 2:01:48 PMPCANC
Field super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney- due to COVID 19 we can no longer enter into occupied dwellings- no date set to return at this time- please reschedule accordingly- talked with Chad by phone about this
MEC20-02528 Rough-in7/10/20207/10/20207/10/2020 1:16:08 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak- access platform stills installed 24 inches wide and 30x30 in front of unit- need framing around exhaust completed- went over oinsite with Andrey
MEC20-02526 Rough-in7/10/20207/10/20207/10/2020 1:01:11 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak- access platfornma and access needs installed 24 inch wide and 30x30 in front of mini split- went over with Andrey onsite
MEC20-02509 Rough-in7/10/20207/10/20207/10/2020 1:00:20 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak- access platform still needs installed 24 inches wide with 30x30 access in front- went over with Andrey
MEC20-02535 Rough-in7/10/20207/10/20207/10/2020 12:59:35 PMPNR
Phone #: ###-#### Inspection requested via web by Oleg Chervak- framing needs completed for platform- went over onsite with Andrey
MEC20-02534 Rough-in7/10/20207/10/20207/10/2020 12:59:01 PMPNR
Phone #: ###-#### Inspection requested via web by Oleg Chervak- framing needs completed for platform- met with Andrey
MEC20-02745 Final7/6/20207/10/20207/10/2020 12:18:55 PMPPASS
INSTALLER GERRY ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace only
MEC20-02800 Final7/9/20207/10/20207/10/2020 12:01:49 PMPPASS
Furnace in garage. Homeowner Seth Bandurraga ###-####x7090 Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co locking caps ok
MEC20-01067 Final7/9/20207/10/20207/10/2020 11:27:59 AMPCANC
KAREN DUNN ###-#### Phone #: ###-#### >> Inspection requested via web by Mike Almanza Inspection cancelled from web by: Mike Almanza
MEC20-01067 Rough-in7/9/20207/10/20207/10/2020 11:27:57 AMPCANC
KAREN DUNN ###-#### Phone #: ###-#### >> Inspection requested via web by Mike Almanza Inspection cancelled from web by: Mike Almanza
MEC20-01734 Rough-in7/9/20207/10/20207/10/2020 11:25:14 AMAFAIL
Phone #: ###-#### Inspection requested via web by Konrad Swartz
1- flue test in garage failed at zero-
2- need to fix all rips and tear in arma flexboth units bare copper showing mulitple places and secure in wall in garage-
3- missing seal on range duct at exterior penetration
4- furnace in garage needs 6" OSA rsn per man j
5- fireplace needs permited and installed and gas line into appliance- no permit for this not sure whos doing
6- supply ducts to master, bedroom 3 and loft will be smashed by sheetrock and light fixtures installed under bonus room reroute individually
7- all boots need seal inside on return and supply
8- need access platforn to furnace in attic 24 inch wide and 30 inch working area in front of furnace in attic and unobstructed
9- need filter installed in return air furnace in attic or 6" OSA will need filtered
10- dryer duct needs nail plate back wall at ceiling and seal termination box to duct
11- flues need nail plates second floor and 1/4" per foot grade under bonus room in between joists has traps in it

left notice front window
MEC20-01734 Pressure Test7/9/20207/10/20207/10/2020 11:16:58 AMAFAIL
Phone #: ###-#### Inspection requested via web by Konrad Swartz- 20lb gas pass tagged meter location- 5lb flue in garage failed at zero
MEC20-00501 Rough-in7/9/20207/10/20207/10/2020 10:20:49 AMAPART
sealer inspection for attic area Phone #: ###-#### Inspection requested via web by Brandon Sorensen- seal on return and exhaust in attic ok- ok to insulate- 4 exhaust fans ok to cover hard lids
MEC20-02222 Rough-in7/9/20207/10/20207/10/2020 9:45:05 AMAPART
duct seal inspection Phone #: ###-#### Inspection requested via web by Robin Cox- seal on supply and return ducting ok- ok to insulate- need to see exhaust duct tied into hard lids before covered- call in when hard lids ready
MEC20-02806 Final7/9/20207/10/20207/10/2020 9:11:05 AMAFAIL
Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING- a/c coil locking caps ok- need to provide co detector near bedroom/s- send pic for reinspect- talked to Sophia about this by phone
MEC20-02148 Final7/6/20207/10/20207/10/2020 8:50:04 AMACANC
Call Richard ###-#### when in route to inspection Phone #: ###-#### Inspection requested via web by Justin Osterhout- per phone call with Rich no one available to do inspection- he will reschedule with contractor for day that works
MEC20-02712 Final7/9/20207/10/20207/10/2020 8:40:17 AMAPASS
CHAD ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps gas piping ducting in crawl(pics sent via text) ok
MEC20-01236 Rough-in7/9/20207/10/20207/10/2020 8:28:16 AMAPART
Please contact John Burks prior to arrival for access. Masks are required on this project. thanks. Phone #: ###-#### Phone #: ###-#### Inspection requested via web by Nicholas Paige- Phase 1 seal all ducts, registers and flex ok- ok for ceiling tiles all phase 1 area
MEC19-04095 Mec-Aging Inspection7/10/20207/10/20207/10/2020 7:40:47 AM CANC
permit expired
MEC19-04095 DOC - Permit Expired7/10/20207/10/20207/10/2020 7:40:34 AMAPASS
no calls- permit expired